Contact for Pricing
Overview
- HPS general purpose distribution transformers are rated for 600 volts and below.
- Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12; Mexico - NMX-J-351-1-ANCE-2021
- HPS also offers a line of low voltage Smart Transformers with integrated power monitoring for enhanced energy management and real-time performance insights.
- Suitable for general-purpose distribution in industrial/commercial applications
- Compact design for indoor installations
Specifications
Cable Entry | Knock Outs |
Connection Type | Screw Terminals |
Current Rating | 729 A (175kVA / 240V) |
Enclosure Color | ANSI 61 Grey, UL 50 |
Enclosure Type | Type 3R |
Frequency | 60 Hz |
Height | 64 in |
Height | 1625.6 mm |
Impedance | Typically 1.8% to 7.5% |
Insulation Class | 220°C |
Length | 49 in |
Length | 1244.6 mm |
Material | Copper |
Material | Copper Wound |
Mounting Method | Floor |
Mounting Type | Floor Mount |
Phase | 3PH |
Poles | 1PH |
Poles | Single Phase |
Primary Voltage | 480 VAC |
Secondary Voltage | 120/240V |
Series | SG3L Series |
Series | SG3L |
Series | DOE2016/NRCan 2019 Compliant |
Size | Large (175 kVA) |
Size | 175 kVA |
Sound Level dBA | Meets NEMA ST-20 standards |
Temperature Rise | 150°C |
Termination | Mechanical Lugs |
Transformer Rating | 60Hz |
Voltage Rating | 480-120/240 V |
Voltage Rating | 480 VAC / 120/240 VAC |
Voltage Rating | 480V (PV) / 120/240V (SV) |
Voltage Rating | 480V to 120/240V |
Wall Mounting | No |
Warranty | 10 year warranty |
Width | 39 in |
Width | 990.6 mm |
Winding | Copper |
Package Dimensions (L x W x H) | 31.5 IN x 29.5 IN x 44.5 IN |
Package Dimensions (L x W x H) | 800 mm x 749 mm x 1130 mm |
Package Weight (Imperial) | 925.000 L |
Package Weight (Metric) | 420.000 kg |
How to Install the SG3L0175KE0C Transformer
This guide provides step-by-step instructions for the installation and initial setup of the SG3L0175KE0C transformer, ensuring safe and efficient operation.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Grounding wire
- Inspect the transformer
Immediately after receiving the transformer, inspect it for any transit damage and ensure all parts are accounted for according to the shipping documents.
- Mount the transformer
Secure the transformer to a suitable surface using the provided mounting screws. Ensure it is installed in an upright position and in a location that allows for proper ventilation.
- Connect the grounding wire
Connect the grounding wire to the designated ground location on the transformer. Ensure that the connection is tight and complies with local electrical codes.
- Make electrical connections
Connect the primary and secondary cables to the transformer terminals as per the nameplate diagram. Use terminal connectors and ensure all connections are secure.
- Verify connections and settings
Before energizing the transformer, verify that all connections are correct and tight. Check that the load is balanced across all phases and that the transformer is properly grounded.
- Energize the transformer
Turn on the power supply to the transformer. Use a multimeter to measure and verify that the output voltage matches the specifications on the nameplate.
- Perform initial calibration
If applicable, perform any necessary calibration procedures as outlined in the manufacturer's instructions to ensure optimal performance.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.