Authorized Federal Signal Distributor
Federal Signal 304GCX-024-CN-R - SelecTone 15W Amplified Speaker, Hazardous Location, Supervised, UL and cUL, ULC Fire Listed, 24VDC, Red

Federal Signal 304GCX-024-CN-R SelecTone 15W Amplified Speaker, Hazardous Location, Supervised, UL and cUL, ULC Fire…

Alternate Item Number: 304gcx-314gcx

UPC: 782979233428


Documents & Media
BrochureInstallation InstructionsLine DrawingSpecification SheetWarranty

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Federal Signal 304GCX-024-CN-R SelecTone 15W Amplified Speaker is a critical audio signaling solution designed for hazardous location environments. This unit operates on a 24VDC power supply, delivering a robust 15W of amplified sound to ensure clear and audible alerts in high-noise industrial settings. The speaker features a striking red finish for rapid visibility and identification in critical applications. Certified to UL and cUL standards and ULC Fire Listed, the 304GCX-024-CN-R meets stringent safety requirements for use in potentially explosive atmospheres. Its supervised operation designation provides an essential layer of system integrity, enabling remote monitoring to confirm operational readiness. The compact design allows for easy installation on existing infrastructure, reducing deployment time and costs. The 15W amplification guarantees high-volume output for personnel safety and operational efficiency. Federal Signal’s SelecTone series is built for durability, with construction designed to withstand harsh industrial conditions while maintaining consistent performance over extended periods.
  • 15W amplified output for clear, high-volume alerts in noisy environments
  • 24VDC operation for compatibility with industrial power systems
  • Red finish for high visibility and rapid identification
  • Supervised operation for remote monitoring and system integrity
  • UL/cUL and ULC Fire Listed for hazardous location compliance
  • High-visibility red finish

Specifications

-40 to 150
DEG F
.07
AMP
0.7
A
108
dBa
118
dBa
12.4 H x 7.9 W x 8.5 D
IN
15
W
24
VDC
24 Vdc
V
95
DB
Amperage
0.7 A
Application
Indoor/Outdoor
Brand Name
Federal Signal
Color
Red
dBa at 10ft
108 dBa
dBa at 1M
118 dBa
Dimensions
12.4 H x 7.9 W x 8.5 D IN
Enclosure
Type 4X, IP66, IP69K
Loudness
95 DB
Material
Cast Aluminum Housing/Spun Aluminum Projector
Mounting
Surface
Operating Current
.07 AMP
Operating Temperature
-40 to 150 DEG F
Operating Voltage
24VDC
Series
SelecTone
Special Features
Digital Signal Amplification
Standard
UL Listed/cUL Listed/ULC Canadian Fire Listed/CSFM Approved
Sub Brand
SelecTone
Type
Audible Signals
Type
Hazardous Location Amplified Speaker
Voltage Rating
24 Vdc
Wattage
15 W
Package Dimensions (L x W x H)
10 IN x 10 IN x 13.5 IN
Package Dimensions (L x W x H)
25.4 cm x 25.4 cm x 34.29 cm
Package Weight (Imperial)
5.700 L
Package Weight (Metric)
2.586 kg
Amplified Speaker, 15W, Supervised, Hazardous Location, UL and cUL CID2, UL Fire, 24VDC, Red

ASHH-024

Amplified Speaker, 15W, Supervised, Hazardous Location, UL and cUL CID2, UL Fire, 24VDC, Red
PA X 10-10 12 DC RO

23361855000

PA X 10-10 12 DC RO
Warning Siren 120VAC/DC Weatherproof

TA315-1N5

Warning Siren 120VAC/DC Weatherproof
Hazardous Area Powered Loudspeaker, 8 Watt, Multi-Voltage, Atex, EExdIIB - 104 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.

ES1-114-74

Hazardous Area Powered Loudspeaker, 8 Watt, Multi-Voltage, Atex, EExdIIB - 104 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.
Non-Metallic Zone 1 Loudspeaker, Gas Group IIB, 8 Ohm - Corrosion-resistant Anti-Static GRP (Glass-Reinforced Polyester) design. U-Mounting bracket included, optional swivel mount bracket available. Stainless-Steel Hardware. CE Compliant. ATEX and IECEx Certified for Zone 1 Gas Groups IIB and IIC. IP66 rated.

P-LS2B-8

Non-Metallic Zone 1 Loudspeaker, Gas Group IIB, 8 Ohm - Corrosion-resistant Anti-Static GRP (Glass-Reinforced Polyester) design. U-Mounting bracket included, optional swivel mount bracket available. Stainless-Steel Hardware. CE Compliant. ATEX and IECEx Certified for Zone 1 Gas Groups IIB and IIC. IP66 rated.
Hazardous Area Powered Loudspeaker, 8 Watt, Multi-Voltage, Atex, EExdIIC - 104 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.

ES1-114-24

Hazardous Area Powered Loudspeaker, 8 Watt, Multi-Voltage, Atex, EExdIIC - 104 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.
Hazardous Area Powered Loudspeaker, 15 Watt, Multi-Voltage, Atex, EExdIIC - 107 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.

ES1-112-24

Hazardous Area Powered Loudspeaker, 15 Watt, Multi-Voltage, Atex, EExdIIC - 107 dBa at 1 meter. Remote tone selection. Dual cable entries. 15 tones on-board sounder. Integrated DC and AC voltages. Short horn version (8W). Approved for Zone 1 IIB and IIC. IP66 or IP67 enclosure. ES4-120 and ES5-120 versions are IECEx, INMETRO and EAC only. ATEX, IEXCx, and CE Rated.
Loudspeaker, Powered, 25 Watt, 24VDC, ATEX, EExdIIB

ES5-120-73EB

Loudspeaker, Powered, 25 Watt, 24VDC, ATEX, EExdIIB

Frequently Asked Questions

What type of speaker is the 300X-120-240?

The 300X-120-240 is a SelecTone 15W Amplified Speaker. It is designed to be explosion-proof.

What are the power requirements for the 300X-120-240?

The 300X-120-240 SelecTone speaker operates on 120-240VAC.

Is the 300X-120-240 suitable for hazardous locations?

Yes, the 300X-120-240 is an Explosion-Proof speaker, UL and cUL CID1 certified for hazardous locations.

What certifications does the 300X-120-240 hold?

The 300X-120-240 is UL and cUL CID1 certified, indicating its suitability for hazardous locations.

What environments is the 300X-120-240 designed for?

The 300X-120-240 is designed to withstand a long life in harsh, industrial environments.

Does a single device failure affect the SelecTone system?

No, if one device fails in a SelecTone system, the other devices will continue to operate.

Can the 300X-120-240 be used as a stand-alone speaker?

Yes, each SelecTone speaker and amplifier, including the 300X-120-240, can be used for stand-alone signaling applications.

What types of notifications can SelecTone speakers provide?

SelecTone speakers can provide multiple tones, voice, live PA notifications, and pre-recorded messages.

How can SelecTone speakers be activated?

SelecTone speakers are capable of both live and remote activation.

What is the purpose of the Connector Card?

Connector Cards are installed in each powered loudspeaker to provide communication with the SelecTone Command Unit. They can also add speakers to existing public address systems.

How to Install the 304GCX-024-CN-R SelecTone Amplified Speaker

Installation guide for mounting and wiring the 304GCX-024-CN-R SelecTone amplified speaker. Ensure proper sound distribution and electrical connections for safe operation.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Drill, Wrench (if mounting on metal surface)

Supplies needed:

Mounting screws (#10 x 1" wood screws or #10 screws with lockwashers and nuts for metal surfaces), Conduit fittings, Wire connectors, 1/2" conduit plug (if needed)

  1. Unpack and Inspect

    Carefully unpack the 304GCX-024-CN-R SelecTone amplified speaker and inspect it for any signs of damage that may have occurred during transit. If damage is found, file a claim with the carrier immediately.

  2. Select Mounting Location and Orientation

    Choose a mounting location that allows for optimal sound distribution. Mount the unit so the speaker projector is pointed horizontally or slightly downward to prevent water or debris accumulation. Ensure the front of the speaker is clear of obstructions. For Models 304GCX and 314GCX, do not use the 7/8” knockout for concealed conduit mounting to maintain hazardous location rating.

  3. Mount the Speaker

    For flat surface mounting: Remove and retain the cover screws, then remove the cover. Place the rear of the housing against the mounting surface and use the mounting holes as a template to mark drill positions. Secure the unit using appropriate screws (#10 x 1" wood screws for wood, or #10 screws with lockwashers and nuts for metal). For concealed conduit mounting (Models 304GC and 314GC only): Remove the cover, remove the 7/8" knockout, install conduit connection, and then proceed with marking and securing the unit as described for flat surface mounting. Install 1/2” conduit plugs in any unused bottom entryways.

  4. Reposition Speaker Projector (if necessary)

    If needed, adjust the speaker projector for desired sound coverage. Loosen the collar nut, move the projector to the desired position, and then tighten the collar nut.

  5. Make Electrical Connections

    Ensure all power circuits are de-energized before making connections. Route wires through the 1/2" threaded openings in accordance with national and local electrical codes. Use 12 to 18 AWG wire and strip no more than 0.25 inch of insulation. Connect the positive (+) and negative (-) power leads to the appropriate terminals on the connector plug, ensuring each wire of the same polarity is terminated independently for electrical supervision. Plug the connector into the receptacle on the printed circuit board.

  6. Install Tone Card or Speaker Connector Card

    If using a tone card, plug the desired tone card into the provided socket. If using a speaker connector card (e.g., AM25CK, AM70CK), route the audio signal leads and connect them to the audio output of the fire alarm panel and the next unit or end-of-line device as per the connector card's manual. Plug the connector card into its socket.

  7. Reinstall Housing Cover

    Ensure the neoprene rubber cover gasket is properly seated in the housing groove. Reinstall the housing cover and ensure it is tightly secured, especially for Models 304GCX and 314GCX, to maintain explosion hazard suitability.

  8. Test the System and Adjust Volume

    After installation, test the system to verify satisfactory operation. If the volume is too loud, remove the housing cover and use a slotted screwdriver to adjust the internal volume control to the desired loudness. Reinstall the housing cover securely.

  9. Establish Periodic Testing and Documentation

    Establish a program for periodic testing of the device in accordance with NFPA 72, local fire codes, and the authority having jurisdiction. Provide a copy of these installation instructions to all personnel responsible for operation, testing, and maintenance.

Frequently Asked Questions about Federal Signal

What certifications and standards do Federal Signal products comply with?

Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.

What is Federal Signal's warranty policy?

Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.

What industries and applications are Federal Signal products used for?

Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.

What technical support does Federal Signal offer?

Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.

What are the main product lines offered by Federal Signal?

Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.

What are the key features of Federal Signal products?

Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.

What environmental ratings do Federal Signal products have?

Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.

What accessories are available for Federal Signal products?

Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.

What communication protocols do Federal Signal products support?

Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.

How are Federal Signal products typically installed?

Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.