Hammond Power CD1X0200E1 - dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
Hammond Power

CD1X0200E1

UPC: 803423203559


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Solutions (HPS) CD1X0200E1 dV/dT filter (SKU: CD1X0200E1) is a Type 1-rated industrial solution engineered to protect motors and associated cabling in variable frequency drive (VFD) applications, particularly those with extended cable lengths. This filter is rated for a continuous current of 130 amperes and can operate with systems up to 600 volts. Its primary function is to mitigate the damaging voltage spikes (dV/dT) generated by VFDs. These spikes can significantly stress motor insulation, leading to premature failure and increased maintenance costs. By attenuating these voltage transients, the CD1X0200E1 effectively extends the operational lifespan of motors and cables. It is an ideal component for installations where cable runs between the VFD and the motor exceed standard lengths, helping to maintain system integrity and compliance with standards such as IEEE 519 for harmonic distortion. The filter is UL-listed, ensuring its suitability for demanding industrial environments and reliable performance under harsh operating conditions. Designed for compatibility with standard VFD-motor configurations, it requires straightforward installation and wiring without complex configuration. Manufactured in France, the HPS CD1X0200E1 offers a cost-effective approach to reducing downtime and maintenance expenditures in motor-driven systems.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Ideal for VFD applications with long cable runs
  • UL-listed for reliable performance and safety

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
200 A
Current Rating
130 A
Enclosure Type
Type 1
Height
17.9 in
Length
16.5 in
Maximum Operating Temperature
40 C
Mounting Type
Panel Mount
NEMA Rating
Type 1
Series
CD1X
Standard
cUL
Type
dV/dT Filter
Voltage Drop
Less than 3%
Voltage Rating
480/600 V
Voltage Rating
600 V
Weight
96 lbs
Width
23.5 in
Package Dimensions (L x W x H)
16.5 IN x 23.5 IN x 17.9 IN
Package Dimensions (L x W x H)
419.1 mm x 596.9 mm x 454.66 mm
Package Weight (Imperial)
96.000 L
Package Weight (Metric)
43.545 kg
dV/dT filter 160 amperes up to 600 volts Type 1 1000 feet

CD1X0160E1

dV/dT filter 160 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0130E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
Active Harmonic Filter 480V 100A 60Hz ETH/IP type 1;used on 600V w/auto

WAHF1K100A-I6P1

Active Harmonic Filter 480V 100A 60Hz ETH/IP type 1;used on 600V w/auto
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0250E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0305E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0365E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0415E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0515E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
Active Harmonic Filter 240V 150A 60Hz ETH type 1

WAHF1D150A

Active Harmonic Filter 240V 150A 60Hz ETH type 1
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0600E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet

CD1X0750E1

dV/dT filter 130 amperes up to 600 volts Type 1 1000 feet
Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style, Contactor

CP1P6G0006FC

Passive Harmonic Filters, 5 HorsePower, 600 Volts, 6 Amperes, 60 Hertz, Open Style, Contactor

How to Install the dV/dT Filter

This guide provides step-by-step instructions for the installation and initial setup of the dV/dT filter, ensuring safe and effective operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Inspect the unit

    Immediately after receiving the dV/dT filter, inspect it for any transit damage and ensure it matches the shipping documents. Report any damages to the carrier.

  2. Mount the filter

    Secure the dV/dT filter to a clean, dry area using appropriate mounting hardware. Ensure it is positioned for adequate ventilation and free air circulation.

  3. Connect wiring

    Connect the output phases U, V, and W from the variable frequency drive to terminals A1, B1, and C1 on the dV/dT filter. Connect T1, T2, and T3 of the motor to terminals A2, B2, and C2.

  4. Ground the filter

    Ensure the dV/dT filter is properly grounded according to local codes and standards. Verify all ground connections are secure before energizing the unit.

  5. Verify connections

    Before energizing, check all electrical connections for tightness and ensure there are no exposed wires. Use a multimeter to confirm power is off.

  6. Energize the filter

    Once all connections are verified and secure, restore power to the dV/dT filter. Monitor for any unusual sounds or overheating during initial operation.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.