Hammond Power CRX0192AC - 600V Class Iron Core Reactor, Core and Coil, 192 Amps, 0.15 Inductance, 60 Hz

Hammond Power CRX0192AC 600V Class Iron Core Reactor, Core and Coil, 192 Amps, 0.15 Inductance, 60 Hz

UPC: 803423118280


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0192AC is a 600V Class Iron Core Reactor designed for industrial applications. This reactor features a core and coil construction, built to handle 192 Amps continuously at a frequency of 60 Hz. Its inductance rating is 0.15 Henries. The CRX0192AC is suitable for use in systems requiring harmonic filtering, power factor correction, and motor control, particularly with variable frequency drives (VFDs) and adjustable speed drives (ASDs). The reactor is engineered to manage non-linear loads as defined by IEEE 519 and IEEE C57.110. Production tests include DC resistance and Hi-pot testing to ensure reliable operation. This iron core reactor provides essential inductive properties for stable and efficient electrical system performance. SKU: CRX0192AC.
  • 600V Class Iron Core Reactor
  • 192 Amp Current Rating
  • 0.15 Henries Inductance
  • 60 Hz Frequency
  • Core and Coil Construction

Specifications

Amperage Rating
192 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
192 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
7 in
Impedance
0.03
Input Voltage
600 Volt
Length
8.25 in
Material
Iron Core
Mounting
Floor mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
9.25 in
Package Dimensions (L x W x H)
7 IN x 9.25 IN x 8.25 IN
Package Dimensions (L x W x H)
17.78 cm x 23.495 cm x 20.955 cm
Package Weight (Imperial)
53.000 L
Package Weight (Metric)
24.041 kg
600V Class Iron Core Reactor, Core and Coil, 200 Amps, 0.11 Inductance, 60 Hz

CRX0200CC

600V Class Iron Core Reactor, Core and Coil, 200 Amps, 0.11 Inductance, 60 Hz
KDR, 575V, 192A, 200HP

KDRI42LC4

KDR, 575V, 192A, 200HP
REACTOR LRW080G3N1

LRW080G3N1

REACTOR LRW080G3N1
600V Class Iron Core Reactor, Core and Coil, 1.6 Amps, 23.55 Inductance, 60 Hz

CRX01D6BC

600V Class Iron Core Reactor, Core and Coil, 1.6 Amps, 23.55 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.14 Inductance, 60 Hz

CRX0114CC

600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.14 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 192 Amps, 0.25 Inductance, 60 Hz

CRX0192BC

600V Class Iron Core Reactor, Core and Coil, 192 Amps, 0.25 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.19 Inductance, 60 Hz

CRX0114DC

600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.19 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 1.6 Amps, 14.91 Inductance, 60 Hz

CRX01D6AC

600V Class Iron Core Reactor, Core and Coil, 1.6 Amps, 14.91 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

The HPS Centurion R reactors are available in power ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

Supported system voltages include 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What are the available impedance ratings for the reactors?

The reactors are available with impedance ratings of 1.5%, 3%, and 5%.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed, CSA Certified, and IEC 61558-2-20.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending motor life, reducing noise and operating temperature, and minimizing harmonic distortion.

What is the warranty period for the HPS Centurion R reactors?

The product comes with a 10 year limited warranty.

What is the system frequency for which impedance levels are specified?

The impedance levels are for 60 Hz operation.

How does the VPI impregnation benefit the reactor?

The reactors are vacuum pressure impregnated (VPI) with VT Polyester Resin to minimize audible noise.

What type of terminals are used for different current ratings?

Finger-proof terminal blocks are used for currents below approximately 65 Amps, while terminal pads are supplied for 65 Amps and above.

What is the cooling method for the HPS Centurion R reactors?

The cooling method is natural convection.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.