Hammond Power SG3L0037BE0C - 600V Class Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 208 PV, 120/240 SV, 37.5 kVA, 1PH, Copper Wound
Hammond Power

SG3L0037BE0C

UPC: 803423140571


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The Hammond Power SG3L0037BE0C is a 37.5 kVA, single-phase, copper-wound distribution transformer designed for general-purpose power distribution. This unit is compliant with DOE2016 and NRCan 2019 energy efficiency standards, ensuring reduced energy consumption and operational costs. It features a primary voltage rating of 208 VAC and a secondary voltage rating of 120/240 VAC, making it suitable for a wide range of applications. Operating at a standard 60 Hz frequency, this transformer is ideal for supplying power to appliance, lighting, heating, motorized machine, and various other power loads from electrical distribution systems. The robust copper windings offer excellent conductivity and thermal performance, contributing to the transformer's reliability and longevity. Manufactured in the USA, the SG3L series transformers are built to meet stringent quality and performance requirements. This specific model, SKU SG3L0037BE0C, is a dependable choice for facilities requiring efficient and stable power conversion. Its design facilitates straightforward integration into existing electrical infrastructure, providing a secure and efficient power source for commercial and industrial settings. The transformer's compliance with current energy regulations underscores its commitment to sustainability and operational efficiency. Key specifications include a 37.5 kVA capacity, 1-phase operation, 208V primary, and 120/240V secondary, all within the reliable SG3L series from Hammond Power.
  • HPS general purpose distribution transformers are rated for 600 volts and below.
  • Meets North American Efficiency Standards: U.S. - DOE 10 CFR Part 431 (DOE 2016); Canada - SOR/2018-201, (NRCan 2019) & ON Reg. 404/12; Mexico - NMX-J-351-1-ANCE-2021
  • HPS also offers a line of low voltage Smart Transformers with integrated power monitoring for enhanced energy management and real-time performance insights.
  • 120/240 VAC secondary voltage
  • Copper wound for superior conductivity and reliability

Specifications

Application
General purpose for supplying appliance, lighting, motorized machine and power loads from electrical distribution systems.
Cable Entry
Knock Outs
Cooling
Convection cooled
Enclosure
NH6-N3R - Indoor or Outdoor
Enclosure Color
ANSI 61 Grey, UL 50
Enclosure Type
Type 3R
Frequency
60 Hz
Frequency Rating
60 HZ
Height
26.7 in
Impedance
Typically 1.8% to 7.5%
Insulation Class
220°C
KVA Rating
37.5 KVA
Length
23.8 IN
Material
Copper
Mounting
Floor or Wall mount
Mounting Method
Wall/Floor
Number Of Taps
ST-20 compliant
Phase
1PH
Phase
L- 1PH Single-Dual
Poles
1PH
Primary Voltage
208 V
Secondary Voltage
120/240V
Series
SG3L
Size
37.5 kVA
Sound Level dBA
Meets NEMA ST-20 standards
Special Features
Meets current DOE 10 CFR part 431 (2016) and C802.2 efficiencies in an outdoor type enclosure. Smaller kVA sizes have standard input and/or output lugs, knockouts, and wall mounting brackets to save installation costs.
Standard
CSA, UL
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Temperature Rise
150°C
Termination
Mechanical Lugs
Transformer Rating
37.5kVA
Type
Transformer > Distribution > DOE 2016 Energy Efficient > General Purpose > Single Phase
Voltage Rating
208 V / 120/240 V
Wall Mounting
Yes
Warranty
10 year warranty
Width
22.3 in
Winding
Copper
Winding
C - Copper
Package Dimensions (L x W x H)
23.8 IN x 22.3 IN x 26.7 IN
Package Dimensions (L x W x H)
60.452 cm x 56.642 cm x 67.818 cm
Package Weight (Imperial)
300.000 L
Package Weight (Metric)
136.080 kg
600V Class Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 208 PV, 120/240 SV, 15 kVA, 1PH, Copper Wound

SG3L0015BE0C

600V Class Single Phase DOE2016 and NRCan 2019 Compliant Energy Efficient Distribution Transformer, 208 PV, 120/240 SV, 15 kVA, 1PH, Copper Wound
Features:Wall Mounting Bracket (WB1C), Primary Amperage 62.5/31.3A, Secondary Amperage 125/62.5A, 220 DEG C Insulation System, Standard:UL, KVA Rating:15KVA, Primary Voltage:240/480V AC, Secondary Voltage:120/240V AC

ES5H15S

Features:Wall Mounting Bracket (WB1C), Primary Amperage 62.5/31.3A, Secondary Amperage 125/62.5A, 220 DEG C Insulation System, Standard:UL, KVA Rating:15KVA, Primary Voltage:240/480V AC, Secondary Voltage:120/240V AC
ABB's 9T33 Single phase low-voltage dry type transformers are for balanced 3-wire 120/240 V secondary voltage systems having both NRCan (C802.2) and DOE (10 CFR 431, Subpart K) energy efficiency certification and compliance. UL and cUL listed to UL 1561 and CSA C22.2 No.47. Qualified to the seismic requirements of IEEE-693-2005 and the IBC-2021 and CBC 2022. The 9T33 transformers are also UL Energy Verified.

9T33A2675

ABB's 9T33 Single phase low-voltage dry type transformers are for balanced 3-wire 120/240 V secondary voltage systems having both NRCan (C802.2) and DOE (10 CFR 431, Subpart K) energy efficiency certification and compliance. UL and cUL listed to UL 1561 and CSA C22.2 No.47. Qualified to the seismic requirements of IEEE-693-2005 and the IBC-2021 and CBC 2022. The 9T33 transformers are also UL Energy Verified.
REXPOWER 15KVA 3PH 60HZ NEMA 1

BA15C-P/Z3

REXPOWER 15KVA 3PH 60HZ NEMA 1
15 kVA Single-Phase Ventilated Transformer

421-9160-000

15 kVA Single-Phase Ventilated Transformer
Tin-Plated Copper Overhead Transformer Eyebolt Adapter, pin diameter 1/2, exposed pin size 2-5/8 inch

CEA 2-50

Tin-Plated Copper Overhead Transformer Eyebolt Adapter, pin diameter 1/2, exposed pin size 2-5/8 inch

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.