Authorized Hammond Power Distributor
Hammond Power CRX0075AC - 600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.12 Inductance, 60 Hz

Hammond Power CRX0075AC 600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.12 Inductance, 60 Hz

UPC: 803423117900


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0075AC is a 600V Class iron core reactor designed for three-phase power systems requiring stable current control and harmonic mitigation. Rated for 75 Amps continuous operation with 0.12 Henries inductance at 60 Hz, this reactor is optimized for non-linear load applications such as motor drives, power distribution systems, and renewable energy installations. The iron core construction minimizes energy losses while maintaining efficiency under fluctuating load conditions. This unit is specified per UL 508, CSA C22.2 No. Its robust design supports long-term durability in high-voltage industrial settings.
  • 600V Class iron core reactor for three-phase power systems
  • 75 Amps continuous current rating with 0.12 Henries inductance at 60 Hz
  • Designed for non-linear load applications including motor drives and renewable energy systems
  • Optimized for harmonic mitigation per IEEE 519 and IEEE C57.110 guidelines
  • Manufactured in the US by Hammond Power

Specifications

Amperage Rating
75 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
75 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
5.63 IN
Impedance
0.03
Inductance
0.12 H
Input Voltage
208 Volt
Length
5.88 in
Material
Iron Core and Coil
Material
Iron Core
Mounting
Floor or Panel Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
7.25 IN
Package Dimensions (L x W x H)
5.63 IN x 7.25 IN x 5.88 IN
Package Dimensions (L x W x H)
14.3002 cm x 18.415 cm x 14.9352 cm
Package Weight (Imperial)
17.000 L
Package Weight (Metric)
7.711 kg
600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.19 Inductance, 60 Hz

CRX0075BC

600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.19 Inductance, 60 Hz
KDR, 575V, 80A, 60HP

KDRF31PE3R

KDR, 575V, 80A, 60HP
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.29 Inductance, 60 Hz

CRX0075DC

600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.29 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 46 Amps, 0.21 Inductance, 60 Hz, 1.5 PCT Impedance at 480 Volt

CRX0046AC

600V Class Iron Core Reactor, Core and Coil, 46 Amps, 0.21 Inductance, 60 Hz, 1.5 PCT Impedance at 480 Volt
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 4.28 Inductance, 60 Hz

CRX0011DC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 4.28 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.22 Inductance, 60 Hz

CRX0075CC

600V Class Iron Core Reactor, Core and Coil, 75 Amps, 0.22 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 1.8 Amps, 27.20 Inductance, 60 Hz

CRX01D8BC

600V Class Iron Core Reactor, Core and Coil, 1.8 Amps, 27.20 Inductance, 60 Hz

Frequently Asked Questions

What are the available impedance ratings for the reactors?

The available impedance ratings for the HPS Centurion R reactors are 1.5%, 3%, and 5%.

What is the cooling method for the HPS Centurion R reactors?

The cooling method employed is natural convection.

What type of terminal blocks are provided on the reactors?

Finger-proof terminal blocks are provided on units below approximately 65 Amps, and terminal pads are supplied on units 65 Amps and above.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

How do HPS reactors protect motors and AC drives?

HPS reactors attenuate voltage and current transients, minimize harmonic current levels, reduce motor operating temperature, and moderate line transients.

What is the inductance tolerance for these reactors?

The inductance tolerance for the HPS Centurion R reactors is +15/-10%.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.