Authorized Hammond Power Distributor
Hammond Power FS1000MQMJ - General Purpose Enclosed Control Transformer, 240x480 PV, 120x240 SV, 1000 VA
More images

Hammond Power FS1000MQMJ General Purpose Enclosed Control Transformer, 240x480 PV, 120x240 SV, 1000 VA

UPC: 803423107574


Documents & Media
BrochureTechnical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power FS1000MQMJ is a general-purpose enclosed control transformer designed for single-phase, indoor applications requiring stable voltage regulation. This 1000 VA transformer features a primary voltage (PV) of 240x480V and a secondary voltage (SV) of 120x240V, making it suitable for control circuits, automation equipment, and light industrial machinery. Constructed with computer-designed copper wound coils and a single core, the FS1000MQMJ ensures reliable performance in environments where dust or debris may be present. Its enclosed design provides protection for internal components while maintaining convection air cooling for efficient operation. The transformer is designed for linear loads at 50Hz or 60Hz frequencies, offering versatility across standard industrial uses. With a robust construction and common core design, it delivers consistent power delivery for control systems and other light-duty applications. The FS1000MQMJ is part of Hammond Power's HPS Fusion™ line, engineered for dependable operation in demanding operational settings.
  • 1000 VA capacity for single-phase applications
  • Primary voltage: 240x480V, Secondary voltage: 120x240V
  • Enclosed design with convection air cooling
  • Computer-designed copper wound coils and single core construction
  • Suitable for linear loads at 50Hz or 60Hz frequencies

Specifications

Application
HVAC applications, signal ad alarm systems and motor control circuits.
Color
Blue
Connection Type
Screw Terminal
Enclosure
FS-N1 - Indoor
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
5.1 in
Length
5.6 in
Material
Poly
Mounting
Panel
Mounting Type
Enclosed
Series
FS
Series
HPS Fusion™
Special Features
An indoor enclosed control transformer for easy surface mounting.
Standard
csa, ul, ce
Temperature Rating
Typical 30 Average/ 40 Maximum Deg C
Type
Tranformer > Dry Type > Control > Ecnlosed
Voltage Rating
240x480 VAC (Primary), 120x240 VAC (Secondary)
Voltage Rating
240x480 VAC Pri, 120x240 VAC Sec
Wattage
1000 VA
Width
8 in
Package Dimensions (L x W x H)
5.6 IN x 8 IN x 5.1 IN
Package Dimensions (L x W x H)
142.24 mm x 203.2 mm x 129.54 mm
Package Weight (Imperial)
22.800 L
Package Weight (Metric)
10.300 kg
A - 15.0 kV bushing

015J0400AN

A - 15.0 kV bushing
O Plus C - 34.5 kV bushing

034Z3000AW

O Plus C - 34.5 kV bushing

Frequently Asked Questions

What are the typical applications for HPS Fusion enclosed transformers?

These transformers are suitable for single-phase, general-purpose industrial and light-duty loads, including process controls, panel shops, machine automation, control boards, and HVAC panels.

What certifications does the HPS Fusion transformer line hold?

The HPS Fusion line meets NEMA standards, is CSA Certified (file LR 3902), UL Listed (file E50394), CE Marked, and RoHS Compliant.

What type of enclosure does the HPS Fusion transformer use?

The transformers are housed in a rugged TYPE 1 enclosure with split side covers for easy access to the wiring compartment.

Are voltage links or jumpers included with the transformers?

Yes, all HPS Fusion units are supplied with primary and secondary voltage links/jumpers.

What is the warranty period for HPS Fusion units?

The HPS Fusion units come with a 15-year warranty.

What are the available knockout sizes for wiring?

There are four (0.88") [22.35 mm] wiring knockouts and four (0.50") [12.7mm] accessory knockouts provided.

What is the temperature rise for different VA ratings?

Units from 50-1500 VA have a Class B 95°C temperature rise, while 2000-5000 VA units have a Class F 130°C temperature rise.

What are the available primary and secondary voltage options?

Available primary voltages include 600V, 575V, 550V, 480V, 460V, 440V, 380/347V, 277V, 240x480V, 230x460V, 220x440V, 208x416V, 200x400V, and 190x380V.

What is the frequency rating for these transformers?

The transformers operate at 50/60 Hz, with specific models (FS ACP and FS AR) rated for 60 Hz only.

Is there an optional fuse holder available?

Yes, an optional fuse holder kit is available for units up to 250V (25A), designed for 1/4" x 1-1/4" fuse sizes.

How to Install the General Purpose Enclosed Transformer

This guide provides step-by-step instructions for the installation and wiring of the General Purpose Enclosed Transformer.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Remove enclosure covers

    Take off both the primary and secondary connection enclosure covers to access the mounting holes.

  2. Mount the transformer

    Securely attach the transformer to a non-combustible surface using appropriately sized mounting screws. Ensure it is level and stable.

  3. Make electrical connections

    Connect the wires according to the detailed wiring instructions provided with the transformer, ensuring to use the correct wire sizes and connectors.

  4. Ground the transformer

    Ensure a proper ground connection is made in accordance with local electrical codes.

  5. Torque terminal screws

    Tighten all terminal screws to a torque of 12 to 14 inch-lbs to secure the connections.

  6. Verify connections

    Use a multimeter to verify that all electrical connections are secure and functioning correctly before powering on the transformer.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.