Overview
- 1000VA Machine Tool Rated Molded Industrial Control Transformer
- Primary and Secondary Voltages: 120x240V
- Encapsulated with electrical grade silica sand and resin compounds
- 180°C Insulation System (115°C rise)
- UL Listed (File: E50394) and CSA Certified (File: LR3902)
Specifications
Series | HPS Imperator™ |
Voltage Rating | 120x240 V |
Package Dimensions (L x W x H) | 5.25 IN x 6.81 IN x 4.94 IN |
Package Dimensions (L x W x H) | 133.35 mm x 172.98 mm x 125.48 mm |
Package Weight (Imperial) | 23.600 L |
Package Weight (Metric) | 10.700 kg |
Frequently Asked Questions
What is the VA range for the HPS Imperator series?
The HPS Imperator series offers a VA range from 50VA to 1500VA.
What standards do HPS Imperator transformers meet or exceed?
They meet or exceed UL, CSA, and CE standards.
What is the temperature rise for 50-150VA units?
For 50-150VA units, the temperature rise is 55°C with an insulation class of 130°C.
What is the temperature rise for 250-1500VA units?
For 250-1500VA units, the temperature rise is 80°C with an insulation class of 130°C.
What type of wire can be used with the serrated terminals?
The serrated terminals are suitable for 18 AWG to 14 AWG solid or 14 AWG stranded wire.
What size fuse clips are used for standard secondary fuse kits?
Standard secondary fuse kits utilize 13/32” x 1 1/2” midget/type CC fuse clips.
Are optional primary fuse kits available?
Yes, optional primary fuse kits are available, also utilizing 13/32” x 1 1/2” midget/type CC fuse clips.
What is the warranty for the HPS Imperator industrial control transformer?
The HPS Imperator industrial control transformer line is backed by a LIFETIME warranty (Limited).
What is the operating frequency for these transformers?
The transformers operate at 50/60 Hertz, with specific models (PH AJ & PH AR) operating at 60Hz.
What are the primary voltage options for Group E transformers?
Group E transformers have primary voltage options of 208 x 416, 200 x 400, and 190 x 380.
How to Install the HPS Imperator® Control Transformer
This guide provides step-by-step instructions for installing and configuring the HPS Imperator® Control Transformer, including mounting, wiring, and initial setup.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Fuse clips, Voltage links, Terminal connectors
- Mount the transformer
Secure the HPS Imperator® transformer to the designated mounting surface using appropriately sized mounting screws. Ensure the transformer is level and securely attached.
- Install fuse clips
Remove the appropriate captive washer screw(s) from the terminal block and install the fuse clip(s) using the new terminal screw(s) provided in the accessory kit.
- Connect voltage links
Install the voltage links between the primary or secondary terminal bays as indicated in the assembly drawings provided. Ensure all connections are secure and torque terminal screws to 12-14 inch-lbs.
- Verify connections
Use a multimeter to check all connections for continuity and ensure that there are no short circuits. Double-check that all wiring complies with the recommended wire size (18 AWG to 14 AWG for solid wire).
- Calibrate the transformer
Follow the calibration instructions provided in the PHWD1 or PHWD2 instruction sheet included with your transformer to ensure proper operation.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.