Authorized Hammond Power Distributor
Hammond Power CRX0021NE - Reactors, 21 Amperes, 2.14 Millihenries Inductance, 50 Hertz, Enclosed.
More images

Hammond Power CRX0021NE Reactors, 21 Amperes, 2.14 Millihenries Inductance, 50 Hertz, Enclosed.

UPC: 803423149574


Documents & Media
BrochureInstallation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0021NE is an enclosed reactor from the HPS Centurion™ R series, designed to enhance performance and reliability in industrial applications. This unit features a current rating of 21 Amperes and an inductance of 2.14 millihenries, operating at a frequency of 50 Hertz. Its enclosed design offers protection and facilitates easier integration into control panels and electrical enclosures. The HPS Centurion™ R series is recognized for its ability to reduce product footprint while maintaining robust operational capabilities. This reactor is suitable for applications requiring precise current control and harmonic mitigation, contributing to the overall efficiency and longevity of connected equipment. Manufactured in the US, the CRX0021NE (SKU: CRX0021NE) adheres to high manufacturing standards. Its UNSPSC code is 39121015, indicating its classification within electrical power quality and control equipment. The compact and enclosed nature of this reactor makes it an ideal choice for space-constrained environments where reliable electrical conditioning is paramount. It serves as a critical component in power systems, ensuring stable operation and protecting sensitive electronics from electrical disturbances.
  • The efficient and cost effective HPS Centurion™ R reactors are built to address both line-side and load-side issues associated with demanding AC drive applications.
  • HPS Centurion™ R reactors deliver protection for your motors and drives.
  • They are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (745 kilowatts), up to 600 V (690 V with de-rating) and are fully compliant with UL, CSA, CE, IEC, and NEMA standards.
  • Enclosed design for protection
  • HPS Centurion™ R series for improved performance and reliability

Specifications

Current Rating
21 A
Frequency
50 Hz
Series
HPS Centurion™ R
Package Dimensions (L x W x H)
8 IN x 10 IN x 8.13 IN
Package Dimensions (L x W x H)
203 mm x 254 mm x 206 mm
Package Weight (Imperial)
17.000 L
Package Weight (Metric)
7.800 kg
Reactors, 21 Amperes, 1.81 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.

CRX0021NC

Reactors, 21 Amperes, 1.81 Millihenries Inductance, 50 Hertz, Copper Windings, Core and Coil.
KDR, 208V, 25A, 7.5HP

KDRB23LE01

KDR, 208V, 25A, 7.5HP
REACTOR LRW130G3N1

LRW130G3N1

REACTOR LRW130G3N1
Reactors, 3 Amperes, 10.61 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0003PE

Reactors, 3 Amperes, 10.61 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 8 Amperes, 2.569 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0008NE

Reactors, 8 Amperes, 2.569 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 130 Amperes, 0.3475 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0130NE

Reactors, 130 Amperes, 0.3475 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 3 Amperes, 7.058 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0003NE

Reactors, 3 Amperes, 7.058 Millihenries Inductance, 50 Hertz, Enclosed.
Reactors, 23 Amperes, 1.061 Millihenries Inductance, 50 Hertz, Enclosed.

CRX0023NE

Reactors, 23 Amperes, 1.061 Millihenries Inductance, 50 Hertz, Enclosed.

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in standard ratings from 0.5 HP (373 Watts) to 1000 HP (746 kilowatts).

What system voltages are supported by HPS Centurion R reactors?

Supported system voltages include 120 V, 208 V, 240 V, 480 V, 600 V, and 690 V at 60 Hz, and 380 V, 525 V, and 690 V at 50 Hz.

What are the available impedance ratings for these reactors?

The available impedance ratings are 1.5%, 3%, and 5%.

What is the inductance tolerance for HPS Centurion R reactors?

The inductance tolerance is +15/-10%.

How are HPS Centurion R reactors cooled?

The reactors are cooled using natural convection.

What is the warranty period for HPS Centurion R reactors?

HPS Centurion R reactors come with a 10-year limited warranty.

What standards are HPS Centurion R reactors compliant with?

They are compliant with UL, CSA, CE, IEC, and NEMA standards.

What is the dielectric strength to ground for these reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

How are the reactors constructed to minimize audible noise?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What is the purpose of using an HPS Centurion R reactor?

Reactors protect motors and AC drives, minimize power system harmonics, attenuate voltage and current transients, and reduce motor operating temperature and audible noise.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.