Hammond Power CP1K6G0011CC - Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Hammond Power

CP1K6G0011CC

UPC: 803423190033


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Passive Harmonic Filter, SKU CP1K6G0011CC, is engineered to significantly mitigate harmonic distortion in industrial power systems. This unit is rated for 7.5 HorsePower, operates at 480 Volts and 60 Hertz, with a maximum current rating of 11 Amperes. Its advanced HPS design offers superior performance over traditional harmonic filters, typically reducing harmonic current distortion by 80%, bringing it to 5% or less at full load. This level of harmonic reduction ensures compliance with stringent standards like IEEE 519 when operated within its designed parameters. Furthermore, the filter corrects the true power factor to over 95%, enhancing system efficiency and reducing energy costs. The enclosure is rated Type 3R, providing protection against falling rain and sleet, making it suitable for outdoor or exposed industrial environments. Integrated with a contactor for control and switching, this passive harmonic filter is a reliable solution for improving power quality and system reliability in various industrial applications.
  • The HPS passive harmonic filter is specifically engineered to mitigate harmonic currents created by non-linear loads.
  • It is currently available from 5 to 500 horsepower and it improves power quality by simultaneously reducing harmonics and improving true power factor.
  • HPS passive harmonic filters consists of reactors and capacitors in an LCL arrangement designed to reduce a broad range of harmonics associated with variable frequency drives and other three phase rectifiers.
  • Typical Power Factor: >95%
  • Type 3R enclosure for outdoor/exposed environments

Specifications

Ambient Operating Temperature
0 to 40 Deg C
Application
For applications requiring IEEE-519 compliant power systems such as chemical processing, data centers, HVAC systems, material handling, hospitals, and wastewater treatment plants
Cooling
Natural Convection
Current Rating
11 A
Depth
20.1 IN
Enclosure
Type 3R DH1
Enclosure Type
Type 3R
Frequency
60Hz
Frequency Rating
60 HZ
Height
22 IN
Impedance
11A
Input Current
9 A
Length
20.1 in
Mounting
Wall/Ceiling/Floor Mount
Mounting Style
Floor
NEMA Rating
Type 3R
Output Current
11 A
Series
CP1K
Special Features
Delivers superior performance compared to traditional harmonic filters by reducing harmonic current distortion to less than 5% and correcting true power factor to over 95%, enabling users to meet IEEE 519 harmonic requirements.
Standard
cUL Listed (E61431)
Voltage
480 V
Voltage Rating
480 V
Voltage Rating
480V
Warranty
3 Years
Weight
120 lbs
Width
21.5 in
Package Dimensions (L x W x H)
20.1 IN x 21.5 IN x 22 IN
Package Dimensions (L x W x H)
510 mm x 546 mm x 559 mm
Package Weight (Imperial)
120.000 L
Package Weight (Metric)
50.000 kg
Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0011C

Passive Harmonic Filters, 7.5 HorsePower, 480 Volts, 11 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower 480V 8 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0008C

Passive Harmonic Filters, 5 HorsePower 480V 8 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0012C

Passive Harmonic Filters, 10 HorsePower, 600 Volts, 12 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0008CC

Passive Harmonic Filters, 5 HorsePower, 480 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0014CC

Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0014C

Passive Harmonic Filters, 10 HorsePower, 480 Volts, 14 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0019C

Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0006C

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0019CC

Passive Harmonic Filters, 15 HorsePower, 480 Volts, 19 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R

CP1P6G0008C

Passive Harmonic Filters, 7.5 HorsePower, 600 Volts, 8 Amperes, 60 Hertz, Enclosure Type 3R
Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor

CP1K6G0025CC

Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R, Contactor
Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R

CP1K6G0025C

Passive Harmonic Filters, 20 HorsePower, 480 Volts, 25 Amperes, 60 Hertz, Enclosure Type 3R

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Forklift (if necessary)

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the Passive Harmonic Filter, inspect it for any transit damage and verify against the shipping documents. If any damage is noted, file a claim with the carrier.

  2. Mount the filter

    Secure the Passive Harmonic Filter to a stable surface or DIN rail using the provided mounting brackets and screws. Ensure the unit is level and has sufficient clearance for ventilation.

  3. Ground the filter

    Connect the designated main grounding location of the Passive Harmonic Filter to a suitable ground to ensure safe operation before energizing the unit.

  4. Wire the connections

    Connect the input and output terminals of the filter (A1, B1, C1 for input and A2, B2, C2 for output) to the corresponding phases of the power supply and load, ensuring all connections are tight and secure.

  5. Verify connections

    Use a multimeter to verify that all electrical connections are correct and that there is no voltage present before proceeding to energize the unit.

  6. Energize the filter

    Once all connections are verified and secure, turn on the upstream circuit breaker or disconnect to energize the Passive Harmonic Filter.

  7. Perform initial testing

    Use a power quality analyzer to measure total harmonic distortion and power factor before and after connecting the filter to ensure it is functioning correctly.

  8. Calibrate if necessary

    If the initial testing shows discrepancies, adjust the filter settings or connections as needed and retest to confirm proper operation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.