Hammond Power CD1X0027F1 - dV/dT filter 27 amperes up to 600 volts open style 1000 feet
Hammond Power

CD1X0027F1

UPC: 803423189884


Documents & Media
BrochureInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Hammond Power Solutions (HPS) CD1X0027F1 dV/dT filter is a 27-ampere, 600-volt open-style device designed to mitigate voltage spikes in variable frequency drive (VFD) motor applications. It protects motors from insulation stress and premature failure when using long cable runs up to 1000 feet between the VFD and motor. The filter reduces dV/dT (rate of voltage rise) to comply with IEEE 519 standards, minimizing reflected wave transients that can damage motor windings. Ideal for industrial environments where extended motor cable lengths are required, this filter ensures reliable operation in HVAC, pump, fan, and conveyor systems. The open-style design allows for flexible mounting and integration into existing control panels or enclosures. Rated for continuous duty, the CD1X0027F1 supports 600V three-phase systems and is UL listed for safety compliance. Compatible with motors and VFDs operating at 27A and 600V, it is manufactured in France and carries the UNSPSC code 83101808.
  • The dV/dT filter combines an inductor and parallel resistor network to mitigate both high frequency components and voltage spikes between the VFD and motor.
  • The filter can mitigate the effects of reflected wave voltages greater than what a reactor alone can accomplish.
  • The filter provides protection to the motor by slowing down the rate of voltage increase and minimizes the damaging peak voltages that occur within the motor’s windings and along the length of cables feeding the motor.
  • Supports motor cable runs up to 1000 feet between VFD and motor
  • UL listed for safety compliance; manufactured in France
  • UL listed for safety compliance
  • Manufacturer: Hammond Power Solutions (HPS)
  • SKU: CD1X0027F1

Specifications

Application
Designed for applications with long cables between the VFD and the motor
Cooling
Natural Convection
Current Rating
27 A
Enclosure
Open Frame
Height
44 IN
Inverter Specification
Switching Frequency: 2kHz - 4kHz, Operating Frequency: up to 60Hz
Length
16 IN
Maximum Ambient Temperature
40C (suitable to 50C)
Minimum Ambient Temperature
-25C
Mounting
Wall/Ceiling/Floor Mount
Mounting Type
Open Style
Peak Voltage
at Motor: 150% of DC bus voltage
Poles
3
Poles
3PH
Series
CD1X
Standard
cUL
Voltage Rating
up to 600V
Voltage Rating
600 VAC
Voltage Rating
600 V
Weight
1000 lbs
Width
23 IN
Package Dimensions (L x W x H)
6 IN x 8 IN x 7.25 IN
Package Dimensions (L x W x H)
152.4 mm x 203.2 mm x 184.15 mm
Package Weight (Imperial)
14.0000 L
Package Weight (Metric)
6.2000 kg
dV/dT filter 22 amperes up to 600 volts open style 1000 feet

CD1X0022F1

dV/dT filter 22 amperes up to 600 volts open style 1000 feet
POE INJECTOR OUTDOOR LORA GTW

48290940

POE INJECTOR OUTDOOR LORA GTW

How to Install the HPS Centurion P Passive Harmonic Filter

This guide provides step-by-step instructions for the installation and initial setup of the HPS Centurion P Passive Harmonic Filter, ensuring safe and effective operation.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding wire

  1. Inspect the unit

    Examine the HPS Centurion P Passive Harmonic Filter for any transit damage and verify against the shipping documents. If any damage is found, do not energize the unit and contact HPS.

  2. Mount the filter

    Secure the passive harmonic filter to a suitable location using mounting screws. Ensure there is at least 6 inches of clearance around the unit for ventilation.

  3. Ground the filter

    Connect the designated main grounding location on the filter to a proper ground. Ensure all connections are tight and secure to prevent electric shock.

  4. Make electrical connections

    Connect the input terminals A1, B1, and C1 to the corresponding phases of the power supply. Connect output terminals A2, B2, and C2 to the load. Refer to the nameplate for specific wiring instructions.

  5. Verify connections

    Use a multimeter to check that all electrical connections are secure and that there are no shorts. Confirm that the power supply is off before proceeding.

  6. Energize the system

    Turn on the power supply to the HPS Centurion P Passive Harmonic Filter. Monitor for any unusual sounds or indicators of malfunction.

  7. Perform initial testing

    Use a power quality analyzer to measure total harmonic distortion and power factor before and after connecting the filter. Document the results for future reference.

Frequently Asked Questions about Hammond Power

What certifications and standards do Hammond Power products comply with?

Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.

What is Hammond Power's warranty policy?

Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.

What industries and applications are Hammond Power products used for?

Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.

What are the main product lines offered by Hammond Power?

Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.

What are the key features of Hammond Power products?

Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.

What environmental ratings do Hammond Power products have?

Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.

What technical support does Hammond Power offer?

Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.

What communication protocols do Hammond Power products support?

Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.

What accessories are available for Hammond Power products?

Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.

How are Hammond Power products typically installed?

Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.