Overview

The Federal Signal 191XL-120-240G is a rugged, high-performance LED pipe mount light designed for use in hazardous location environments. Certified to UL and cUL CID2 standards, this fixture meets the strict safety requirements of industrial settings where explosive atmospheres may be present. Its wide voltage rating of 120-240 VAC allows seamless integration into a variety of power systems, while the green LED color provides a clear, high-visibility indication that is easily distinguished from other lighting signals. The pipe mount design ensures a secure, flush installation on existing piping infrastructure, reducing the need for additional mounting hardware and simplifying maintenance. Equipped with a default flashing mode, the light enhances situational awareness during emergency situations or when a visual warning is required. Whether used in chemical processing plants, oil and gas facilities, or any other hazardous location, the 191XL-120-240G delivers reliable illumination, superior durability, and compliance with industry safety standards. Choose Federal Signal for a lighting solution that protects personnel and equipment while maintaining operational efficiency.
  • Wide voltage range 120-240 VAC
  • Green LED color for high visibility
  • Pipe mount design for easy installation
  • UL and cUL CID2 certified for hazardous locations
  • Default flashing mode for enhanced safety

Specifications

-58 to 150
DEG F
0.21-0.13
A
0.21/0.13
A
120-240
VAC
120-240VAC
V
200
CND
50,000
HR
60
FLPM
9.25 H x 5.5 W x 5.5 D
IN
Amperage
0.21/0.13 A
Amperage Rating
0.21-0.13 AMP
Application
Indoor/Outdoor
Average Life
50,000 HR
Brand Name
Federal Signal
Candela Power
200
Candle Power
200 CND
Color
Green
Diameter
5.5 in (137.7 mm)
Environmental Conditions
-58 to 150 DEG F
Flashes Per Minute
60 FLPM
Flashing Pattern
1x Flash/Steady
Lens Color
Green
Light Source
LED
Material
Aluminum/Glass
Model
191XL
Mounting
3/4-Inch NPT Pipe
NEMA Rating
Type 4X, IP66, IP69K Enclosure
Operating Temperature
-58D to +150DF (-50D to +66DC)
Shape
Cylindrical
Size
9.25 H x 5.5 W x 5.5 D IN
Special Features
Increased Shock and Vibration Resistance
Standard
Marine,NSF,UL,cUL
Standard
UL Listed/cUL Listed/Marine Listed
Style
Flashing
Type
Hazardous Location, Division Listed, LED Warning Light
Voltage Rating
120-240 VAC
Package Dimensions (L x W x H)
7 IN x 10.5 IN x 7.25 IN
Package Dimensions (L x W x H)
17.78 cm x 26.67 cm x 18.415 cm
Package Weight (Imperial)
4.250 L
Package Weight (Metric)
1.928 kg
LED Light, Hazardous Location, UL and cUL CID2, Zone Listed, Pipe Mount, 120-240VAC, Green, Default Flashing

191XL-CN-120-240G

LED Light, Hazardous Location, UL and cUL CID2, Zone Listed, Pipe Mount, 120-240VAC, Green, Default Flashing
QUADRO LED HI 90-253 AC GN

21108646000

QUADRO LED HI 90-253 AC GN
KL70-306G Light Element LED Green Blinking light

KL70-306G

KL70-306G Light Element LED Green Blinking light
Horn/Strobe 120VAC White

TA880-N5

Horn/Strobe 120VAC White
StreamLine LED Light, Low Profile, UL and cUL, 120VAC, NPT Pipe Mount, Red

LP3PL-120R

StreamLine LED Light, Low Profile, UL and cUL, 120VAC, NPT Pipe Mount, Red
Electraray LED Light, Hazardous Location, UL and cUL CID2, 120-240VAC, Amber, Default Flashing

225XL-120-240A

Electraray LED Light, Hazardous Location, UL and cUL CID2, 120-240VAC, Amber, Default Flashing
StreamLine LED Light, Low Profile, UL and cUL, 120VAC, T-Mount, Red

LP3TL-120R

StreamLine LED Light, Low Profile, UL and cUL, 120VAC, T-Mount, Red
StreamLine LED Light, Low Profile, UL and cUL, 120VAC, NPT Pipe Mount, Green

LP3PL-120G

StreamLine LED Light, Low Profile, UL and cUL, 120VAC, NPT Pipe Mount, Green

Frequently Asked Questions

How does IP69K protection compare to NEMA Type 4?

IP69K protects from close-range, powerful, high-temperature water jets and is dust-tight, unlike NEMA Type 4 which involves high volume, low pressure, and long-distance water.

What is the benefit of using IP69K rated products?

IP69K products help reduce product failures due to water/dust ingress, thereby increasing productivity and decreasing production downtime in harsh environments.

What type of product is the Federal Signal 191XL?

The Federal Signal 191XL is classified as a Hazardous Location LED Light.

What is the IP69K ingress protection rating?

IP69K is the highest standard on the Ingress Protection (IP) rating scale, designed for products regularly exposed to high-pressure and high-temperature washdowns.

What testing conditions define the IP69K rating?

IP69K testing involves high-pressure steam jet cleaning at 1160–1450 psi, 176°F (80°C), sprayed from 4 angles at 4–6 inches, with no dust ingress.

What environments are suitable for IP69K rated products?

IP69K products are ideal for applications in Food and Beverage, Wastewater, Pharmaceutical, Marine, Medical Facilities, and Medical Equipment Manufacturing.

What certifications do Federal Signal products typically hold?

Federal Signal products are designed to meet or exceed UL, CSA, CSFM, IECEx, and other global certifications, and the company is ISO 9001 Certified.

How to Install the 191XL Series LED Beacon

This guide provides step-by-step instructions for installing and wiring the 191XL Series LED Beacon in hazardous locations.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Conductive sealant

  1. Unpack and Inspect the Beacon

    Carefully unpack the beacon and inspect it for any damage that may have occurred during transit. Do not proceed with installation if the beacon is damaged.

  2. Mount the Beacon

    Choose a suitable location for the beacon. For pipe mounting, ensure the mating threads are clean, apply conductive sealant to the conduit threads, and secure the beacon to a 3/4" pipe using the set screw. For surface mounting, use the mounting base as a template to mark and drill two 9/32 inch holes, then secure the beacon with the supplied hardware.

  3. Wiring the Beacon

    Ensure power is off before connecting wires. For 120-240 Vac models, connect the black lead to the hot side and the white lead to the neutral side of the power source. For 24 Vac/dc models, connect the red lead to the positive side and the black lead to the negative side. If applicable, connect the green/yellow lead to earth ground.

  4. Reconnect Power and Test

    After completing the wiring, ensure all connections are secure and the beacon is properly closed. Reconnect power to the beacon and test its operation to ensure it is functioning correctly.

  5. Calibrate the Beacon

    If necessary, change the beacon from Flash Mode to Steady Mode by disconnecting power, removing the dome assembly, and adjusting the jumper on the printed circuit board as per the instructions. Reassemble and test the beacon again.

Frequently Asked Questions about Federal Signal

What certifications and standards do Federal Signal products comply with?

Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.

What is Federal Signal's warranty policy?

Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.

What industries and applications are Federal Signal products used for?

Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.

What technical support does Federal Signal offer?

Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.

What are the main product lines offered by Federal Signal?

Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.

What are the key features of Federal Signal products?

Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.

What environmental ratings do Federal Signal products have?

Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.

What accessories are available for Federal Signal products?

Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.

What communication protocols do Federal Signal products support?

Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.

How are Federal Signal products typically installed?

Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.