Authorized Hammond Power Distributor
Hammond Power CRX06D6BC - 600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt

Hammond Power CRX06D6BC 600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT…

UPC: 803423119102


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX06D6BC is a 600V Class Iron Core Reactor engineered for industrial power systems that demand precise current control and stable voltage regulation. Designed with a core and coil assembly, it delivers a rated current of 6.6 Amps and an inductance of 1.48 Henries, ensuring consistent performance under operational loads. Operating efficiently at a 60Hz frequency, the reactor maintains a 3% impedance at 208 Volts, making it a reliable choice for applications requiring power factor correction, harmonic filtering, and motor control. Its durable iron core construction provides high thermal stability and low losses, enhancing overall system efficiency. The reactor is particularly well-suited for demanding environments found in industrial machinery, HVAC systems, and renewable energy installations, where reliability and performance are critical. Built to meet stringent UL and CSA safety standards, the CRX06D6BC features a compact and robust design that supports long-term operational integrity. Manufactured in the United States, this reactor offers OEMs and system integrators a cost-effective, high-quality electrical component that meets the rigorous demands of modern power distribution and control systems.
  • 600V Class Iron Core Reactor for industrial power systems
  • Rated 6.6A current, 1.48H inductance, 60Hz frequency
  • 3% impedance at 208V for power factor correction and harmonic filtering
  • Durable iron core and coil assembly for reliable performance
  • UL and CSA certified, US-made for OEM and system integrator applications

Specifications

Amperage Rating
6.6 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
6.6 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
5.13 in
Impedance
3% at 208 V
Impedance
0.03
Inductance
1.48 H
Input Voltage
208 Volt
Length
2.29 in
Material
Iron Core
Material
Iron
Material
Iron Core and Coil
Mounting
Floor or Panel Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
4.13 in
Package Dimensions (L x W x H)
5.13 IN x 4.13 IN x 2.29 IN
Package Dimensions (L x W x H)
13.0302 cm x 10.4902 cm x 5.8166 cm
Package Weight (Imperial)
3.000 L
Package Weight (Metric)
1.361 kg
600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX06D6AC

600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt
KDR, 600V, 5 HP / 5 1/2 HP, 6.10 Motor Amps

KDRAA58L2E01

KDR, 600V, 5 HP / 5 1/2 HP, 6.10 Motor Amps
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Core and Coil, 2.1 Amps, 10.61 Inductance, 60 Hz

CRX02D1AC

600V Class Iron Core Reactor, Core and Coil, 2.1 Amps, 10.61 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 7.5 Amps, 2.33 Inductance, 60 Hz, 5 PCT Impedance at 208 Volt

CRX07D5DC

600V Class Iron Core Reactor, Core and Coil, 7.5 Amps, 2.33 Inductance, 60 Hz, 5 PCT Impedance at 208 Volt
600V Class Iron Core Reactor, Enclosed, 289 Amps, 0.10 Inductance, 60 Hz

CRX0289AE

600V Class Iron Core Reactor, Enclosed, 289 Amps, 0.10 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 6.1 Amps, 7.78 Inductance, 60 Hz

CRX06D1BC

600V Class Iron Core Reactor, Core and Coil, 6.1 Amps, 7.78 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 2.33 Inductance, 60 Hz

CRX06D6CC

600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 2.33 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V (de-rated) at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The impedance ratings available for the HPS Centurion R reactors are 1.5%, 3%, and 5%.

What standards are HPS Centurion R reactors certified to?

HPS Centurion R reactors are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

What is used to impregnate the reactors to minimize audible noise?

Every reactor is vacuum pressure impregnated with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What is the cooling method for the HPS Centurion R reactors?

The cooling method for these reactors is natural convection.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

How do HPS reactors protect motors and AC drives?

HPS reactors protect motors and AC drives by attenuating voltage and current transients, minimizing power system harmonics, and reducing harmonic current levels.

What benefits do HPS reactors offer when used with AC drives?

When used with AC drives, HPS reactors reduce motor operating temperature and audible noise by moderating line transients, enhancing system performance and motor life.

What type of terminals are provided for different current ratings?

Finger-proof terminal blocks are provided for currents below approximately 65 Amps, while terminal pads are supplied for approximately 65 Amps and above.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.