Hammond Power CRX0528BC 600V Class Iron Core Reactor, Core and Coil, 528 Amps, 0.02 Inductance, 60 Hz, 3 PCT…
UPC: 803423119027
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated 528 Amps, 0.02 Henries (20 mH) inductance at 60 Hz
- 3% impedance at 208V; compatible with 208V, 240V, 480V, and 600V systems
- Natural convection cooling; dielectric strength 4000V for 1 minute
- UL 508, CSA C9, CE Mark, and IEC 61558-2-20 certified
- Open-style or Type 1/Type 3R enclosures; 10-year limited warranty
Specifications
Amperage Rating | 528 Amp |
Application | Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive |
Enclosure | Core and Coil |
Frequency Rating | 50/60 HZ |
Height | 12.5 in |
Impedance | 0.03 |
Input Voltage | 208 Volt |
Length | 9.38 in |
Mounting | Floor Mount |
Noise Level | Between 58dBA to 75 dBA |
Phase | 3 |
Special Features | Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping. |
Standard | csa, ul, ce |
Type | Reactors > Air Core > Centurion R series |
Width | 13.75 in |
Package Dimensions (L x W x H) | 12.5 IN x 13.75 IN x 9.38 IN |
Package Dimensions (L x W x H) | 31.75 cm x 34.925 cm x 23.8252 cm |
Package Weight (Imperial) | 74.000 L |
Package Weight (Metric) | 33.566 kg |
Frequently Asked Questions
What is the power rating range for HPS Centurion R reactors?
HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).
What voltage ratings are available for HPS Centurion R reactors?
Available system voltage ratings include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V.
What impedance ratings are offered for these reactors?
The impedance ratings available for the reactors are 1.5%, 3%, and 5%.
What standards are HPS Centurion R reactors certified to?
They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.
What is the cooling method for these reactors?
The cooling method employed is natural convection.
What is the warranty period for HPS Centurion R reactors?
The HPS Centurion R reactors come with a 10-year limited warranty.
What is the inductance tolerance for these reactors?
The inductance tolerance is specified as +15/-10%.
How do these reactors protect motors and AC drives?
They protect motors and AC drives by attenuating voltage and current transients and minimizing harmonic current levels.
What are the benefits of using HPS Centurion R reactors?
Benefits include mitigating nuisance tripping, extending component life, reducing motor noise and temperature, and minimizing harmonic distortion.
What is the insulation system for units larger than 40A?
For units larger than 40A, there is a 115ºC rise over average 50°C ambient for 180ºC and 220ºC Temperature Classes.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.