Hammond Power CD1X0108F1 - dV/dT filter 108 amperes up to 600 volts open style 1000 feet
Hammond Power

CD1X0108F1

UPC: 803423190002


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power CD1X0108F1 dV/dT filter is engineered to mitigate voltage spikes and reduce motor insulation stress when used with Variable Frequency Drives (VFDs) and motors, particularly in applications with extended cable lengths. This open-style filter is rated for 108 amperes and operates up to 600 volts, providing essential protection for motor windings and extending motor lifespan. Its design is optimized for installation between the VFD output and the motor, effectively suppressing high-frequency voltage transients that can degrade motor insulation over time. The 1000-foot rating indicates its suitability for longer motor lead lengths where voltage reflection can become a significant issue. By attenuating these damaging voltage spikes, the CD1X0108F1 helps prevent premature motor failure, reduces maintenance costs, and ensures reliable operation of motor-driven systems. This filter is a critical component for applications utilizing VFDs in industrial settings, such as pump control, fan operation, and conveyor systems, where motor longevity and performance are paramount. Manufactured by Hammond Power, a trusted name in power quality solutions, the CD1X0108F1 (SKU: CD1X0108F1) offers a robust solution for protecting valuable motor assets.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Open style construction
  • Suitable for 1000 feet cable lengths

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
108 A
Enclosure
Open Frame
Height
44 IN
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Length
16 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
Peak Voltage
at Motor: 150% of DC bus voltage
Standard
cUL
Voltage Rating
up to 600V
Weight
1000 lbs
Width
23 IN
Package Dimensions (L x W x H)
7.5 IN x 9 IN x 7 IN
Package Dimensions (L x W x H)
190.5 mm x 228.6 mm x 177.8 mm
Package Weight (Imperial)
28.0000 L
Package Weight (Metric)
12.4000 kg
dV/dT filter 80 amperes up to 600 volts open style 1000 feet

CD1X0080F1

dV/dT filter 80 amperes up to 600 volts open style 1000 feet
dV/dT filter 65 amperes up to 600 volts open style 1000 feet

CD1X0065F1

dV/dT filter 65 amperes up to 600 volts open style 1000 feet
dV/dT filter 54 amperes up to 600 volts open style 1000 feet

CD1X0054F1

dV/dT filter 54 amperes up to 600 volts open style 1000 feet
dV/dT filter 45 amperes up to 600 volts open style 1000 feet

CD1X0045F1

dV/dT filter 45 amperes up to 600 volts open style 1000 feet
dV/dT filter 35 amperes up to 600 volts open style 1000 feet

CD1X0035F1

dV/dT filter 35 amperes up to 600 volts open style 1000 feet
dV/dT filter 27 amperes up to 600 volts open style 1000 feet

CD1X0027F1

dV/dT filter 27 amperes up to 600 volts open style 1000 feet
dV/dT filter 22 amperes up to 600 volts open style 1000 feet

CD1X0022F1

dV/dT filter 22 amperes up to 600 volts open style 1000 feet
dV/dT filter 17 amperes up to 600 volts open style 1000 feet

CD1X0017F1

dV/dT filter 17 amperes up to 600 volts open style 1000 feet
dV/dT filter 12 amperes up to 600 volts open style 1000 feet

CD1X0012F1

dV/dT filter 12 amperes up to 600 volts open style 1000 feet
dV/dT filter 7 amperes up to 600 volts open style 1000 feet

CD1X0007F1

dV/dT filter 7 amperes up to 600 volts open style 1000 feet
dV/dT filter 4 amperes up to 600 volts open style 1000 feet

CD1X0004F1

dV/dT filter 4 amperes up to 600 volts open style 1000 feet
dV/dT filter 3 amperes up to 600 volts open style 1000 feet

CD1X0003F1

dV/dT filter 3 amperes up to 600 volts open style 1000 feet

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Immediately after receiving the HPS Centurion P Passive Harmonic Filter, inspect it for any transit damage and verify it against the shipping documents. Report any damages to the carrier.

  2. Mount the filter

    Securely mount the filter to a suitable location, ensuring at least 6 inches of clearance from walls and obstructions for ventilation. Use appropriate mounting screws and brackets as necessary.

  3. Connect the wiring

    Connect the input power supply to terminals A1, B1, and C1, and connect the load to terminals A2, B2, and C2. Ensure all connections are tight and follow local electrical codes.

  4. Ground the filter

    Properly ground the passive harmonic filter using the designated grounding location to ensure safe operation before energizing the unit.

  5. Commission the system

    Before connecting the filter to the system, use a power quality analyzer to measure baseline parameters such as total harmonic distortion and power factor. After connecting, repeat the measurements to assess performance.

  6. Calibrate and test

    Once the filter is energized, monitor its operation for any unusual noises or performance issues. Ensure that the output voltage and current are within specified limits as per the nameplate ratings.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.