Hammond Power CP1P6G0073CC - Passive Harmonic Filters, 75 HorsePower, 600 Volts, 73 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1P6G0073CC

UPC: 803423190606


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CP1P6G0073CC is a passive harmonic filter designed to mitigate harmonic distortion in industrial electrical systems. This unit is rated for 75 Horsepower, operates at 600 Volts, and handles a continuous current of 73 Amperes at a 60 Hertz frequency. Its robust construction features an Enclosure Type 3R, making it suitable for outdoor or washdown environments. The advanced HPS design significantly reduces harmonic current distortion, typically achieving reductions of 80% and bringing distortion levels to 5% or less at full load. This superior performance ensures compliance with IEEE 519 harmonic standards when operated within its designed parameters. Furthermore, the filter actively corrects the true power factor, elevating it to over 95%. This results in improved system efficiency and reduced energy costs. The inclusion of a contactor simplifies integration into existing control panels. Manufactured by Hammond Power in the USA, this filter (SKU: CP1P6G0073CC) offers a reliable solution for power quality challenges in various industrial applications, including motor control and machinery operation. Its passive design ensures a long service life with minimal maintenance requirements.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Enclosure Type 3R for outdoor or washdown applications

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Current Rating
73 A
Depth
14.8 IN
Enclosure
Type 3R DH3
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
25.2 IN
Impedance
73A
Input Current
68 A
Length
27 IN
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
73 A
Series
CP1P
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
600 V
Voltage Rating
600 V
Voltage Rating
600V
Warranty
3 Years
Weight
350 L
Width
12.5 IN
Package Dimensions (L x W x H)
14.8 IN x 12.5 IN x 25.2 IN
Package Dimensions (L x W x H)
376 mm x 318 mm x 648 mm
Package Weight (Imperial)
350.000 L
Package Weight (Metric)
159.000 kg
Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0096CC

Passive Harmonic Filters, 100 HorsePower, 600 Volts, 96 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0120CC

Passive Harmonic Filters, 125 HorsePower, 600 Volts, 120 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0059CC

Passive Harmonic Filters, 60 HorsePower, 600 Volts, 59 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 150 HorsePower, 600 Volts, 144 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0144CC

Passive Harmonic Filters, 150 HorsePower, 600 Volts, 144 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0049CC

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0192CC

Passive Harmonic Filters, 200 HorsePower, 600 Volts, 192 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0049C

Passive Harmonic Filters, 50 HorsePower, 600 Volts, 49 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0040CC

Passive Harmonic Filters, 40 HorsePower, 600 Volts, 40 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0074C

Passive Harmonic Filters, 60 HorsePower, 480 Volts, 74 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0061CC

Passive Harmonic Filters, 50 HorsePower, 480 Volts, 61 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0240CC

Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0031CC

Passive Harmonic Filters, 30 HorsePower, 600 Volts, 31 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

Frequently Asked Questions

What is the purpose of this passive harmonic filter?

The passive harmonic filter improves power quality by reducing harmonic current distortion by 80% (typically to 5% or less at full load) and correcting true power factor to over 95%. It helps mitigate harmonics created by non-linear loads like variable frequency drives.

What voltage ratings are available for this filter?

The filter is available in two voltage ratings: 480VAC (+/-10%) and 600VAC (+/-10%), with current ranges from 6A to 632A, covering 5 to 500 horsepower applications.

What are the operating temperature requirements?

The filter has an ambient operating temperature range up to 50°C, with maximum humidity of 95% non-condensing. Storage temperature is -20°C to +60°C.

What is the warranty for this product?

The passive harmonic filter comes with a 3-year warranty.

What harmonics does this filter mitigate?

The filter is engineered to reduce the 5th, 7th, 11th, 13th, and higher order harmonics in three-phase power systems, particularly those created by 6-pulse rectifiers.

What are the potential consequences of harmonic distortion?

Harmonic distortion can cause overheating of electrical equipment, loss of efficiency, nuisance tripping, premature equipment failure, and interference with communication systems.

What is the efficiency of the harmonic filter?

The filter has an efficiency of no less than 99% at full load and can handle 150% of rated current for 1 minute.

What industries benefit from this harmonic filter?

Critical industries like chemical processing, data centers, HVAC systems, material handling, mining, oil & gas, pulp & paper, hospitals, wastewater treatment plants, and EV charging can benefit from this filter.

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift or hoisting equipment

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Position the filter using a forklift or hoisting equipment, ensuring it is securely mounted in accordance with local codes. Maintain at least 6 inches of clearance from walls and other obstructions for ventilation.

  3. Ground the filter

    Connect the designated main grounding location of the filter to a proper ground to ensure safe operation before energizing the unit.

  4. Make electrical connections

    Connect the input and output terminals of the filter as per the nameplate diagram. Ensure that A1, B1, and C1 are connected to the power supply, and A2, B2, and C2 are connected to the load.

  5. Verify connections

    Use a multimeter to verify that all electrical connections are secure and properly grounded before energizing the filter.

  6. Energize the filter

    Once all connections are verified, turn on the upstream circuit breaker or disconnect to energize the filter. Monitor for any unusual sounds or indicators.

  7. Perform initial testing

    Use a power quality analyzer to measure baseline parameters such as total harmonic distortion and power factor before and after connecting the filter to ensure it is functioning correctly.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.