Authorized Hammond Power Distributor
Hammond Power CRX0046CE - 600V Class Iron Core Reactor, Enclosed, 46 Amps, 0.36 Inductance, 60 Hz

Hammond Power CRX0046CE 600V Class Iron Core Reactor, Enclosed, 46 Amps, 0.36 Inductance, 60 Hz

UPC: 803423120221


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0046CE is an enclosed 600V Class Iron Core Reactor, designed for reliable performance in industrial power systems. This unit features a robust 46 Amp current rating and a precise 0.36 Henry inductance, operating efficiently at a standard 60 Hz frequency. Manufactured in the USA, the CRX0046CE is built for stability and longevity in demanding applications. Its primary functions include power factor correction, harmonic filtering, and motor control, where precise current and voltage regulation are essential for optimal system operation. The fully enclosed design safeguards internal components, ensuring consistent performance and extending the product's lifespan within industrial environments. Trust Hammond Power's commitment to quality for your critical power infrastructure needs. SKU: CRX0046CE. UNSPSC: 39121015.
  • 600V Class Voltage Rating
  • 46 Amp Current Rating
  • 0.36 Henry Inductance
  • 60 Hz Frequency
  • Fully Enclosed Design
  • Manufactured in the USA

Specifications

Amperage Rating
46 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Current Rating
46 A
Enclosure
N1-N1/IP20 - Indoor
Enclosure Type
Enclosed
Frequency
60 Hz
Frequency Rating
50/60 HZ
Height
8.13 in
Impedance
0.05
Inductance
0.36 H
Input Voltage
208 Volt
Length
10 IN
Material
Iron Core
Mounting
Floor or Panel Mount
Mounting Type
Enclosed
Noise Level
Between 58dBA to 75 dBA
Phase
3
Series
CRX
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Voltage Rating
600 V
Width
10 IN
Package Dimensions (L x W x H)
8.13 IN x 10 IN x 10 IN
Package Dimensions (L x W x H)
20.6502 cm x 25.4 cm x 25.4 cm
Package Weight (Imperial)
16.500 L
Package Weight (Metric)
7.484 kg
600V Class Iron Core Reactor, Enclosed, 46 Amps, 0.21 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt

CRX0046BE

600V Class Iron Core Reactor, Enclosed, 46 Amps, 0.21 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt
KLR, 480V, 35A, 20HP

KLR35CTB

KLR, 480V, 35A, 20HP
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Enclosed, 11 Amps, 2.10 Inductance, 60 Hz

CRX0011BE

600V Class Iron Core Reactor, Enclosed, 11 Amps, 2.10 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 124 Amps, 0.19 Inductance, 60 Hz

CRX0124AE

600V Class Iron Core Reactor, Enclosed, 124 Amps, 0.19 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 75 Amps, 0.19 Inductance, 60 Hz

CRX0075BE

600V Class Iron Core Reactor, Enclosed, 75 Amps, 0.19 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 114 Amps, 0.19 Inductance, 60 Hz

CRX0114DE

600V Class Iron Core Reactor, Enclosed, 114 Amps, 0.19 Inductance, 60 Hz
600V Class Iron Core Reactor, Enclosed, 143 Amps, 0.10 Inductance, 60 Hz

CRX0143BE

600V Class Iron Core Reactor, Enclosed, 143 Amps, 0.10 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What are the available impedance ratings for the reactors?

The available impedance ratings for the reactors are 1.5%, 3%, and 5%.

How do HPS reactors improve motor performance and longevity?

By moderating line transients, HPS reactors reduce motor operating temperature and audible noise, enhancing overall system performance and motor life expectancy.

What is the purpose of VPI impregnation in these reactors?

Every reactor is vacuum pressure impregnated with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What type of terminal connections are provided on the reactors?

Finger-proof terminal blocks are provided on currents below 65 Amps, and terminal pads are supplied on 65 Amps and above.

What is the inductance tolerance for these reactors?

The inductance tolerance for the reactors is +15/-10%.

What is the cooling method for the HPS Centurion R reactors?

The reactors are cooled using natural convection.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

What standards are the HPS Centurion R reactors certified to?

They are certified to UL 508, CSA C9, CSA C22.2 No. 47, CE Mark (IEC 61558-2-20:2000), UL Listed (up to 600 V), CSA Certified, and IEC 61558-2-20.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.