Authorized Hammond Power Distributor
Hammond Power CRX45D2NC - Reactor, 45.2 Amperes, 0.46 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.
More images

Hammond Power CRX45D2NC Reactor, 45.2 Amperes, 0.46 Millihenries Inductance, 50 Hertz, Copper Windings, Core and…

UPC: 803423150341


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX45D2NC is a robust reactor designed for industrial applications requiring precise current control and harmonic mitigation. Featuring copper windings for optimal conductivity and efficiency, this core and coil reactor operates at 50 Hz with a rated current of 45.2 Amperes and an inductance of 0.46 millihenries. Its construction ensures reliable performance in demanding electrical environments. The HPS Centurion™ R series, to which this reactor belongs, offers an improved product footprint without compromising on performance or reliability. This unit is ideal for power factor correction and harmonic filtering, contributing to a more stable and efficient power system. The CRX45D2NC is built to meet the operational needs of various industrial setups where power quality is paramount. Its specifications make it a dependable choice for engineers and system designers seeking to enhance their electrical infrastructure. The reactor's design focuses on delivering consistent results and longevity in continuous operation.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Durable copper windings
  • Core and coil construction for reliability

Specifications

Package Dimensions (L x W x H)
4.69 IN x 7.12 IN x 6.38 IN
Package Dimensions (L x W x H)
120 mm x 181 mm x 163 mm
Package Weight (Imperial)
19.000 L
Package Weight (Metric)
8.700 kg
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP
REACTOR LRW200D3N1

LRW200D3N1

REACTOR LRW200D3N1
Reactor, 30.5 Amperes, 1.15 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.

CRX30D5PC

Reactor, 30.5 Amperes, 1.15 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.
Reactor, 74.4 Amperes, 0.28 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.

CRX74D4NC

Reactor, 74.4 Amperes, 0.28 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.
Reactors, 23 Amperes, 1.433 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0023PE

Reactors, 23 Amperes, 1.433 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 25 Amperes, 1.769 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0025NE

Reactors, 25 Amperes, 1.769 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 65 Amperes, 0.595 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0065NE

Reactors, 65 Amperes, 0.595 Millihenries Inductance, 50 Hertz, Enclosed.

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

The reactors support system voltage ratings of 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz. For 50 Hz, they support 380 V, 525 V, and 690 V.

What are the available impedance ratings for these reactors?

The available impedance ratings are 1.5%, 3%, and 5%.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

What is the system frequency for which impedance levels are specified?

Impedance levels are specified for 60 Hz operation.

How are the reactors constructed to minimize audible noise?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending motor life, reducing audible noise, and minimizing harmonic distortion.

What cooling method is used for the HPS Centurion R reactors?

The cooling method is natural convection.

What are the compliance and approvals for HPS Centurion R reactors?

They are compliant with UL, CSA, CE, IEC, and NEMA standards, including UL 508, CSA C9, and CE Mark (IEC 61558-2-20:2000).

What type of terminal connections are provided on rated currents below 65 Amps?

Finger-proof terminal blocks are provided on rated currents of approximately below 65 Amps.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.