Authorized Hammond Power Distributor
Hammond Power CRX0600CC - Reactor, Three Phase, 600 Horsepower, 3% impedance, 600 amperes, Copper Windings, 60 Hertz, Enclosed.
More images

Hammond Power CRX0600CC Reactor, Three Phase, 600 Horsepower, 3% impedance, 600 amperes, Copper Windings, 60…

UPC: 803423139094


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power Solutions (HPS) Centurion™ R CRX0600CC is a robust three-phase reactor designed for demanding industrial applications. Engineered with 600 horsepower (HP) rating and a 600 ampere (A) current capacity, this reactor features a precise 3% impedance, crucial for optimizing motor performance and protecting sensitive equipment. The CRX0600CC utilizes high-quality copper windings, ensuring superior conductivity and thermal management for reliable, long-term operation. Operating at a standard 60 Hertz (Hz) system frequency, this unit is built to withstand rigorous conditions. The "R" in the model designation signifies a Type 3R enclosure, providing protection against falling rain and sleet, making it suitable for outdoor or exposed installations. This enclosed design enhances safety and longevity. HPS reactors, like the Centurion™ R series, are instrumental in smoothing current waveforms, which directly contributes to increased operational efficiency and can lead to reduced energy consumption and lower overall operating costs. The inductance tolerance is specified at +15/-10%, and the insulation system offers a 70ºC rise over a 50°C ambient for 130ºC Temperature Class on units up to 40A, and 115ºC rise for larger units with 180ºC and 220ºC Temperature Classes. This reactor complies with UL 508, CSA C9, CSA C22.2 No. 47, and carries the CE Mark (IEC 61558-2-20:2000). It is UL Listed (file No. E61431) and CSA Certified (file No. LR3902). The CRX0600CC is manufactured in the USA, ensuring adherence to stringent quality standards. Its compact footprint, as highlighted by the Centurion™ R series, offers an advantage in installations where space is a consideration, without compromising on performance or reliability. This reactor is an essential component for motor control centers, variable frequency drives (VFDs), and other applications requiring precise current control and harmonic mitigation.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Operates at 60 Hertz (Hz) system frequency
  • Type 3R enclosed for outdoor and exposed installations

Specifications

Current Rating
600 A
Frequency
60 Hz
Material
Copper
Mounting Type
Enclosed
Series
HPS Centurion™ R
Package Dimensions (L x W x H)
12.13 IN x 13.75 IN x 14.5 IN
Package Dimensions (L x W x H)
309 mm x 350 mm x 369 mm
Package Weight (Imperial)
210.000 L
Package Weight (Metric)
96.000 kg
Reactor, Three Phase, 600 Horsepower, 5% Impedance, 600 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0600EE

Reactor, Three Phase, 600 Horsepower, 5% Impedance, 600 Amperes, Copper Windings, 60 Hertz, Enclosed.
REACTOR LRW250G3N1

LRW250G3N1

REACTOR LRW250G3N1
KDR, 480V, 600A, 450HP

KDRL3PC5

KDR, 480V, 600A, 450HP
Reactor, 37.8 Amperes, 0.942 Millihenries Inductance, 50 Hertz, Enclosed.

CRX37D8PE

Reactor, 37.8 Amperes, 0.942 Millihenries Inductance, 50 Hertz, Enclosed.
Reactor, Three Phase, 900 Horsepower, 3% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX0900CE

Reactor, Three Phase, 900 Horsepower, 3% Impedance, 900 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactors, 4.8 Amperes, 7.784 Millihenries Inductance, 50 Hertz, Enclosed.

CRX04D8PE

Reactors, 4.8 Amperes, 7.784 Millihenries Inductance, 50 Hertz, Enclosed.
Reactor, 11.8 Amperes, 1.66 Millihenries Inductance, 50 Hertz, Enclosed.

CRX11D8NE

Reactor, 11.8 Amperes, 1.66 Millihenries Inductance, 50 Hertz, Enclosed.
Reactor, 11.8 Amperes, 2.73 Millihenries Inductance, 50 Hertz, Enclosed.

CRX11D8PE

Reactor, 11.8 Amperes, 2.73 Millihenries Inductance, 50 Hertz, Enclosed.

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

Supported system voltages include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V (de-rated) at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The available impedance ratings are 1.5%, 3%, and 5%.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending motor life, reducing audible noise, and minimizing harmonic distortion.

What standards are HPS Centurion R reactors compliant with?

They are compliant with UL, CSA, CE, IEC, and NEMA standards.

What is the warranty period for HPS Centurion R reactors?

HPS Centurion R reactors come with a 10-year limited warranty.

How are the reactors protected against audible noise?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What type of enclosure is standard for HPS Centurion R reactors?

Type 1 enclosure is standard, with Type 3R available upon consultation.

What is the inductance tolerance for these reactors?

The inductance tolerance is +15/-10%.

What cooling method is used for the HPS Centurion R reactors?

The cooling method is natural convection.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.