Authorized Hammond Power Distributor
Hammond Power CP1K6G0037CC - Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
More images

Hammond Power CP1K6G0037CC Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Enclosure Type…

UPC: 803423190132


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Hammond Power HPS Passive Harmonic Filter, SKU CP1K6G0037CC, is engineered to significantly mitigate harmonic distortion in industrial electrical systems. Designed for 30 HorsePower (HP) applications, this filter operates at 480 Volts (V) and a current rating of 37 Amperes (A) with a frequency of 60 Hertz (Hz). Its advanced HPS design offers superior performance over traditional harmonic filters, typically reducing harmonic current distortion by 80%, bringing it to 5% or less at full load. This level of harmonic reduction ensures compliance with IEEE 519 harmonic requirements when operated within its designed parameters. Furthermore, the filter corrects the true power factor to over 95%, enhancing system efficiency and reducing energy costs. The enclosure is rated Type 3R, providing protection against falling rain and sleet, making it suitable for outdoor or exposed installations. This unit includes a contactor for integrated control. Manufactured in the USA, this passive harmonic filter is a reliable solution for maintaining power quality in demanding industrial environments. Its UNSPSC code is 83101808.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/exposed installations

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Connection Type
Contactor
Cooling
Natural Convection
Current Rating
37 A
Depth
23.8 IN
Enclosure
Type 3R DH2
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
28.8 IN
Impedance
37A
Input Current
34 A
Length
23.8 IN
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
37 A
Series
CP1K6G
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
180 L
Width
25.8 IN
Package Dimensions (L x W x H)
23.8 IN x 25.8 IN x 28.8 IN
Package Dimensions (L x W x H)
604 mm x 655 mm x 731 mm
Package Weight (Imperial)
180.000 L
Package Weight (Metric)
82.000 kg
Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0037C

Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Enclosure Type 3R
DigiBOX B-30 ND RS 240V STEEL

USDBP01ND0

DigiBOX B-30 ND RS 240V STEEL
Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0037FC

Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0032FC

Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1P6G0240CC

Passive Harmonic Filters, 250 HorsePower, 600 Volts, 240 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
dV/dT filter 108 amperes up to 600 volts open style 1000 feet

CD1X0108F1

dV/dT filter 108 amperes up to 600 volts open style 1000 feet
dV/dT filter 22 amperes up to 600 volts open style 1000 feet

CD1X0022F1

dV/dT filter 22 amperes up to 600 volts open style 1000 feet
dV/dT filter 65 amperes up to 600 volts open style 1000 feet

CD1X0065F1

dV/dT filter 65 amperes up to 600 volts open style 1000 feet

Frequently Asked Questions

What is the primary function of the HPS passive harmonic filter?

The HPS passive harmonic filter improves power quality by reducing harmonics and improving true power factor, meeting IEEE 519 requirements.

What types of loads cause harmonic distortion?

Harmonic distortion is caused by non-linear loads such as variable frequency drives (VFDs), DC drives, chargers, rectifiers, and induction heating systems.

What are the consequences of harmonic distortion?

Harmonic distortion can lead to overheating of electrical equipment, loss of efficiency, nuisance tripping, premature equipment failure, and interference with communication systems.

What range of horsepower is the HPS passive harmonic filter available in?

The HPS passive harmonic filter is available for applications ranging from 5 to 1500 horsepower.

What specific harmonics does the HPS passive harmonic filter mitigate?

The filter is engineered to reduce the 5th, 7th, 11th, and 13th harmonics, as well as higher orders in three-phase power systems.

How does the filter affect power factor and efficiency?

It corrects true power factor to over 95% and improves system efficiency, lowering kW and kVA.

Is the HPS passive harmonic filter compatible with generator-fed systems?

Yes, its kVAr ratings are limited to no more than 20% of the filter’s kVA, ensuring compatibility with generator-fed systems.

What are the available voltage ratings for the HPS passive harmonic filter?

The filter is available in 480VAC or 600VAC voltage ratings, with a +/-10% tolerance.

What is the typical total harmonic current distortion (THDi) reduction at full load?

Total harmonic current distortion is typically reduced by 80%, to 5% or less at full load.

What is the ambient operating temperature range for this filter?

The filter can operate in ambient temperatures up to 50°C.

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Secure the HPS Centurion P Passive Harmonic Filter to a suitable location using the provided mounting brackets. Ensure that there is adequate clearance for ventilation and access.

  3. Connect the wiring

    Connect the input and output wiring to the terminals marked A1, B1, C1 for the power supply and A2, B2, C2 for the load. Ensure all connections are tight and comply with local electrical codes.

  4. Ground the filter

    Properly ground the Passive Harmonic Filter by connecting a grounding wire to the designated grounding location on the unit. Verify that the ground connection is secure.

  5. Power on and test

    Turn on the power supply to the filter and use a multimeter to verify that the input voltage is within 5% of the nameplate voltage. Check for any abnormal sounds or overheating.

  6. Commissioning

    Perform initial testing using a power quality analyzer to measure total harmonic distortion and power factor. Document the readings for future reference.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.