Authorized Hammond Power Distributor
Hammond Power CRX0590BC - 600V Class Iron Core Reactor, Core and Coil, 590 Amps, 0.06 Inductance, 60 Hz

Hammond Power CRX0590BC 600V Class Iron Core Reactor, Core and Coil, 590 Amps, 0.06 Inductance, 60 Hz

UPC: 803423119065


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0590BC is a 600V Class iron core reactor designed for industrial power systems requiring precise current control. Rated at 590A continuous current with 0.06H inductance at 60Hz, this core and coil unit provides stable reactance for harmonic filtering, motor control, and power factor correction applications. The iron core construction delivers high thermal stability and efficient energy transfer, reducing system losses while extending equipment lifespan. With an open enclosure design (Dim. Figure #4), the CRX0590BC features mounting dimensions of 9.00" width x 13.75" depth x 14.50" height, mounting depth of 9.92" (252mm), and mounting slot of 0.44 x 1.0" (11 x 26mm). Weighing 230 lbs (104 kg), this reactor is optimized for medium-voltage systems up to 600V, supporting commercial and industrial facilities where minimal voltage distortion and precise current regulation are critical. Manufactured in the USA to UNSPSC 39121015 specifications, the CRX0590BC meets strict quality standards for reliability in harsh operating environments.
  • 600V Class iron core reactor with 590A continuous current rating
  • 0.06H inductance at 60Hz for stable reactance and current control
  • Open enclosure design (Dim. Figure #4) with compact footprint
  • Mounting dimensions: 9.00" W x 13.75" D x 14.50" H, 230 lbs weight
  • Ideal for harmonic filtering, motor control, and power factor correction

Specifications

Amperage Rating
590 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
590 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
14.5 in
Impedance
0.05
Inductance
0.06 H
Input Voltage
480 Volt
Length
13.38 in
Material
Iron Core
Mounting
Floor Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 VAC
Voltage Rating
600 V
Width
13.75 in
Package Dimensions (L x W x H)
14.5 IN x 13.75 IN x 13.38 IN
Package Dimensions (L x W x H)
36.83 cm x 34.925 cm x 33.9852 cm
Package Weight (Imperial)
220.000 L
Package Weight (Metric)
99.792 kg
600V Class Iron Core Reactor, Core and Coil, 515 Amps, 0.08 Inductance, 60 Hz

CRX0515BC

600V Class Iron Core Reactor, Core and Coil, 515 Amps, 0.08 Inductance, 60 Hz
TCI, S-G, Std, 3-Ph

KLR600DCB5

TCI, S-G, Std, 3-Ph
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX06D6AC

600V Class Iron Core Reactor, Core and Coil, 6.6 Amps, 1.48 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt
600V Class Iron Core Reactor, Core and Coil, 528 Amps, 0.04 Inductance, 60 Hz

CRX0528DC

600V Class Iron Core Reactor, Core and Coil, 528 Amps, 0.04 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 273 Amps, 0.04 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX0273AE

600V Class Iron Core Reactor, Enclosed, 273 Amps, 0.04 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt
600V Class Iron Core Reactor, Core and Coil, 3.9 Amps, 7.06 Inductance, 60 Hz

CRX03D9AC

600V Class Iron Core Reactor, Core and Coil, 3.9 Amps, 7.06 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 273 Amps, 0.04 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX0273AC

600V Class Iron Core Reactor, Core and Coil, 273 Amps, 0.04 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

The HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What impedance ratings are available for the reactors?

The available impedance ratings for the reactors are 1.5%, 3%, and 5%.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed, and CSA Certified.

What is the cooling method for these reactors?

The cooling method employed is natural convection.

What is the inductance tolerance for the reactors?

The inductance tolerance is +15/-10%.

What is the dielectric strength to ground rating?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending motor life, reducing motor noise and temperature, and minimizing harmonic distortion.

How are the reactors protected against audible noise?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.