Hammond Power CRX0211BE - 600V Class Iron Core Reactor, Enclosed, 211 Amps, 0.05 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt

Hammond Power CRX0211BE 600V Class Iron Core Reactor, Enclosed, 211 Amps, 0.05 Inductance, 60 Hz, 3 PCT…

UPC: 803423120795


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0211BE is an enclosed iron core reactor designed for precise current control and voltage regulation in industrial power systems. This reactor is rated for 600V class operation and handles up to 211 Amps. It features a nominal inductance of 0.05 Henry (50 mH) and operates at a standard 60 Hz frequency. A key specification is its 3% impedance rating at 208 Volt, crucial for managing power flow and harmonic distortion. The CRX0211BE is housed in a Type 1 N1 enclosure, providing protection against environmental factors and ensuring reliable operation in various industrial settings. Manufactured in the USA, this reactor meets stringent quality standards, including UL 508, CSA C22.2 No. 47, and CE Mark (IEC 61558-2-20:2000). It is also UL Listed (file No. E61431) and CSA Certified (file No. LR3902). Applications include power distribution, motor control circuits, and harmonic filtering. The dimensions for this unit are 10.00 inches in width, 8.00 inches in depth, and 8.13 inches in height, with mounting dimensions of 7.00 inches width and 6.50 inches depth. Its weight is 9.50 lbs (4.30 kg). Hammond Power's commitment to quality and performance is evident in the CRX0211BE, offering enhanced system stability and operational efficiency.
  • 600V Class Iron Core Reactor
  • 211 Amps continuous current rating
  • 0.05 Henry (50 mH) inductance
  • 3% Impedance at 208 Volt
  • Type 1 N1 Enclosure, Made in USA

Specifications

Amperage Rating
211 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Enclosure
N2-N1/IP20 - Indoor
Frequency Rating
50/60 HZ
Height
12.13 in
Impedance
0.03
Input Voltage
208 Volt
Length
14 IN
Mounting
Floor Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Width
14 IN
Package Dimensions (L x W x H)
12.13 IN x 14 IN x 14 IN
Package Dimensions (L x W x H)
30.8102 cm x 35.56 cm x 35.56 cm
Package Weight (Imperial)
34.000 L
Package Weight (Metric)
15.422 kg
600V Class Iron Core Reactor, Enclosed, 211 Amps, 0.05 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX0211AE

600V Class Iron Core Reactor, Enclosed, 211 Amps, 0.05 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt
KLR, 575V, 200A, 200HP

KLR200DCB

KLR, 575V, 200A, 200HP
REACTOR LRW320G3N1

LRW320G3N1

REACTOR LRW320G3N1
600V Class Iron Core Reactor, Enclosed, 16.7 Amps, 1.06 Inductance, 60 Hz

CRX16D7CE

600V Class Iron Core Reactor, Enclosed, 16.7 Amps, 1.06 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 88 Amps, 0.19 Inductance, 60 Hz

CRX0088CE

600V Class Iron Core Reactor, Enclosed, 88 Amps, 0.19 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 16.7 Amps, 0.59 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt

CRX16D7AE

600V Class Iron Core Reactor, Enclosed, 16.7 Amps, 0.59 Inductance, 60 Hz, 3 PCT Impedance at 240 Volt
600V Class Iron Core Reactor, Enclosed, 1.6 Amps, 14.91 Inductance, 60 Hz

CRX01D6AE

600V Class Iron Core Reactor, Enclosed, 1.6 Amps, 14.91 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 2.1 Amps, 17.83 Inductance, 60 Hz

CRX02D1BE

600V Class Iron Core Reactor, Enclosed, 2.1 Amps, 17.83 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

The HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What are the available impedance ratings for the reactors?

The impedance ratings available for these reactors are 1.5%, 3%, and 5%.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

How do these reactors protect motors and AC drives?

They protect motors and AC drives by attenuating voltage and current transients, minimizing power system harmonics, and reducing audible noise.

What is the purpose of vacuum pressure impregnation (VPI) with VT Polyester Resin?

VPI with VT Polyester Resin is used to minimize audible noise from the reactor.

What type of terminal connections are provided on the reactors?

Finger-proof terminal blocks are provided for currents below approximately 65 Amps, and terminal pads are supplied for 65 Amps and above.

What is the warranty period for the HPS Centurion R reactors?

The reactors come with a 10-year limited warranty.

What are the enclosure options for the reactors?

Standard enclosures are Type 1, with Type 3R available upon consultation. Enclosure Kits are also available separately.

What is the inductance tolerance for these reactors?

The inductance tolerance for the reactors is +15/-10%.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.