Authorized Hammond Power Distributor
Hammond Power TE3A0145NG - 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 575D-380Y/220V AL 60Hz 3R

Hammond Power TE3A0145NG 600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive…

UPC: 803423143992


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power TE3A0145NG is a 145kVA, three-phase drive isolation transformer designed for energy efficiency and compliance with DOE2016 and NRCan 2019 standards. This transformer operates with a primary voltage of 575D and a secondary voltage of 380Y/220V at 60Hz. Its robust construction ensures reliable performance in industrial settings. The TE3A0145NG is engineered to provide a clean and stable power source for variable frequency drives (VFDs) and other sensitive motor control equipment, helping to mitigate electrical noise and voltage fluctuations. This unit is manufactured in the USA and features an aluminum winding for efficient power transfer. Its 3R enclosure provides protection against environmental factors. By utilizing this energy-efficient transformer, facilities can reduce operational costs and meet stringent energy regulations. The SKU TE3A0145NG signifies a commitment to quality and performance in power distribution solutions. This transformer is ideal for applications requiring precise voltage regulation and protection for motor control systems, contributing to extended equipment lifespan and reduced maintenance. Its compliance with current energy efficiency mandates makes it a forward-thinking choice for modern industrial infrastructure.
  • 145kVA Three-Phase Drive Isolation Transformer
  • 600V Class, 575D Primary / 380Y/220V Secondary
  • DOE2016 and NRCan 2019 Compliant
  • Energy Efficient with Aluminum Winding
  • 3R Enclosure for Industrial Environments

Specifications

Application
Variable Speed Drives.
Current Rating
145kVA
Efficiency
NRCan 2018 Energy Efficient
Enclosure
DH4-N3R - Indoor or Outdoor
Enclosure Colour
ANSI 61 Grey, UL50
Enclosure Type
3R
Frequency
60Hz
Frequency
60 Hz
Frequency Rating
60 HZ
Height
44.5 in
Height
1130.3 mm
Insulation Class
220 Deg C Class
Ip Rating
3R
KVA Rating
145 KVA
Length
29.5 in
Length
749.3 mm
Material
Al
Mounting
Floor Mount
Mounting Method
Floor
NEMA Frame Size
Type 3R
NEMA Rating
3R
Number Of Phases
3
Phase
3PH
Poles
3
Primary Voltage
575D V
Secondary Voltage
380Y/220V
Series
TE3A
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets NRCan 2018 efficiencies and designed to meet rugged demands of both AC and DC variable speed drives and alos to provide the required voltage change. Comes standard in an outdoor enclosure and a thermal warning switch.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150 °C
Transformer Rating
145kVA
Type
Transformers > Drive Isolation > NRCan 2018 Energy Efficient
Voltage Rating
575D-380Y/220V
Wall Mounting
No
Warranty
10 year warranty
Weight
900 L
Width
31.5 in
Width
800.1 mm
Winding
Aluminum
Package Dimensions (L x W x H)
29.5 IN x 31.5 IN x 44.5 IN
Package Dimensions (L x W x H)
74.93 cm x 80.01 cm x 113.03 cm
Package Weight (Imperial)
900.000 L
Package Weight (Metric)
408.240 kg
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 460D-460Y/266V AL 60Hz 3R

TE3A0145JJ

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 145kVA 460D-460Y/266V AL 60Hz 3R
Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561

DT651H93S

Drive Isolation Transformer, 93 kVA, Drive Horse Power 75, 460 Delta Primary, 460Y/266 Secondary, 60 HZ , cULus Listed: E7014, UL 506, CSA C22.2No.66, UL Listed E25872, UL1561
ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.

9T10A1004G63

ABB's Guard I&trade, Noise Isolation Transformers provide common mode noise signal between neutral and ground and transverse mode noise protection. Common mode noise is caused by electromagnetic interference, radio interference and ground loops.
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 220kVA 480D-380Y/220 V AL 60Hz 3R

TE3A0220KG

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 220kVA 480D-380Y/220 V AL 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 480D-380Y/220 V CU 60Hz 3R

TE3A0550KGM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 480D-380Y/220 V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V CU 60Hz 3R

TE3A0020KKM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 20kVA 480D-480Y/277 V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 460D-460Y/266V CU 60Hz 3R

TE3A0550JJM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 550kVA 460D-460Y/266V CU 60Hz 3R
600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-480Y/277 V CU 60Hz 3R

TE3A0660KKM

600V Class Three Phased DOE2016 and NRCan 2019 Compliant Energy Efficient Drive Isolation Transformer 660kVA 480D-480Y/277 V CU 60Hz 3R

Frequently Asked Questions

What is the insulation system and temperature rise for HPS Tribune E transformers?

All units utilize a uniform 220°C insulation system with options for 80°C, 115°C, or 150°C temperature rise.

What is the standard enclosure type for HPS Tribune E transformers?

The standard enclosure is a heavy duty ventilated Type 3R, suitable for indoor or outdoor applications.

What are the mounting options for HPS Tribune E transformers?

Floor or wall/ceiling mounting is available. Integral floor and wall mounting brackets are standard up to 45kVA.

What is the standard BIL rating for HPS Tribune E transformers?

The standard BIL rating is 10kV, providing increased reliability and protection against voltage spikes and transients.

What conductor materials are available for HPS Tribune E transformers?

The transformers are available with either copper or aluminum conductors.

What are the dimensions for a 145 kVA unit with 575V primary?

A 145 kVA unit with a 575V primary has dimensions of 31.50 inches width, 29.50 inches depth, and 44.50 inches height.

What is the typical impedance range for HPS Tribune E transformers?

The typical impedance range is between 1.8% to 7.5%.

What frequency options are available for HPS Tribune E transformers?

The standard frequency is 60 Hz, with an optional 50/60 Hz available.

What are the K-Rating considerations for HPS Tribune E transformers?

K-Rating sizing allows for motor efficiency and 6 Pulse Drive Harmonics, with a K=13 rating.

What is the warranty period for HPS Tribune E transformers?

The HPS Tribune E transformers come with a 10-year warranty.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.