Hammond Power TN2A0045KHKF Three Phase 45kVA 480 -400Y/231V °Copper Windings 60Hertz 180°C Type 4 Enclosure
UPC: 803423151218
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- The transformer core and coil is completely encapsulated in epoxy and silica, providing excellent protection from airborne contaminants and prevents the ingress of moisture.
- The three phase design has a removable hinged door and factory installed grounding lugs, reducing installation time and money.
- HPS Series of harsh environment transformers is available in two lines: cULus Listed – approved for applications requiring UL and/or CSA certifications; IECEx, ATEX, UKEx Certified – approved for applications requiring IEC conformity
Specifications
Application | Petrochemical, Marine, Industrial, Oil & gas, Mining, Waste Water |
Connection Type | Wye (Y) |
Connection Type | 480-400Y/231 |
Design | Encapsulated |
Enclosure | DQT6 |
Frequency | 60Hz |
Frequency Rating | 60 HZ |
Height | 21.81 in |
Input Voltage | 480D V |
Insulation Class | 180 C |
KVA Rating | 45 |
Length | 25.06 in |
Material | Copper |
Mounting | Floor |
Nema Rating | Type 4 |
Number Of Phases | 3 |
Output Voltage | 400Y/231 V |
Poles | 3-Phase |
Poles | 3 |
Series | TN2A |
Special Features | Rugged encapsulated construction for use in harsh environments comes standard with ABS(American Bureau of Ships) and Class 1, Div. II, Groups A, B, C and D ratings |
Standard | cUL, Class 1 Div II |
Temperature Rating | Typical 40 Average/50 Maximum C |
Type | Transformer > Distribution > Encapsulated > Hazardous Location > Three Phase |
Voltage Rating | 480 to 400Y/231 V |
Voltage Rating | 480-400Y/231 VAC |
Voltage Rating | 480V to 400Y/231V |
Voltage Rating | 480-400Y/231V |
Wattage | 45 kVA |
Width | 17.74 in |
Wiring Configuration | Delta - Wye |
Package Dimensions (L x W x H) | 19.75 IN x 26.13 IN x 21.88 IN |
Package Dimensions (L x W x H) | 50.165 cm x 66.3702 cm x 55.5752 cm |
Package Weight (Imperial) | 635.000 L |
Package Weight (Metric) | 288.036 kg |
Frequently Asked Questions
What hazardous locations are these transformers approved for?
They are approved for Class 1, Division 2, Groups A, B, C, D and Class 1, Zone 2, Group IIC, T3 Hazardous Locations.
Are these transformers suitable for marine applications?
Yes, they have ABS Type Approval for Marine Duty Service and Offshore Applications.
What is the warranty period for HPS Titan transformers?
The HPS Titan transformers come with a 10-year warranty.
How are the transformers protected from environmental factors?
The core and coil are completely encapsulated in epoxy and silica, protecting from contaminants and moisture ingress.
What is the BIL rating for the three-phase units?
The three-phase units have a standard 10kV BIL rating for increased reliability and protection against critical equipment failure.
What type of enclosure is standard for three-phase units?
Three-phase units come with a standard Type 4 enclosure, which is suitable for indoor or outdoor applications.
What is the maximum kVA for single-phase units?
Single-phase units are available up to 37.5kVA.
What is the maximum kVA for three-phase units?
Three-phase units are available up to 150kVA.
What is the standard frequency for these transformers?
The standard frequency is 60 Hz, with 50/60Hz options available for some models.
What are the mounting options for three-phase units?
Three-phase units offer floor or wall/ceiling mounting, with integral brackets on select kVA sizes.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.