Contact for Pricing
Overview
- Specifically designed to handle the harmonics generated by non-linear loads such as computer and telecommunication equipment, drives and other power electronics
- Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12; Mexico - NMX-J-351-ANCE-2021
- Standard three phase voltage groups available at k-factor ratings of K4, K9, K13
- Copper-wound design for lower losses and higher efficiency compared to aluminum alternatives
- Shielded construction to protect against electrical noise and interference
Specifications
Application | Addresses the overheating problems due to harmonics associated with non-linear loads where drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations. |
Cable Entry | Side knock-outs standard on all units |
Cooling | Convection cooled |
Depth | 41.5 IN |
Enclosure | DH6-N3R - Indoor or Outdoor |
Enclosure Color | ANSI 61 Grey |
Enclosure Type | 3R |
Frequency | 60 Hz |
Frequency Rating | 60 HZ |
Height | 64 IN |
KVA Rating | 750 KVA |
Length | 41.5 IN |
Mounting | Floor Mount |
Mounting Method | Floor |
Number Of Phases | 3 |
Number Of Taps | ST-20 compliant |
Phase | A - 3PH Delta-Wye-N |
Phase | 3PH |
Primary Voltage | 600D V |
Secondary Voltage | 208Y/120V |
Sound Level dBA | Meets NEMA ST-20 standards |
Special Features | Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs. |
Standard | CSA, UL |
Temperature Rating | Typical 30 Average/ 40 Maximum Deg C |
Temperature Rise | 150 |
Transformer Rating | 750kVA |
Type | Transformer > Distribution > DOE 2016 Energy Efficient > K Factor > Three Phase |
Wall Mounting | No |
Warranty | 10 year warranty |
Weight | 4400 lbs |
Width | 49 IN |
Winding | K - CU + Shield |
Winding | CU |
Package Dimensions (L x W x H) | 41.5 IN x 49 IN x 64 IN |
Package Dimensions (L x W x H) | 105.41 cm x 124.46 cm x 162.56 cm |
Package Weight (Imperial) | 4400.000 L |
Package Weight (Metric) | 1995.840 kg |

SK3A0750PB4K
600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 4, 600D PV, 208Y/120 SV, 750 kVA, Three Phase, Copper Wound, Shielded
E2HB300S
SolaHD, Ventilated Distribution Transformer, DOE 10 Cfr P431 - DOE 2016 Compliant, Ul Listed E25872, 300 KVA, Primary Voltage 480 V, Secondary Voltage 208 V, 60 HZ, 3 Phase, Number Of Taps 7, Temperature Rating 80 Degrees C, Connection Delta-Wye, Winding Aluminium, Enclosure Nema Type 1
9T10A1313
ABB Low-Voltage General Purpose Dry-Type transformers are built to last more than 20 years and are UL Listed. Our Type QL & QF transformers meet DOE 2016 efficiency standards and are UL Energy Verified as energy efficient. They are available with aluminum or copper windings and in all three temperature rise ratings. Quiet Performance-Core and coil assemblies are mounted on rubber isolation pads to reduce noise. Single-piece front/back is easily removable for installation and service. Qualified to the seismic requirements of IEEE-693-2005 and IBC-2021 and CBC 2022.
CEA 2-50
Tin-Plated Copper Overhead Transformer Eyebolt Adapter, pin diameter 1/2, exposed pin size 2-5/8 inchFrequently Asked Questions
What efficiency standards does this transformer meet?
This transformer meets DOE 2016 and NRCan 2019 energy efficiency standards for distribution transformers.
What is the standard enclosure type?
The standard enclosure is a heavy-duty ventilated Type 3R, suitable for indoor or outdoor applications.
What insulation system does the transformer use?
The transformer uses a 220°C insulation system with temperature rise options of 80°C, 115°C, or 150°C.
What is the standard warranty period?
Hammond Power Solutions provides a 10-year warranty for these transformers.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.