Authorized Hammond Power Distributor
Hammond Power SK3A0500KK9S - 600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor Transformer, K-Factor 9, 480D PV, 480Y/277 SV, 500 kVA, Three Phase, Aluminum Wound, Shielded
More images

Hammond Power SK3A0500KK9S 600V Class Three Phase DOE2016 and NRCan 2019 Compliant Energy Efficient K-Factor…

UPC: 803423129859


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power SK3A0500KK9S is a 500 kVA, three-phase, K-Factor 9 transformer designed for energy efficiency, meeting DOE2016 and NRCan 2019 compliance standards. This transformer features aluminum windings and a shielded design, making it an ideal solution for environments with harmonic distortion caused by non-linear loads. Its robust construction and compliance with energy efficiency regulations ensure reliable performance and reduced operating costs. The primary winding is rated for 480D PV, and the secondary winding for 480Y/277 SV, providing versatile application possibilities. Manufactured in the US, this transformer (SKU: SK3A0500KK9S) offers a dependable and efficient power solution for industrial and commercial applications requiring harmonic mitigation and energy savings. The K-Factor 9 rating specifically addresses the challenges posed by harmonic currents generated by electronic loads, protecting downstream equipment and ensuring system stability. Its shielded construction further enhances performance by minimizing electromagnetic interference. This unit is built to last and perform optimally in demanding electrical systems.
  • Specifically designed to handle the harmonics generated by non-linear loads such as computer and telecommunication equipment, drives and other power electronics
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12;  Mexico - NMX-J-351-ANCE-2021
  • Standard three phase voltage groups available at k-factor ratings of K4, K9, K13
  • Shielded Design for Harmonic Distortion Mitigation
  • Primary: 480D PV, Secondary: 480Y/277 SV

Specifications

Application
Addresses the overheating problems due to harmonics associated with non-linear loads where drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics are found in high concentrations.
Cable Entry
Side knock-outs standard on all units
Connection Type
Wye/Delta
Cooling
Convection cooled
Depth
41.5 IN
Enclosure
DH6-N3R - Indoor or Outdoor
Enclosure Color
ANSI 61 Grey
Enclosure Type
3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
64 in
Height
1625.6 mm
KVA Rating
500 KVA
Length
41.5 IN
Material
Aluminum
Mounting
Floor Mount
Mounting Method
Floor
Mounting Type
Shielded
Number Of Phases
3
Number Of Taps
ST-20 compliant
Phase
3PH
Phase
A - 3PH Delta-Wye-N
Poles
3P
Primary Voltage
480D V
Primary Voltage
480 VAC
Secondary Voltage
480Y/277V
Series
DOE2016/NRCan 2019 Compliant Energy Efficient K-Factor
Size
500 kVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150
Transformer Rating
500kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > K Factor > Three Phase
Voltage Rating
480 VAC
Wall Mounting
No
Warranty
10 year warranty
Weight
2850 lbs
Width
49 in
Width
1244.6 mm
Winding
AL
Winding
S - AL + Shield
Package Dimensions (L x W x H)
41.5 IN x 49 IN x 64 IN
Package Dimensions (L x W x H)
105.41 cm x 124.46 cm x 162.56 cm
Package Weight (Imperial)
2850.000 L
Package Weight (Metric)
1292.760 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

What is the insulation system temperature rating for HPS Sentinel Transformers?

All units utilize a uniform 220°C insulation system, with optional temperature rises of 80°C, 115°C, or 150°C.

What is the standard enclosure type for HPS transformers?

All HPS transformers come with a standard Type 3R enclosure, suitable for indoor or outdoor applications.

Are these transformers compliant with energy efficiency regulations?

Yes, the HPS Sentinel G, K, and H product lines meet the latest energy efficiency standards outlined by DOE and NRCan.

What is the standard BIL rating for HPS distribution transformers?

The standard BIL rating is 10 kV, providing increased reliability and protection against voltage spikes.

What mounting options are available for HPS Sentinel Transformers?

Floor or wall/ceiling mounting is available. Integrated floor and wall mounting brackets are standard on units up to 50kVA.

What is the warranty period for HPS Sentinel Transformers?

HPS Sentinel Transformers come with a 10-year warranty.

What types of loads are K-Factor transformers designed for?

K-Factor transformers are specifically designed to handle harmonics generated by non-linear loads like computer equipment and power electronics.

What is the purpose of Harmonic Mitigating Transformers (HMTs)?

HMTs are designed to treat harmonics by combining zero sequence flux cancellation with phase shifting to mitigate specific harmonic frequencies.

What are the dimensions for a 500 kVA, 208 Delta primary, 480Y/277 secondary transformer?

For a 500 kVA, 208 Delta primary, 480Y/277 secondary transformer (SG3A0500BK), the dimensions are 49.0 inches width, 42.0 inches depth, and 64.0 inches height.

What is the typical impedance range for these transformers?

The typical impedance for these transformers ranges from 1.8% to 7.5%.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.