Authorized Hammond Power Distributor
Hammond Power CRX02D1NE - Reactors, 2.1 Amperes, 10.61 Millihenries Inductance, 50 Hertz, Enclosed.
More images

Hammond Power CRX02D1NE Reactors, 2.1 Amperes, 10.61 Millihenries Inductance, 50 Hertz, Enclosed.

UPC: 803423150075


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX02D1NE Centurion™ R reactor is engineered for precise current control in 50 Hz industrial applications. This enclosed unit features a 2.1 Ampere current rating and 10.61 millihenries of inductance, making it ideal for harmonic filtering and power factor correction. Its robust enclosure protects internal components from dust and contaminants, ensuring reliable operation in demanding environments. The CRX02D1NE is specifically designed for use with variable frequency drives (VFDs), motor controls, and renewable energy systems operating on 50 Hz power grids. The Centurion™ R series benefits from Hammond Power's extensive experience in magnetic component design, delivering consistent performance and thermal stability. With its compact, enclosed chassis, this reactor simplifies installation within control panels and industrial enclosures, offering a space-saving solution compared to open-frame alternatives. It is well-suited for both new installations and retrofits where reliable inductive reactance is critical for continuous operation. The SKU CRX02D1NE signifies a dependable component for optimizing power quality and system efficiency.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Enclosed chassis for dust and contaminant protection
  • Ideal for VFDs, motor controls, and renewable energy systems

Specifications

Current Rating
2.1 A
Frequency
50 Hz
Series
Centurion™ R
Series
Centurion™ R series
Package Dimensions (L x W x H)
8 IN x 10 IN x 8.13 IN
Package Dimensions (L x W x H)
203 mm x 254 mm x 206 mm
Package Weight (Imperial)
8.000 L
Package Weight (Metric)
3.700 kg
KDR, 480V, 1 HP, 2.10 Motor Amps

KDRMA5L1

KDR, 480V, 1 HP, 2.10 Motor Amps
Reactors, 2.1 Amperes, 17.83 Millihenries Inductance, 50 Hertz, Enclosed.

CRX02D1PE

Reactors, 2.1 Amperes, 17.83 Millihenries Inductance, 50 Hertz, Enclosed.
REACTOR LRW130G3N1

LRW130G3N1

REACTOR LRW130G3N1
Reactor, Three Phase, 1000 Horsepower, 3% Impedance, 1000 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX1000CE

Reactor, Three Phase, 1000 Horsepower, 3% Impedance, 1000 Amperes, Copper Windings, 60 Hertz, Enclosed.
Reactor, Three Phase, 800 Horsepower, 5% Impedance, 1000 Amperes, Copper Windings, 60 Hertz, Enclosed.

CRX1000DE

Reactor, Three Phase, 800 Horsepower, 5% Impedance, 1000 Amperes, Copper Windings, 60 Hertz, Enclosed.
KDR, 480V, 2 HP, 3.40 Motor Amps

KDRAA1H2DR

KDR, 480V, 2 HP, 3.40 Motor Amps
KDR, 208V, 3 HP, 10.6 Motor Amps

KDRAA28H2E01

KDR, 208V, 3 HP, 10.6 Motor Amps
KDR, 480V, 2 HP, 3.40 Motor Amps

KDRAA1H2E3R1

KDR, 480V, 2 HP, 3.40 Motor Amps

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

Supported system voltages include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What impedance ratings are available for HPS Centurion R reactors?

The impedance ratings available are 1.5%, 3%, and 5%.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending component life, reducing motor noise and temperature, and minimizing harmonic distortion.

What standards are HPS Centurion R reactors compliant with?

They are compliant with UL, CSA, CE, IEC, and NEMA standards.

What is the cooling method for HPS Centurion R reactors?

The cooling method is natural convection.

What is the warranty period for HPS Centurion R reactors?

The product comes with a 10-year limited warranty.

What is the inductance tolerance for these reactors?

The inductance tolerance is +15/-10%.

How are HPS Centurion R reactors constructed for reliability?

Reactors are vacuum pressure impregnated (VPI) with VT Polyester Resin to minimize audible noise and may use bobbins for mechanical strength.

What type of enclosure is standard for HPS Centurion R reactors?

The standard enclosure is Type 1, with Type 3R available upon consultation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.