- 30W amplified output for clear audio in hazardous areas
- Explosion-proof housing meets UL/cUL CID1 and ULC Fire Listed standards
- 24VDC operation for compatibility with industrial power systems
- Supervised design for continuous monitoring and fault detection
- Gray powder-coated steel housing resists corrosion and moisture
Specifications
-40 to 150 | DEG F |
1.3 | A |
100 | DB |
112 | dBa |
122 | dBa |
18.8 H x 16.7 W x 19.5 D | IN |
24 | VDC |
24 Vdc | V |
30 | W |
Amperage | 1.3 A |
Application | Indoor/Outdoor |
Brand Name | Federal Signal |
Color | Gray |
dBa at 10ft | 112 dBa |
dBa at 1M | 122 dBa |
Dimensions | 18.8 H x 16.7 W x 19.5 D IN |
Enclosure | Type 4X |
Loudness | 100 DB |
Material | Cast Aluminum Housing/Spun Aluminum Projector |
Mounting | Surface |
Operating Current | 1.3 AMP |
Operating Temperature | -40 to 150 DEG F |
Operating Voltage | 24VDC |
Special Features | Produces Tones Or Voice Messages |
Standard | UL Listed/cUL Listed/ULC Fire Listed/CSFM Approved |
Sub Brand | SelecTone |
Type | Audible Signals |
Type | Explosion-Proof Amplified Speaker |
Voltage Rating | 24 Vdc |
Wattage | 30 W |
Package Dimensions (L x W x H) | 23.31 IN x 23.31 IN x 26 IN |
Package Dimensions (L x W x H) | 59.2074 cm x 59.2074 cm x 66.04 cm |
Package Weight (Imperial) | 32.400 L |
Package Weight (Metric) | 14.697 kg |

304GCX-024-CN
SelecTone 15W Amplified Speaker, Hazardous Location, Supervised, UL and cUL, ULC Fire Listed, 24VDC, Gray
314GCX-024-CN
SelecTone 30W Amplified Speaker, Explosion-Proof, Supervised, UL and cUL CID1, ULC Fire Listed, 24VDC, GrayFrequently Asked Questions
What certifications does the 300X-120-240 hold?
The 300X-120-240 is UL and cUL CID1 certified, indicating its suitability for hazardous locations.
What type of speaker is the 300X-120-240?
The 300X-120-240 is a SelecTone 15W Amplified Speaker. It is designed to be explosion-proof.
What are the power requirements for the 300X-120-240?
The 300X-120-240 SelecTone speaker operates on 120-240VAC.
Is the 300X-120-240 suitable for hazardous locations?
Yes, the 300X-120-240 is an Explosion-Proof speaker, UL and cUL CID1 certified for hazardous locations.
What environments is the 300X-120-240 designed for?
The 300X-120-240 is designed to withstand a long life in harsh, industrial environments.
Does a single device failure affect the SelecTone system?
No, if one device fails in a SelecTone system, the other devices will continue to operate.
Can the 300X-120-240 be used as a stand-alone speaker?
Yes, each SelecTone speaker and amplifier, including the 300X-120-240, can be used for stand-alone signaling applications.
What types of notifications can SelecTone speakers provide?
SelecTone speakers can provide multiple tones, voice, live PA notifications, and pre-recorded messages.
How can SelecTone speakers be activated?
SelecTone speakers are capable of both live and remote activation.
What is the purpose of the Connector Card?
Connector Cards are installed in each powered loudspeaker to provide communication with the SelecTone Command Unit. They can also add speakers to existing public address systems.
How to Install the 314X-024-CN Explosion-Proof Amplified Speaker
Installation guide for mounting and wiring the 314X-024-CN explosion-proof amplified speaker. Ensure proper safety precautions are followed.
Estimated time: 45m
Tools needed:
Screwdriver, Drill, Wrench
Supplies needed:
Mounting bolts, Lockwashers, Hex nuts, Tone Card (sold separately), Connector Card (sold separately)
- Unpack and Inspect Speaker
Carefully unpack the 314X-024-CN speaker and inspect it for any damage that may have occurred during transit. If damaged, file a claim with the carrier immediately and do not attempt installation.
- Prepare for Mounting
Remove the two 1/2"-13 hex-head bolts, flat washers, and lockwashers securing the mounting bracket to the speaker. Disconnect the lanyard from the mounting bracket at the cotter ring.
- Select Mounting Location
Choose a mounting location on a flat surface capable of supporting the speaker's weight. Ensure the front of the speaker is clear of obstructions for optimal sound distribution. Mount the speaker so the projector is pointed horizontally or slightly downward to prevent water or debris accumulation.
- Mark and Drill Mounting Holes
Use the mounting bracket as a template to scribe drill position marks on the mounting surface. Drill 1/2" diameter holes at the scribed marks, ensuring both sides of the surface are clear before drilling.
- Secure Mounting Bracket
Attach the mounting bracket to the surface using 1/2" diameter hex-head bolts, lockwashers, and hex nuts. Ensure the bracket is securely fastened.
- Attach Speaker to Bracket
Reattach the speaker to the mounting bracket using the two 1/2"-13 hex-head bolts, flat washers, and lockwashers. Position the speaker for the required sound coverage and tighten the bolts securely.
- Secure Lanyard
Reattach the lanyard to the cotter ring and mounting bracket. Verify that it is securely attached to both the cover and the mounting bracket.
- Route Wiring
Route wires through the 1/2" NPT threaded openings into the SelecTone unit in accordance with national and local electrical and fire codes. Wire size depends on operating current and distance from the power source. Do not connect wires when power is on.
- Install Tone or Connector Card
Loosen and remove the threaded cover by turning it counter-clockwise. Plug the tone card (UTM) or connector card (purchased separately) into the socket. Rotate the card retainer into position to hold the card in place. Ensure sealing surfaces are not damaged.
- Connect Power Leads
Connect the positive (+) power-source lead to the terminal block labeled L+. Connect the negative (–) power-source lead to the terminal block labeled N–. Connect additional leads to the next speaker or end-of-line device as required. Ensure independent conductors are terminated separately for electrical supervision.
- Connect Audio Leads (if applicable)
If using a connector card for voice messages, connect one pair of white leads to the audio output of the fire alarm panel and the other pair to the next speaker or a contact on the power supervision relay and an end-of-line device. Consult the authority having jurisdiction for proper EOL resistor and supervision relay application.
- Reinstall Housing Cover
Carefully reinstall the housing cover and tighten it until the cover flange makes contact with the housing. Tighten the set screw on the cover to secure it. Verify that the mounting bolts are securely tightened. The housing cover must be kept tight while circuits are energized to reduce explosion risk.
- Test Speaker Operation
After installation, test the system to verify each speaker operates satisfactorily. If the volume is too loud, remove the cover, insert a screwdriver into the volume control, and turn counter-clockwise to decrease loudness. Reinstall the housing cover.
Frequently Asked Questions about Federal Signal
What certifications and standards do Federal Signal products comply with?
Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.
What is Federal Signal's warranty policy?
Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.
What industries and applications are Federal Signal products used for?
Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.
What technical support does Federal Signal offer?
Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.
What are the main product lines offered by Federal Signal?
Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.
What are the key features of Federal Signal products?
Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.
What environmental ratings do Federal Signal products have?
Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.
What accessories are available for Federal Signal products?
Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.
What communication protocols do Federal Signal products support?
Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.
How are Federal Signal products typically installed?
Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.