Authorized Hammond Power Distributor
Hammond Power CRX0059BC - 600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz

Hammond Power CRX0059BC 600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.22 Inductance, 60 Hz

UPC: 803423117849


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0059BC is a 600V Class iron core reactor designed for industrial power quality applications. This three-phase reactor features core and coil construction, delivering a rated inductance of 0.22 Henry at 59 Amps and 60 Hz. Engineered for non-linear load applications as defined by UL 1561, CSA C22.2 No. 47, and IEEE 519, the CRX0059BC addresses harmonic distortion and current smoothing in motor control systems, variable frequency drives, and other power distribution equipment. Typical uses include power factor correction, harmonic filtering, and voltage regulation in industrial, commercial, and utility environments. The reactor's iron core construction provides stable inductance under typical load conditions, reducing electrical noise and extending equipment lifespan. With a 1.2kV class rating, this reactor is suitable for integration into control panels, switchgear, and power distribution systems requiring precise current control and harmonic mitigation.
  • 600V Class iron core reactor with core and coil construction
  • Rated 59 Amps, 0.22 Henry inductance at 60 Hz
  • Designed for non-linear load applications per UL 1561, CSA C22.2 No. 47, IEEE 519
  • Suitable for power factor correction, harmonic filtering, and current smoothing
  • Manufactured in the USA

Specifications

Amperage Rating
59 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
59 A
Enclosure
Core and Coil
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
5.63 IN
Impedance
0.03
Inductance
0.22 H
Input Voltage
240 Volt
Length
5.88 in
Material
Iron Core
Mounting
Floor or Panel Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
7.25 IN
Package Dimensions (L x W x H)
5.63 IN x 7.25 IN x 5.88 IN
Package Dimensions (L x W x H)
14.3002 cm x 18.415 cm x 14.9352 cm
Package Weight (Imperial)
18.000 L
Package Weight (Metric)
8.165 kg
600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.36 Inductance, 60 Hz

CRX0059DC

600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.36 Inductance, 60 Hz
KDR, 575V, 80A, 60HP

KDRF31PE3R

KDR, 575V, 80A, 60HP
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Core and Coil, 170 Amps, 0.10 Inductance, 60 Hz, 5 PCT Impedance at 240 Volt

CRX0170CC

600V Class Iron Core Reactor, Core and Coil, 170 Amps, 0.10 Inductance, 60 Hz, 5 PCT Impedance at 240 Volt
600V Class Iron Core Reactor, Core and Coil, 62 Amps, 0.45 Inductance, 60 Hz

CRX0062AC

600V Class Iron Core Reactor, Core and Coil, 62 Amps, 0.45 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 143 Amps, 0.10 Inductance, 60 Hz

CRX0143BC

600V Class Iron Core Reactor, Core and Coil, 143 Amps, 0.10 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.30 Inductance, 60 Hz

CRX0059CC

600V Class Iron Core Reactor, Core and Coil, 59 Amps, 0.30 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.09 Inductance, 60 Hz

CRX0114AC

600V Class Iron Core Reactor, Core and Coil, 114 Amps, 0.09 Inductance, 60 Hz

Frequently Asked Questions

What is the cooling method for the HPS Centurion R reactors?

The cooling method is natural convection.

What is the power rating range for HPS Centurion R reactors?

The HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by the HPS Centurion R reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The HPS Centurion R reactors are available with impedance ratings of 1.5%, 3%, and 5%.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

What type of terminals are provided on reactors below 65 Amps?

Finger-proof terminal blocks are provided on rated currents of approximately below 65 Amps.

What type of terminals are provided on reactors at or above 65 Amps?

Terminal pads are supplied on approximately 65 Amps and above, and these pads are brazed to ensure electrical integrity.

What is the insulation system's temperature rise for units larger than 40A?

For units larger than 40A, there is a 115ºC rise over average 50°C ambient for 180ºC and 220ºC Temperature Classes.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

How does the HPS Centurion R reactor protect motors and AC drives?

It protects motors and AC drives by attenuating voltage and current transients, minimizing power system harmonics, and reducing harmonic current levels.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.