Authorized Hammond Power Distributor
Hammond Power CRX02D4DE - 600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 7.06 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

Hammond Power CRX02D4DE 600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 7.06 Inductance, 60 Hz, 3 PCT…

UPC: 803423120870


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX02D4DE is a 600V Class iron core reactor designed for precise impedance control in industrial power systems. This enclosed unit delivers a rated current of 2.4 Amps with an inductance of 7.06 millihenries (mH) at 60 Hz, providing a 3% impedance rating at 240 Volts. Engineered for non-linear load applications, it meets the requirements of UL 1561, CSA C22.2 No. 47, and IEEE 519 standards for harmonic spectrum management in switching power supplies and motor control circuits. Each unit undergoes rigorous production testing, including DC resistance and high-potential (Hi-Pot) insulation tests, ensuring reliable performance in demanding environments. The CRX02D4DE is suitable for applications such as harmonic filtering, motor control circuits, and power factor correction, where controlled impedance is critical to system stability and efficiency. With a 1.2kV class rating, this reactor is built for long-term operation in industrial settings, providing consistent impedance to mitigate voltage spikes and current harmonics. Its robust iron core design ensures minimal losses and stable inductance across operating conditions. The enclosed construction enhances durability and safety, making it ideal for integration into power distribution systems, variable frequency drives (VFDs), and other industrial equipment requiring precise electrical conditioning.
  • 600V Class iron core reactor with 2.4A rated current
  • Inductance of 7.06mH at 60Hz with 3% impedance at 240V
  • Enclosed design for durability and safety in industrial environments
  • Suitable for harmonic filtering, motor control, and power factor correction
  • 3% Impedance at 240 Volt

Specifications

Amperage Rating
2.4 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
2.4 A
Enclosure
N1-N1/IP20 - Indoor
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
8.13 in
Impedance
3% Z @ 240V
Impedance
0.05
Inductance
7.06 mH
Input Voltage
208 Volt
Length
10 IN
Material
Iron Core
Material
Iron
Mounting
Floor or Panel Mount
Mounting Type
Enclosed
Nema Rating
Enclosed
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Voltage Rating
240 V
Width
10 IN
Package Dimensions (L x W x H)
8.13 IN x 10 IN x 10 IN
Package Dimensions (L x W x H)
20.6502 cm x 25.4 cm x 25.4 cm
Package Weight (Imperial)
8.000 L
Package Weight (Metric)
3.629 kg
600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 4.67 Inductance, 60 Hz

CRX02D4AE

600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 4.67 Inductance, 60 Hz
KDR, 480V, 1 HP, 2.10 Motor Amps

KDRMA5L1E3R1

KDR, 480V, 1 HP, 2.10 Motor Amps
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Enclosed, 192 Amps, 0.15 Inductance, 60 Hz

CRX0192AE

600V Class Iron Core Reactor, Enclosed, 192 Amps, 0.15 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 88 Amps, 0.24 Inductance, 60 Hz

CRX0088DE

600V Class Iron Core Reactor, Enclosed, 88 Amps, 0.24 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 7.06 Inductance, 60 Hz, 5 PCT Impedance at 240 Volt

CRX02D4CE

600V Class Iron Core Reactor, Enclosed, 2.4 Amps, 7.06 Inductance, 60 Hz, 5 PCT Impedance at 240 Volt
600V Class Iron Core Reactor, Enclosed, 3.5 Amps, 2.80 Inductance, 60 Hz

CRX03D5AE

600V Class Iron Core Reactor, Enclosed, 3.5 Amps, 2.80 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 2.6 Amps, 10.61 Inductance, 60 Hz

CRX02D6AE

600V Class Iron Core Reactor, Enclosed, 2.6 Amps, 10.61 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

Supported system voltages include 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What impedance ratings are available for HPS Centurion R reactors?

HPS Centurion R reactors are available with impedance ratings of 1.5%, 3%, and 5%.

What standards are HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed, and CSA Certified standards.

What is the cooling method for HPS Centurion R reactors?

The cooling method for these reactors is natural convection.

What is the inductance tolerance for HPS Centurion R reactors?

The inductance tolerance for these reactors is +15/-10%.

What is the warranty period for HPS Centurion R reactors?

HPS Centurion R reactors come with a 10-year limited warranty.

What are the system frequency ratings for these reactors?

The system frequency rating is 50/60 Hertz.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

How do HPS reactors protect AC drive systems?

HPS reactors protect motors and AC drives by attenuating voltage and current transients, minimizing power system harmonics, and reducing nuisance tripping.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.