Authorized Hammond Power Distributor
Hammond Power CRX0065AC - 600V Class Iron Core Reactor, Core and Coil, 65 Amps, 0.34 Inductance, 60 Hz

Hammond Power CRX0065AC 600V Class Iron Core Reactor, Core and Coil, 65 Amps, 0.34 Inductance, 60 Hz

UPC: 803423117887


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0065AC is a robust 600V Class Iron Core Reactor, meticulously engineered for demanding industrial power applications. This reactor is built with a core and coil construction utilizing high-quality iron, ensuring reliable and consistent performance within power systems. It boasts a substantial 65 Amp rating, making it capable of handling significant current loads. The CRX0065AC provides a precise inductance value of 0.34 Henry, a critical parameter for its intended functions. Operating efficiently at a standard 60 Hz frequency, this reactor is designed to meet the operational requirements of a wide range of industrial environments. Its primary functions include effective current limiting, which helps to protect downstream equipment from sudden surges, and harmonic filtering, contributing to improved power quality by reducing unwanted electrical noise. These capabilities make the CRX0065AC an essential component for safeguarding sensitive electronic equipment and ensuring the stable operation of industrial machinery. Its versatility extends to various applications such as power distribution networks, motor control systems, and the operation of general industrial machinery. Manufactured in the USA, this reactor exemplifies a commitment to stringent quality standards and dependable performance. SKU: CRX0065AC. UNSPSC Code: 39121015.
  • 600V Class Iron Core Reactor
  • 65 Amp Current Rating
  • 0.34 Henry Inductance
  • 60 Hz Operating Frequency
  • Core and Coil Construction (Iron Core)

Specifications

Amperage Rating
65 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Enclosure
Core and Coil
Frequency Rating
50/60 HZ
Height
5.63 IN
Impedance
0.03
Input Voltage
480 Volt
Length
6 IN
Mounting
Floor or Panel Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Width
7.25 IN
Package Dimensions (L x W x H)
5.63 IN x 7.25 IN x 6 IN
Package Dimensions (L x W x H)
14.3002 cm x 18.415 cm x 15.24 cm
Package Weight (Imperial)
25.000 L
Package Weight (Metric)
11.340 kg
600V Class Iron Core Reactor, Core and Coil, 65 Amps, 0.57 Inductance, 60 Hz

CRX0065BC

600V Class Iron Core Reactor, Core and Coil, 65 Amps, 0.57 Inductance, 60 Hz
KDR, 575V, 80A, 60HP

KDRF31PE3R

KDR, 575V, 80A, 60HP
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Core and Coil, 1.4 Amps, 20.36 Inductance, 60 Hz

CRX01D4AC

600V Class Iron Core Reactor, Core and Coil, 1.4 Amps, 20.36 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 2 Amps, 20.00 Inductance, 60 Hz

CRX0002CC

600V Class Iron Core Reactor, Core and Coil, 2 Amps, 20.00 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 9 Amps, 5.09 Inductance, 60 Hz

CRX0009BC

600V Class Iron Core Reactor, Core and Coil, 9 Amps, 5.09 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 1.8 Amps, 14.91 Inductance, 60 Hz

CRX01D8AC

600V Class Iron Core Reactor, Core and Coil, 1.8 Amps, 14.91 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 3 Amps, 7.06 Inductance, 60 Hz

CRX0003AC

600V Class Iron Core Reactor, Core and Coil, 3 Amps, 7.06 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What standards are HPS Centurion R reactors compliant with?

They are fully compliant with UL, CSA, CE, IEC, and NEMA standards.

What are the available impedance ratings for these reactors?

The impedance ratings available are 1.5%, 3%, and 5%.

What system voltage ratings are offered for the reactors?

System voltage ratings include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V.

What is the inductance tolerance for these reactors?

The inductance tolerance is +15/-10%.

What is the cooling method for the HPS Centurion R reactors?

The cooling method is natural convection.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What type of resin is used for VPI impregnation?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin.

What type of terminals are provided for currents below 65 Amps?

Finger-proof terminal blocks are provided on rated currents of approximately below 65 Amps.

What type of terminals are supplied for currents of 65 Amps and above?

Terminal pads are supplied on approximately 65 Amps and above, and these pads are brazed for electrical integrity.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.