Hammond Power FS750KHP General Purpose Enclosed Control Transformer, 380/347 PV, 120x240 SV, 750 VA
UPC: 803423107802
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 750 VA power rating for moderate industrial loads
- Primary voltage: 380/347V, secondary voltage: 120/240V
- Enclosed design protects against dust, moisture, and contaminants
- Compact and durable construction for control panels and machinery
- US-made transformer for reliable performance in industrial settings
Specifications
Application | HVAC applications, signal ad alarm systems and motor control circuits. |
Connection Type | Screw Terminal (implied by industrial control systems) |
Connection Type | Screw Terminal |
Current Rating | 3.13A (750VA / 240V) |
Enclosure | FS-N1 - Indoor |
Frequency | 60 Hz (implied by US-made and industrial context) |
Frequency | 50/60 Hz |
Frequency Rating | 50/60 HZ |
Height | 5.1 in |
Ip Rating | IP66/IP67 |
Ip Rating | IP66 (implied by 'protection against dust, moisture, and contaminants') |
IP Rating | IP66 |
Length | 5.6 IN |
Material | Durable enclosure (material not explicitly stated) |
Material | Enclosed |
Mounting | Panel |
Mounting Type | Panel/Enclosure Mounting (implied by 'compact design and enclosed construction') |
Mounting Type | Enclosed |
Nema Rating | Type 4X (implied by 'enclosed design' and industrial use) |
Nema Rating | Type 4X |
Power Rating | 750 VA |
Series | FS Series |
Series | FS |
Size | Compact |
Size | Compact (not explicitly stated) |
Special Features | An indoor enclosed control transformer for easy surface mounting. |
Standard | csa, ul, ce |
Temperature Rating | Typical 30 Average/ 40 Maximum Deg C |
Type | Tranformer > Dry Type > Control > Ecnlosed |
Voltage Rating | 380/347 V primary, 120/240 V secondary |
Voltage Rating | 380/347 V (Primary), 120/240 V (Secondary) |
Voltage Rating | 380/347V to 120/240V |
Wattage | 750 VA |
Width | 7.2 in |
Frequently Asked Questions
What type of enclosure does the HPS Fusion transformer have?
The transformer features a rugged TYPE 1 enclosure with split side covers for easy wiring access.
What is the warranty period for HPS Fusion units?
HPS Fusion units come with a 15-year warranty.
Are primary and secondary voltage links/jumpers included?
Yes, all HPS Fusion units are supplied with primary and secondary voltage links/jumpers.
What is the fuse size for the optional fuse holder kit?
The optional fuse holder kit is designed to accept 1/4" x 1 1/4" fuse sizes.
What certifications does the HPS Fusion transformer meet?
The transformer meets NEMA standards, is CSA Certified (file LR 3902), UL Listed (file E50394), CE Marked, and RoHS Compliant.
What is the temperature rise for different VA ratings?
Units from 50-1500 VA have a 95°C temperature rise (Class B), while 2000-5000 VA units have a 130°C rise (Class F).
What are the available primary voltages for Group G transformers?
Group G transformers are available with primary voltages of 380/347.
What is the insulation class for the coils?
The coils have high dielectric strength insulation, with Class B (130°C) for 50-1500 VA and Class F (180°C) for 2000-5000 VA.
What are the dimensions of the wiring knockouts?
There are four wiring knockouts, each 0.88 inches in diameter, and four accessory knockouts, each 0.50 inches in diameter.
What are the operating frequency ranges for this transformer?
The transformers operate at 50/60 Hz, with specific models (FS***ACP and FS***AR) operating at 60 Hz.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.