Authorized Hammond Power Distributor
Hammond Power FCL2000-5-4 - Current Transformer for Active Harmonic Filter 4" I.D split-core AC line current sensor up to 2000A

Hammond Power FCL2000-5-4 Current Transformer for Active Harmonic Filter 4" I.D split-core AC line current sensor…

UPC: 803423162269


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power FCL2000-5-4 is a 333 mV split-core AC current transformer engineered for active harmonic filter applications. With a substantial 4-inch inner diameter (I.D.) window, it accommodates large conductors, and its nominal current rating extends up to 2000A. The split-core design facilitates straightforward installation on existing electrical systems without the need to disconnect conductors, making it ideal for both retrofitting and new installations. This current transformer features an integrated burden resistor that delivers a precise 0.333 Vac output signal at its rated full-scale current, eliminating the requirement for external shorting blocks. It is directly compatible with popular power meters such as DIRIS A-100/A-200 (333 mV models), WattNode, and DIRIS MCM, simplifying system integration. The FCL2000-5-4 boasts a high accuracy of 0.5% and adheres to stringent safety and performance standards, including UL 2808, CSA-C22.2 No. 61010-1, IEEE/ANSI C57.13, and IEC 61869-1. Its robust construction, coupled with a user-friendly one-handed opening mechanism, ensures ease of installation, even in confined spaces or when wearing safety gloves. This sensor is manufactured in the USA.
  • 2000A nominal current rating for high-capacity systems
  • 4-inch (101.6 mm) inner diameter window for large conductors
  • Split-core design for easy installation on existing wiring
  • 0.333 Vac output signal, compatible with DIRIS, WattNode, and DIRIS MCM
  • 0.5% accuracy for precise measurements
  • UL 2808, CSA-C22.2 No. 61010-1, IEEE/ANSI C57.13, IEC 61869-1 certified

Specifications

Application
Chemical Processing, Data Centers, HVAC, Material Handling, Mining, Oil & Gas, Pulp & Paper, Hospitals, Wastewater
Current Rating
2000 A
Frequency Rating
50-400 Hz
Height
6.5 in
Length
1.5 IN
Mounting Type
Split-core
Series
FCL
Size
4" I.D.
Special Features
I.D split-core AC line current sensor
Standard
cRUL,CE
Type
Accessories > Active Harmonic Filter Accessories > AC line current sensor
Width
6.5 IN
Current Transformer for Active Harmonic Filter 4" I.D split-core AC line current sensor up to 1500A

FCL1500-5-4

Current Transformer for Active Harmonic Filter 4" I.D split-core AC line current sensor up to 1500A
RS422/RS485 repeater 50 Hz 95-240VAC/110-250 VDC

48990120

RS422/RS485 repeater 50 Hz 95-240VAC/110-250 VDC
Active Harmonic Filter 240V 50A 60Hz ETH open;used on 208V

WAHF1D050F-E6B

Active Harmonic Filter 240V 50A 60Hz ETH open;used on 208V
Active Harmonic Filter 240V 50A 60Hz ETH/IP type 1;used on 208V

WAHF1D050A-I6B

Active Harmonic Filter 240V 50A 60Hz ETH/IP type 1;used on 208V
Active Harmonic Filter 480V 200A 60Hz MDB/TCP type 1;used on 400V

WAHF1K200A-T6H

Active Harmonic Filter 480V 200A 60Hz MDB/TCP type 1;used on 400V
Active Harmonic Filter 240V 200A 60Hz ETH open;used on 208V

WAHF1D200F-E6B

Active Harmonic Filter 240V 200A 60Hz ETH open;used on 208V
Active Harmonic Filter 240V 100A 60Hz ETH open;used on 208V

WAHF1D100F-E6B

Active Harmonic Filter 240V 100A 60Hz ETH open;used on 208V
Active Harmonic Filter 240V 200A 60Hz ETH/IP open;used on 208V

WAHF1D200F-I6B

Active Harmonic Filter 240V 200A 60Hz ETH/IP open;used on 208V

Frequently Asked Questions

What is the purpose of the HPS TruWave Active Harmonic Filter?

The AHF is designed to reduce total demand distortion (TDD) and total harmonic distortion (THD(V)) to less than 5%, correct linear displacement, and balance incoming three-phase current.

What is the ambient operating temperature range for the AHF?

The AHF is designed to operate in ambient temperatures ranging from 0° C to 40° C.

How can users view system status and historical data?

Users can view detailed power quality information, operating status, and historical data via the 6-inch color LCD touch screen display on the front panel.

What are the operating voltage and frequency ranges for the AHF?

The AHF operates from 480, 240, or 208 VAC (3-phase, 3-wire plus ground) with a tolerance of +12%, -15%. It functions at 50 or 60 Hz, ±5 Hz.

How does the AHF handle overload conditions?

The AHF uses electronic current limiting to restrict output to 100% of the system's current rating during an overload. It is designed to operate continuously at this limit.

What is the storage temperature range for the AHF?

The AHF should be stored in temperatures between -20° C and 60° C.

How does the AHF monitor incoming line current?

The AHF uses two split-core current transformers on phases A and B to monitor line current. A third CT is used on phase C if line-to-neutral loads are present.

What type of enclosure is the AHF provided in?

The AHF is provided in a NEMA Type 1 gasketed enclosure with air intake filters. Systems rated 50-200 amps are wall-mountable, while 300 amp systems are floor-mountable.

What is the warranty period for the AHF?

The standard factory warranty is at least 18 months from the shipment date or one year from the verified startup date, whichever comes first.

What is the efficiency of the AHF?

The AHF efficiency is no less than 98% at full load, with heat losses not exceeding 2% of the unit's KVAR rating.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.