Hammond Power SP350KHP General Purpose Open-Style Core & Coil Control Transformers, 380/347 PV, 120x240 SV, 350…
UPC: 803423099091
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 350 kVA General Purpose Open-Style Control Transformer
- Primary Voltage: 380/347V
- Secondary Voltage: 120x240V
- Manufactured by Hammond Power in the USA
- Ideal for industrial and light-duty loads
Specifications
Application | HVAC, signals and alarm systems, motor control circuits, lighting and circuit isolation |
Enclosure | Core and Coil |
Frequency Rating | 50 HZ |
Height | 3.4 IN |
Length | 3.78 in |
Mounting | Panel |
Series | HPS Spartan™ |
Special Features | Control transformer for stanard commercial loads without high current inrush, optional finger safe covers are available. |
Standard | csa, ul, ce |
Temperature Rating | Typical 30 Average/ 40 Maximum Deg C |
Type | Tranformer > Dry Type > Control > Open Core and coil |
Voltage Rating | 380/347 PV, 120x240 SV |
Wattage | 350 VA |
Width | 4.69 in |
Package Dimensions (L x W x H) | 3.78 IN x 4.69 IN x 3.4 IN |
Package Dimensions (L x W x H) | 96 mm x 119.13 mm x 86.36 mm |
Package Weight (Imperial) | 8.400 L |
Package Weight (Metric) | 3.800 kg |
Frequently Asked Questions
What are the key features of the HPS Spartan industrial control transformer?
Key features include multi-voltage primaries/secondaries, solid terminal blocks, copper wound coils, bolted core construction, and seismic qualification.
What insulation systems are available for HPS Spartan transformers?
Insulation systems include 130°C (80°C rise) for up to 1500 VA and 180°C (115°C rise) for 2000 VA to 5000 VA units.
Are optional accessories available for HPS Spartan transformers?
Yes, optional finger guards and fuse block adapter kits are available for units up to 3000VA or 30 amps.
What is the warranty period for HPS Spartan transformers?
The HPS Spartan series of industrial control transformers comes with a 15-year warranty.
What approvals does the HPS Spartan transformer meet?
The transformer meets NEMA standards, is CSA Certified, UL Listed, and CE Marked.
What are the operating frequencies for HPS Spartan transformers?
The transformers operate at 50/60 Hz, with specific models (SP***ACP and SP***AR) operating at 60 Hz.
Are primary and secondary voltage links/jumpers included?
Yes, primary and secondary voltage links/jumpers are supplied standard with all transformers in the HPS Spartan series.
What are the available primary and secondary voltages for Group F transformers?
Group F transformers have primary voltages of 380/347 and secondary voltages of 12 x 24.
What are the available primary and secondary voltages for Group H transformers?
Group H transformers have primary voltages of 120 x 240 and secondary voltages of 12 x 24.
What are the seismic qualification design parameters for this transformer?
Seismic qualification is according to IBC 2018 and ASCE 7-10 with SDS <= 2.0g, IP = 1.5, and z/h = 1.0”.
How to Install the SP350KHP Industrial Control Transformer
This guide provides step-by-step instructions for the installation and initial setup of the SP350KHP Industrial Control Transformer, including wiring and configuration.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the transformer
Secure the transformer to the mounting surface using appropriately sized mounting screws. Ensure that the transformer is level and securely attached.
- Connect the voltage links and jumpers
Install the voltage link kit and jumper kits as per the provided wiring instructions. Ensure all connections are tight and secure.
- Wire the transformer
Use the recommended wire sizes (18 AWG to 14 AWG for solid wire and 18 AWG to 12 AWG for stranded wire) to connect the primary and secondary terminals. Use ring or spade connectors for wires outside the specified range.
- Torque terminal screws
Torque all terminal screws to a specification of 12 to 14 inch-lbs to ensure proper electrical connection.
- Install optional accessories
If using the optional Fuse Block Adapter Kit, remove the appropriate captive washer screws from the terminal block and use them to install the aftermarket fuse block onto the fuse block adapter plate.
- Verify connections
Use a multimeter to verify that all connections are correct and that there are no short circuits before powering on the transformer.
- Calibrate the transformer
Follow the calibration procedures outlined in the product manual to ensure the transformer operates within specified parameters.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.