Hammond Power CP1K6G0032FC - Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Open Style, Contactor
Hammond Power

CP1K6G0032FC

UPC: 803423190125


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Passive Harmonic Filter, SKU CP1K6G0032FC, is engineered to mitigate harmonic distortion in industrial electrical systems. Designed for 25 HorsePower applications at 480 Volts and 32 Amperes, this 60 Hertz filter operates effectively within its specified parameters. Its advanced HPS design significantly reduces harmonic current distortion, typically achieving reductions of 80% and bringing distortion levels to 5% or less at full load. This superior performance corrects the true power factor to over 95%, ensuring efficient power utilization. Crucially, this passive harmonic filter meets the stringent IEEE 519 harmonic requirements when operated within its designed parameters. The open-style construction allows for straightforward integration into existing control panels and electrical enclosures. Manufactured in the US, this filter provides a reliable solution for improving power quality and system reliability in demanding industrial environments. Its UNSPSC code is 83101808.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Open Style construction for easy integration

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Depth
20.1 IN
Enclosure
Open Frame
Enclosure Type
Open Style
Frequency
60Hz
Frequency Rating
60 HZ
Height
22 IN
Impedance
32A
Input Current
29 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
Output Current
32 A
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
170 L
Width
21.5 IN
Package Dimensions (L x W x H)
20.1 IN x 21.5 IN x 22 IN
Package Dimensions (L x W x H)
510 mm x 546 mm x 559 mm
Package Weight (Imperial)
170.000 L
Package Weight (Metric)
77.000 kg
Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0025FC

Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0019FC

Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0014FC

Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0011FC

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0025FC

Passive Harmonic Filters, 25 HorsePower, 600 Volts, 25 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0020FC

Passive Harmonic Filters, 20 HorsePower, 600 Volts, 20 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0008FC

Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0012FC

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0008FC

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0006FC

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style, Contactor

CP1K6G0037FC

Passive Harmonic Filters, 30 HorsePower, 480 Volts, 37 Amperes, 60 Hertz, Open Style, Contactor
Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0032CC

Passive Harmonic Filters, 25 HorsePower, 480 Volts, 32 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring proper wiring and configuration for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the HPS Centurion P Passive Harmonic Filter, inspect it for any transit damage and verify it against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Using a forklift, carefully lift the filter and position it in the designated installation location, ensuring at least 6 inches of clearance around all ventilated sides. Secure the unit using the provided mounting screws.

  3. Connect the wiring

    Connect the power supply to the filter by wiring phases A1, B1, and C1 to the corresponding phases of the power supply, and A2, B2, and C2 to the load. Ensure all connections are tight and secure.

  4. Ground the filter

    Connect the designated main grounding location of the filter to a suitable ground. Verify that all ground connections are secure before proceeding.

  5. Commission the system

    Before energizing the filter, ensure that all connections are correct and secure. Use a multimeter to confirm that there is no voltage present at the terminals. Once confirmed, energize the system and monitor for proper operation.

  6. Perform initial testing

    After the filter is energized, use a power quality analyzer to measure total harmonic distortion and power factor. Document the readings for future reference.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.