Federal Signal FB2PST-I-024C - Fireball Strobe Light, Limited In-Rush, UL and cUL, 24VDC, Clear
Federal Signal

FB2PST-I-024C

Alternate Item Number: fb2pst-i-fireball

UPC: 782979215875


Documents & Media
BrochureInstallation InstructionsLine DrawingSpecification SheetWarranty

Contact for Pricing

Overview

The Federal Signal FB2PST-I-024C Fireball Strobe Light offers reliable, high-visibility illumination for industrial, commercial, and safety-critical applications. This clear-lens strobe operates on 24VDC, providing energy-efficient signaling with a strong visual impact. Certified by UL and cUL, it meets stringent safety standards, making it suitable for emergency exit signage, fire alarm systems, and general high-visibility warning needs. The integrated Limited In-Rush feature protects internal circuitry from power surges, enhancing device longevity and ensuring consistent performance. Federal Signal's commitment to durable, high-performance lighting solutions means the FB2PST-I-024C is built to withstand harsh conditions. Its robust construction and precise engineering make it a dependable choice for warehouses, factories, and public buildings, improving safety and compliance. The clear lens ensures maximum light output for critical signaling. SKU: FB2PST-I-024C. UNSPSC: 39111706. Country of Origin: US.
  • Clear lens for maximum visibility
  • 24VDC operating voltage for energy efficiency
  • UL and cUL certified for safety compliance
  • Limited In-Rush feature protects circuitry
  • Durable construction for industrial environments

Specifications

-31 to 150
DEG F
0.7
A
0.70
A
1,000,000
CND
10,000
HR
24
VDC
5.25 H x 4.10 W x 4.10 D
IN
80
FLPM
Amperage
0.7 A
Amperage Rating
0.7 AMP
Application
Indoor/Outdoor
Average Life
10,000 HR
Brand Name
Federal Signal
Candela Power
300
Candela Power Peak
1,000,000
Candle Power
1,000,000 CND
Color
Clear
Diameter
4.1 in (104.1 mm)
Environmental Conditions
-31 to 150 DEG F
Flashes Per Minute
80 FLPM
Lens Color
Clear
Lens Style
Fresnel
Light Source
Strobe Tube
Material
Glass
Material
Clear Glass
Material
Zinc/Polycarbonate
Model
FB2PST-I
Mounting
1/2-Inch NPT Pipe/Surface
Mounting
1/2-Inch NPT Pipe,Surface
NEMA Rating
Type 4X, IP66, IP69K Enclosure
Operating Temperature
-31D to +150DF (-35D to +66DC)
Power Peak
1000000
Series
Fireball
Series
Fireball Strobe Light
Shape
Cylindrical
Size
5.25 H x 4.10 W x 4.10 D IN
Special Features
Voltage In-Rush Limiting PCB Design
Standard
UL Listed/cUL Listed/CSA Certified
Standard
CSA,UL,cUL
Style
Strobe
Sub Brand
Fireball
Type
Strobe Warning Light
Voltage Rating
24 Vdc
Package Dimensions (L x W x H)
4.75 IN x 4.75 IN x 7 IN
Package Dimensions (L x W x H)
12.065 cm x 12.065 cm x 17.78 cm
Package Weight (Imperial)
2.120 L
Package Weight (Metric)
0.962 kg
Global Series Strobe Light, Hazardous Location, UL and cUL CID2, Zone Listed, 24VDC, Ex de Surface Mount, 21J, Clear

G-STR-024-E-C

Global Series Strobe Light, Hazardous Location, UL and cUL CID2, Zone Listed, 24VDC, Ex de Surface Mount, 21J, Clear
PA X 1-05 24 DC CL GL/MED

23311801001

PA X 1-05 24 DC CL GL/MED
KSB-113C Light Element Xenon tube Clear Flashing light

KSB-113C

KSB-113C Light Element Xenon tube Clear Flashing light
Horn/Strobe 120VAC White

TA880-N5

Horn/Strobe 120VAC White

Frequently Asked Questions

What is the operating voltage for Fireball strobes?

Federal Signal Fireball strobes are available in 24VDC.

What is the enclosure rating for Fireball strobes?

Fireball strobes have a Type 4X, IP66 enclosure rating and are IP69K compliant.

What are the mounting options for Fireball strobes?

Fireball strobes feature an integrated 1/2-inch NPT pipe and surface mount.

What is the expected life of the strobe tube?

The strobe tube in Fireball strobes has a 10,000-hour lifespan.

What are the candela ratings for Fireball strobes?

Fireball strobes have a peak candela of 1,000,000 and an effective candela of 300.

Do Fireball strobes offer corrosion resistance?

Yes, Fireball strobes feature a black epoxy coating for superior corrosion resistance.

Is the FB24STHI-024C-CN Fireball strobe fire listed?

The FB24STHI-024C is UL Fire Listed, and the FB24STHI-024C-CN is ULC Canadian Fire Listed.

What dome color is available for the FB24STHI strobe?

The FB24STHI model comes with a clear dome.

How are Fireball strobes wired for FACP supervision?

Fireball strobes include four wires and a supervisory diode for proper FACP supervision.

Are Fireball strobes protected against in-rush current?

Yes, Fireball strobes are in-rush protected.

How to Install the FB2PST-I-024C Fireball Light

This guide provides step-by-step instructions for installing and configuring the FB2PST-I-024C Fireball light, ensuring proper mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Unpack and Inspect the Unit

    Carefully unpack the FB2PST-I-024C unit and inspect it for any visible damage that may have occurred during transit. If damaged, do not proceed with installation and file a claim with the carrier.

  2. Mount the Light

    Using the gasket as a template, mark three mounting holes and one central hole on the mounting surface. Drill three 3/16" (4.8 mm) holes for the screws and one 1" (25.4 mm) hole for the wiring. Secure the light to the surface using the provided #8-32 screws.

  3. Make Electrical Connections

    Ensure power is off before connecting. For the FB2PST-I (24VDC), connect the red (+) lead to the positive terminal of the power source and the black (-) lead to the negative terminal. Verify connections are secure and correct polarity is observed.

  4. Test the Light

    After completing the installation and connections, restore power and test the light to ensure it operates correctly. If it does not function, recheck all connections and ensure power is supplied.

  5. Finalize Installation

    Once testing is complete and the light is operational, ensure all screws are tightened properly. Provide a copy of the instruction sheet to all operating personnel and establish a routine check procedure for the light's integrity and operation.

Frequently Asked Questions about Federal Signal

What certifications and standards do Federal Signal products comply with?

Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.

What is Federal Signal's warranty policy?

Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.

What industries and applications are Federal Signal products used for?

Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.

What technical support does Federal Signal offer?

Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.

What are the main product lines offered by Federal Signal?

Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.

What are the key features of Federal Signal products?

Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.

What environmental ratings do Federal Signal products have?

Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.

What accessories are available for Federal Signal products?

Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.

What communication protocols do Federal Signal products support?

Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.

How are Federal Signal products typically installed?

Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.