
Hammond Power TN2D0002KDKA Three Phase 2kVA 480-240V Copper Windings 60Hertz 130C Type 4
UPC: 803423152338
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- The transformer core and coil is completely encapsulated in epoxy and silica, providing excellent protection from airborne contaminants and prevents the ingress of moisture.
- The three phase design has a removable hinged door and factory installed grounding lugs, reducing installation time and money.
- HPS Series of harsh environment transformers is available in two lines: cULus Listed – approved for applications requiring UL and/or CSA certifications; IECEx, ATEX, UKEx Certified – approved for applications requiring IEC conformity
- 130°C Insulation Class
- Type 4 Non-Ventilated Enclosure
Specifications
Application | Petrochemical, Marine, Industrial, Oil & gas, Mining, Waste Water |
Color | Blue |
Design | Encapsulated |
Enclosure | DQT1 |
Frequency | 60 Hz |
Frequency Rating | 60 HZ |
Height | 13.18 in |
Input Voltage | 480D V |
Insulation Class | 130 C |
KVA Rating | 2 |
Length | 12.26 in |
Material | Copper |
Mounting | Wall or Floor |
Nema Rating | Type 4 |
Number Of Phases | 3 |
Output Voltage | 240D V |
Poles | 3-Phase |
Poles | 3P |
Series | HPS TN2D Series |
Series | HPS |
Series | TN2D |
Special Features | Rugged encapsulated construction for use in harsh environments comes standard with ABS(American Bureau of Ships) and Class 1, Div. II, Groups A, B, C and D ratings |
Standard | cUL, Class 1 Div II |
Temperature Rating | Typical 40 Average/50 Maximum C |
Type | Transformer > Distribution > Encapsulated > Hazardous Location > Three Phase |
Voltage Rating | 480-240 VAC |
Voltage Rating | 480-240V |
Wattage | 2 KVA |
Width | 8.8 in |
Wiring Configuration | Delta - Delta |
Package Dimensions (L x W x H) | 9.13 IN x 13.13 IN x 13.38 IN |
Package Dimensions (L x W x H) | 23.1902 cm x 33.3502 cm x 33.9852 cm |
Package Weight (Imperial) | 74.000 L |
Package Weight (Metric) | 33.566 kg |
Frequently Asked Questions
What hazardous locations are these transformers approved for?
They are approved for Class 1, Division 2, Groups A, B, C, D and Class 1, Zone 2, Group IIC, T3 Hazardous Locations.
What is the standard enclosure type for three-phase units?
The standard enclosure type for three-phase units is a heavy-duty enclosed Type 4, which also meets Type 12.
What is the standard enclosure type for single-phase units?
The standard enclosure type for single-phase units is a heavy-duty enclosed Type 3R.
What is the warranty period for HPS Titan N transformers?
The warranty period for HPS Titan N transformers is 10 years.
What is the insulation system for single-phase units up to 1 kVA?
The insulation system is 130°C (80°C rise) for single-phase units up to 1 kVA.
What is the insulation system for single-phase units from 1.5 to 37.5 kVA?
The insulation system is 180°C (115°C rise) for single-phase units from 1.5 to 37.5 kVA.
What is the BIL rating for three-phase units?
The standard BIL rating for three-phase units is 10 kV.
What is the maximum kVA for single-phase HPS Titan N transformers?
The maximum kVA for single-phase HPS Titan N transformers is up to 37.5 kVA.
What is the maximum kVA for three-phase HPS Titan N transformers?
The maximum kVA for three-phase HPS Titan N transformers is up to 150 kVA.
What are the temperature codes for HPS Titan N transformers?
Temperature codes include T3C (80°C & 95°C rise units) and T3A (115°C rise units) at 40°C ambient.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.




