Hammond Power C1FC15PE 600V Class Commercial Potted Single Phase Distribution Transformer, 600 PV, 120/240 SV…
UPC: 803423093518
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 0.15 kVA single-phase capacity for commercial/light industrial use
- 600V primary (600 PV) and 120/240V secondary (120/240 SV) voltages
- Potted construction for moisture resistance and vibration dampening
- Compact design for indoor installations in control circuits and lighting
- Manufactured in the USA
Specifications
Application | Shopping centers, schools, sports complexes, commercial, lighting, wastewater and light industrial loads. |
Connection Type | 600 PV, 120/240 SV |
Connection Type | 600V Primary, 120/240V Secondary |
Connection Type | 600 V Primary / 120/240 V Secondary |
Connection Type | Wiring |
Enclosure | NQ0-N3R - Indoor or Outdoor |
Frequency Rating | 60 HZ |
Height | 7.25 in |
Input Voltage | 600 V |
Length | 5.25 IN |
Material | Potted |
Mounting | Wall Mount |
Mounting Type | Potted |
Output Voltage | 120/240 V |
Phase | Single Phase |
Poles | 1P |
Poles | Single Phase |
Poles | Single-Phase |
Series | C1FC |
Series | C1F |
Special Features | Innovative potted design provides single screw access on a hinged cover to the wiring compartment for commercial indoor and outdoor applications |
Standard | csa, ul |
Type | Transformer > Distribution > Potted > Commercial > Single Phase |
Voltage Rating | 600 V |
Voltage Rating | 600V/120/240V |
Wattage | 0.15 KVA |
Width | 3.75 IN |
Winding | Aluminum Wound |
Package Dimensions (L x W x H) | 3.75 IN x 5.25 IN x 7.25 IN |
Package Dimensions (L x W x H) | 9.525 cm x 13.335 cm x 18.415 cm |
Package Weight (Imperial) | 7.100 L |
Package Weight (Metric) | 3.221 kg |
Frequently Asked Questions
What types of enclosures are available for these transformers?
The transformers come with a Type 3R enclosure. Type 4/12 enclosures are available with an optional gasket kit.
What is the warranty period for HPS Fortress encapsulated transformers?
All HPS standard catalog encapsulated transformers come with a 10-year limited warranty.
What are the available kVA ratings for single-phase transformers?
Single-phase transformers are available from 0.05 kVA up to 37.5 kVA.
What are the available kVA ratings for three-phase transformers?
Three-phase transformers are available from 2 kVA up to 75 kVA.
What is the purpose of the encapsulation in these transformers?
Encapsulation with silica sand and resin seals out moisture and contaminants, preventing corrosion and deterioration.
What approvals do these transformers have?
The transformers are UL Listed (file No. E50394) and CSA Certified (file No. LR3902).
What is the frequency range for HPS Fortress transformers?
The standard frequency is 60Hz. For some voltage groups, 50Hz is also standard.
Are conduit knockouts provided for installation?
Yes, conduit knockouts are provided for rear and side entry into the wiring compartment.
Can these transformers be wall-mounted?
Wall mounting is supported up to 25 kVA for single-phase units, with an optional bracket for 37.5 kVA. For three-phase units, wall mounting is supported up to 9 kVA, with optional brackets for 15 kVA, 30 kVA, and 45 kVA.
What is the standard shield feature on these transformers?
A standard shield is included on single-phase units from 750VA and up, and on all three-phase units.
Frequently Asked Questions about Hammond Power
What certifications and standards do Hammond Power products comply with?
Hammond Power products are certified to UL (Underwriters Laboratories) and CSA (Canadian Standards Association) standards in North America. Our products meet rigorous safety and performance requirements, with many items classified as UL Listed Products or Recognized Components. We also comply with international certifications including China Compulsory Certification (CCC), C-Tick for Australian EMC requirements, and ANCE for Mexico.
What is Hammond Power's warranty policy?
Hammond Power provides a standard one-year warranty on all products, covering defects in workmanship and materials. Products will be repaired or replaced free of charge if found defective upon factory inspection. The warranty does not cover damage from improper handling, incorrect application, or faulty installation.
What industries and applications are Hammond Power products used for?
Hammond Power products are engineered for critical industrial and commercial applications across multiple sectors, including petrochemical, mining, construction, renewable energy, e-mobility, power storage, and microgrids. Their comprehensive product range of dry-type transformers, power quality solutions, and magnetic components enables electrical distribution and electrification in diverse industrial environments worldwide.
What are the main product lines offered by Hammond Power?
Hammond Power Solutions offers a comprehensive range of dry-type and liquid-filled transformers for industrial and commercial applications. Their primary product lines include power transformers for renewable energy, e-mobility, data centers, microgrids, and industrial settings. The company provides both standard and custom-designed transformer solutions that are critical to electrical distribution networks across multiple industries.
What are the key features of Hammond Power products?
Hammond Power products feature advanced dry-type and liquid-filled transformers engineered for diverse industrial applications, with capabilities spanning renewable energy, e-mobility, data centers, microgrids, and industrial/commercial sectors. Key features include high-performance electrical steel laminations, windings available in copper or aluminum, advanced insulation systems (VPI or Cast Resin), Basic Impulse Level ranges from 10 kV to 250 kV, and custom design capabilities with over 3,000 unique transformer designs engineered annually.
What environmental ratings do Hammond Power products have?
Hammond Power offers industrial enclosures with comprehensive environmental ratings, including UL/cUL 508A ratings of Type 1, 2, 3, 4, 4X, 12, and 13. Their products meet IEC 60529 IP66 standards, providing robust protection against dust, water ingress, and harsh environmental conditions. Specific ratings vary by product series, with options ranging from indoor Type 1 enclosures to outdoor-rated Type 4X enclosures suitable for challenging industrial environments.
What technical support does Hammond Power offer?
Hammond Power Solutions provides comprehensive technical support through multiple channels. Customers can access technical resources via phone support in Canada, the United States, Mexico, and internationally, with toll-free numbers and regional contact points. Their technical team offers personalized assistance for custom design inquiries, helping customers find standard transformer and power solutions or develop specialized electrical products for various industrial applications.
What communication protocols do Hammond Power products support?
Hammond Power products support multiple industrial communication protocols, including Modbus RTU, PROFIBUS DP, PROFINET, EtherNet/IP, and CANopen. These protocols enable flexible connectivity across industrial automation platforms, supporting various network topologies and high-speed data transmission for comprehensive industrial control and monitoring applications.
What accessories are available for Hammond Power products?
Hammond Power offers a comprehensive range of accessories for industrial electrical components, including HME Series handles with key locking and padlocking options, door stop kits, light kit mounting brackets, and standard hardware like mounting screws and washers. These accessories are designed to enhance functionality and installation flexibility across their product lines.
How are Hammond Power products typically installed?
Hammond Power transformers are typically chassis-mounted using precise mounting hole centers and dimensions specific to each product series. Installation involves selecting the appropriate primary voltage configuration, securing the transformer to a mounting surface using the specified mounting holes, and connecting terminals according to the product's schematic. Most Hammond Power transformers feature multiple terminal options like solder or quick-connect terminals, allowing flexible and straightforward installation in industrial control and power distribution applications.