- 100 kVA rated capacity for industrial control applications
- Selectable primary voltages: 208V or 416V; secondary voltages: 120V or 240V
- Open-style construction for efficient heat dissipation
- Single-phase, common core design with copper wound coils
- Supports linear loads at 60Hz or 50Hz system frequencies
Specifications
Application | HVAC, signals and alarm systems, motor control circuits, lighting and circuit isolation |
Enclosure | Core and Coil |
Frequency Rating | 50/60 HZ |
Height | 2.85 in |
Length | 2.99 in |
Mounting | Panel |
Special Features | Control transformer for stanard commercial loads without high current inrush, optional finger safe covers are available. |
Standard | csa, ul, ce |
Temperature Rating | Typical 30 Average/ 40 Maximum Deg C |
Type | Tranformer > Dry Type > Control > Open Core and coil |
Wattage | 100 VA |
Width | 3.54 in |
Package Dimensions (L x W x H) | 2.99 IN x 3.54 IN x 2.85 IN |
Package Dimensions (L x W x H) | 75.95 mm x 89.92 mm x 72.39 mm |
Package Weight (Imperial) | 3.000 L |
Package Weight (Metric) | 1.400 kg |
Frequently Asked Questions
What standards does the HPS Spartan transformer meet?
The HPS Spartan transformer meets NEMA standards, is CSA Certified, UL Listed, and CE Marked.
What are the insulation system temperature ratings?
It offers a 130°C (80°C rise) insulation system up to 1500 VA, and 180°C (115°C rise) from 2000 VA to 5000 VA.
What is the frequency range for this transformer?
The transformer operates at 50/60 Hz, with specific models (SP ***ACP and SP ***AR) operating at 60 Hz.
Are voltage links/jumpers included with the transformer?
Yes, all units are supplied with primary and secondary voltage links/jumpers.
What is the warranty period for the HPS Spartan transformer?
The HPS Spartan series industrial control transformers come with a 15-year warranty.
What are the seismic qualification design parameters?
It is seismically qualified according to IBC 2018 and ASCE 7-10 with SDS <= 2.0g, IP = 1.5, and z/h = 1.0”.
What optional accessories are available for this transformer?
Optional accessories include finger guards and fuse block adapter kits for units up to 3000VA or 30 amps.
What is the construction of the coils?
The transformer features copper wound coils with high dielectric strength insulation and is vacuum impregnated with polyester resin.
Are custom control transformers available?
Yes, HPS offers custom control transformers to meet specific design style requirements for various applications.
What is the purpose of the Fuse Block Adapter Kit?
The kit allows installation of third-party fuse blocks onto transformers with molded terminal blocks, up to 3000VA or 30 amps.
How to Install the Open Core & Coil Industrial Control Transformer
This guide provides step-by-step instructions for installing and wiring the Open Core & Coil Industrial Control Transformer, including optional accessories.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Fuse block adapter kit (optional), Finger guard kit (optional)
- Mount the transformer
Secure the transformer to the mounting surface using appropriately sized mounting screws. Ensure that the mounting hardware is suitable for the weight of the transformer.
- Connect the voltage links and jumpers
Install the voltage link kit and jumper kits as per the wiring instructions provided with the transformer. Ensure all connections are tight and secure.
- Install optional accessories
If using the optional Fuse Block Adapter Kit, remove the appropriate captive washer screws from the terminal block and use them to install the fuse block onto the adapter plate. If using the Finger Guard Kit, mount it on the transformer according to the provided instructions.
- Verify electrical connections
Use a multimeter to check all connections for continuity and proper voltage levels. Ensure that all terminal screws are torqued between 12 to 14 inch-lbs.
- Calibrate the transformer
Follow the calibration procedures outlined in the transformer’s manual to ensure proper operation. Adjust settings as necessary based on the application requirements.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.