Hammond Power CRX0017AC - 600V Class Iron Core Reactor, Core and Coil, 17 Amps, 1.66 Inductance, 60 Hz

Hammond Power CRX0017AC 600V Class Iron Core Reactor, Core and Coil, 17 Amps, 1.66 Inductance, 60 Hz

UPC: 803423117474


Documents & Media
BrochureTechnical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power CRX0017AC is a 600V Class Iron Core Reactor, essential for industrial power applications. This reactor features a robust core and coil construction, rated for 17 Amps and providing an inductance of 1.66 Henry at a 60 Hz operating frequency. Its design ensures reliable performance in critical power systems, motor control circuits, and harmonic filtering applications. The CRX0017AC is suitable for industrial power distribution, renewable energy integration, and general electrical infrastructure where precise inductance and current handling are vital. Manufactured in the USA by Hammond Power, this reactor (SKU: CRX0017AC) adheres to stringent performance standards for efficiency and durability. Its construction is optimized for consistent operation and longevity in demanding industrial environments. The UNSPSC code for this product is 39121015.
  • 600V Class Iron Core Reactor
  • 17 Amps Current Rating
  • 1.66 Henry Inductance
  • 60 Hz Operating Frequency
  • Core and Coil Construction

Specifications

Amperage Rating
17 Amp
Application
Oil & Gas, Irrigation Fields, Wastewater, Food Processing, HVAC, Automotive
Enclosure
Core and Coil
Frequency Rating
50/60 HZ
Height
6.13 in
Impedance
0.03
Input Voltage
600 Volt
Length
5 IN
Mounting
Floor or Panel Mount
Noise Level
Between 58dBA to 75 dBA
Phase
3
Special Features
Innovative design showcases a unique blend of performance and economy to protect your VFD, motor, capacitors and electrical system from harmonics, damage and nuisance tripping.
Standard
csa, ul, ce
Type
Reactors > Air Core > Centurion R series
Width
6.5 IN
Package Dimensions (L x W x H)
6.13 IN x 6.5 IN x 5 IN
Package Dimensions (L x W x H)
15.5702 cm x 16.51 cm x 12.7 cm
Package Weight (Imperial)
3.000 L
Package Weight (Metric)
1.361 kg
600V Class Iron Core Reactor, Core and Coil, 17 Amps, 2.73 Inductance, 60 Hz

CRX0017BC

600V Class Iron Core Reactor, Core and Coil, 17 Amps, 2.73 Inductance, 60 Hz
KDR, 600/600V, 10HP, 11 Motor Amps

KDRAA49L2

KDR, 600/600V, 10HP, 11 Motor Amps
REACTOR LRW130D3N1

LRW130D3N1

REACTOR LRW130D3N1
600V Class Iron Core Reactor, Core and Coil, 27 Amps, 1.77 Inductance, 60 Hz

CRX0027DC

600V Class Iron Core Reactor, Core and Coil, 27 Amps, 1.77 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 27 Amps, 1.06 Inductance, 60 Hz

CRX0027AC

600V Class Iron Core Reactor, Core and Coil, 27 Amps, 1.06 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 31 Amps, 0.32 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt

CRX0031BC

600V Class Iron Core Reactor, Core and Coil, 31 Amps, 0.32 Inductance, 60 Hz, 3 PCT Impedance at 208 Volt
600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.41 Inductance, 60 Hz

CRX0024AC

600V Class Iron Core Reactor, Core and Coil, 24 Amps, 0.41 Inductance, 60 Hz
600V Class Iron Core Reactor, Core and Coil, 31 Amps, 0.55 Inductance, 60 Hz

CRX0031CC

600V Class Iron Core Reactor, Core and Coil, 31 Amps, 0.55 Inductance, 60 Hz

Frequently Asked Questions

What is the power rating range for HPS Centurion R reactors?

HPS Centurion R reactors are available in ratings from 0.5 HP (373 Watts) to 1250 HP (932 kW).

What system voltages are supported by these reactors?

The reactors support system voltages of 120 V, 208 V, 240 V, 380 V, 480 V, 525 V, 600 V, and 690 V.

What are the available impedance ratings for the reactors?

The impedance ratings available for the HPS Centurion R reactors are 1.5%, 3%, and 5%.

How are the reactors protected against audible noise?

Every reactor is vacuum pressure impregnated (VPI) with VT (vinyl-toluene) Polyester Resin to minimize audible noise.

What types of terminals are provided on the reactors?

Finger-proof terminal blocks are provided on currents below approximately 65 Amps, and terminal pads are supplied on 65 Amps and above.

What are the benefits of using an HPS Centurion R reactor?

Benefits include mitigating nuisance tripping, extending motor life, reducing noise and operating temperature, and minimizing harmonic distortion.

What is the inductance tolerance for these reactors?

The inductance tolerance for the HPS Centurion R reactors is +15/-10%.

What is the dielectric strength to ground for the reactors?

The dielectric strength to ground is 4000 volts for 1 minute or equivalent.

What is the cooling method for the HPS Centurion R reactors?

The cooling method used is natural convection.

What is the warranty period for the HPS Centurion R reactors?

The HPS Centurion R reactors come with a 10-year limited warranty.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.