Authorized Federal Signal Distributor
Federal Signal 191XL-120-240A - LED Light, Hazardous Location, UL and cUL CID2, Pipe Mount, 120-240VAC, Amber, Default Flashing
Federal Signal

191XL-120-240A

Alternate Item Number: 191xl-led

UPC: 782979224518


Documents & Media
BrochureInstallation InstructionsLine DrawingSpecification SheetWarranty

Contact for Pricing

Overview

The **Federal Signal 191XL-120-240A** is a high-performance, UL and cUL CID2 certified LED hazard light engineered for demanding hazardous location environments. Designed to deliver uncompromising visibility and durability, this pipe-mountable warning light combines advanced LED technology with robust construction to ensure reliable operation in the most challenging industrial settings. With a voltage rating of 120-240 VAC, the 191XL-120-240A is compatible with standard industrial power systems worldwide, eliminating the need for complex voltage conversions or additional power supplies. Its amber illumination provides a universally recognized warning signal, enhancing safety protocols in high-risk areas where personnel and equipment require clear, immediate visual alerts. This industrial-grade hazard light is part of Federal Signal’s renowned **191XL Series**, a trusted line of signaling devices favored by safety professionals in oil and gas, chemical processing, mining, and manufacturing industries. The **CID2 certification** ensures compliance with the strictest hazardous location safety standards, including protection against dust, fibers, and explosive atmospheres, making it ideal for use in Class I, Division 2 and Class II, Division 2 environments. The **pipe mount design** allows for quick and secure installation on existing piping, structural beams, or dedicated mounting brackets, reducing downtime and simplifying retrofits in both new construction and legacy systems. Federal Signal’s **LED technology** delivers superior energy efficiency compared to traditional incandescent or halogen alternatives, reducing power consumption by up to 80% while maintaining high-intensity output. The **default flashing mode** ensures immediate visibility, even in low-light conditions or areas with high ambient noise, where auditory signals may be less effective. This feature is particularly valuable in refineries, chemical plants, and offshore platforms, where rapid hazard recognition can prevent accidents and mitigate operational risks. Installation is straightforward, requiring minimal tools and no specialized training. The **weatherproof and corrosion-resistant housing** is constructed from durable materials to withstand extreme temperatures, humidity, and chemical exposure, ensuring long-term reliability. Federal Signal’s commitment to quality is underscored by their **rigorous testing protocols**, which include vibration resistance, impact testing, and extended operational life cycles to guarantee performance in the harshest conditions. For safety managers and facility engineers, the **191XL-120-240A** represents a cost-effective solution that reduces maintenance overhead while enhancing workplace safety. Its compatibility with existing infrastructure, combined with Federal Signal’s reputation for innovation and reliability, makes it a preferred choice for facilities prioritizing both compliance and operational efficiency. Whether deployed as part of a comprehensive safety system or as a standalone warning device, this LED hazard light delivers the performance and durability required to protect personnel and assets in hazardous locations.
  • UL and cUL CID2 certified for hazardous locations (Class I, II, Division 2)
  • 120-240 VAC voltage range for global industrial compatibility
  • Amber LED illumination with default flashing mode for high visibility
  • Pipe mount design for quick, secure installation on existing structures
  • Energy-efficient LED technology with superior durability and low maintenance

Specifications

-58 to 150
DEG F
0.21-0.13
A
0.21/0.13
A
120-240
VAC
120-240VAC
V
200
CND
50,000
HR
60
FLPM
9.25 H x 5.5 W x 5.5 D
IN
Amperage
0.21/0.13 A
Amperage Rating
0.21-0.13 AMP
Application
Indoor/Outdoor
Average Life
50,000 HR
Brand Name
Federal Signal
Candela Power
200
Candle Power
200 CND
Color
Amber
Diameter
5.5 in (137.7 mm)
Environmental Conditions
-58 to 150 DEG F
Flashes Per Minute
60 FLPM
Flashing Pattern
1x Flash/Steady
Lens Color
Amber
Light Source
LED
Material
Aluminum/Glass
Model
191XL
Mounting
3/4-Inch NPT Pipe
NEMA Rating
Type 4X, IP66, IP69K Enclosure
Operating Temperature
-58D to +150DF (-50D to +66DC)
Shape
Cylindrical
Size
9.25 H x 5.5 W x 5.5 D IN
Special Features
Increased Shock and Vibration Resistance
Standard
Marine,NSF,UL,cUL
Standard
UL Listed/cUL Listed/Marine Listed
Style
Flashing
Type
Hazardous Location, Division Listed, LED Warning Light
Voltage Rating
120-240 VAC
Package Dimensions (L x W x H)
7 IN x 10.5 IN x 7.25 IN
Package Dimensions (L x W x H)
17.78 cm x 26.67 cm x 18.415 cm
Package Weight (Imperial)
4.250 L
Package Weight (Metric)
1.928 kg
LED Light, Hazardous Location, UL and cUL CID2, Zone Listed, Pipe Mount, 120-240VAC, Amber, Default Flashing

191XL-CN-120-240A

LED Light, Hazardous Location, UL and cUL CID2, Zone Listed, Pipe Mount, 120-240VAC, Amber, Default Flashing
BExBG 05-E 230V AC amber

31130104000

BExBG 05-E 230V AC amber
KSB-307R Light Element LED Red Rotating light

KSB-307R

KSB-307R Light Element LED Red Rotating light
Horn/Strobe 120VAC White

TA880-N5

Horn/Strobe 120VAC White
StreamLine LED Light, Low Profile, UL and cUL, 120VAC, Male Pipe Mount, Green

LP3ML-120G

StreamLine LED Light, Low Profile, UL and cUL, 120VAC, Male Pipe Mount, Green
StreamLine LED Light, Low Profile, UL and cUL, 120VAC, Male Pipe Mount, Red

LP3ML-120R

StreamLine LED Light, Low Profile, UL and cUL, 120VAC, Male Pipe Mount, Red
StreamLine LED Light, Low Profile, UL and cUL, 24VDC, T-Mount, Red

LP3TL-024R

StreamLine LED Light, Low Profile, UL and cUL, 24VDC, T-Mount, Red
Strobe Light, Hazardous Location, UL and cUL CID2, Surface Mount, 120VAC, Clear

151XST-S120C

Strobe Light, Hazardous Location, UL and cUL CID2, Surface Mount, 120VAC, Clear

Frequently Asked Questions

What does IP69K protection mean?

IP69K protects against close-range, powerful, high-temperature water jets and ensures no ingress of dust is permitted.

What environments are suitable for IP69K products?

IP69K products are ideal for applications in Food and Beverage, Wastewater, Pharmaceutical, Marine, Medical Facilities, and Medical Equipment Manufacturing.

How is IP69K protection tested?

Products are dust-tight tested in an Arizona A2 Dust chamber and undergo high-pressure steam jet cleaning at 1160–1450 psi from 4 angles at 4–6 inches, with water temperatures of 176°F (80°C).

What are the benefits of using IP69K products?

IP69K products help reduce product failures due to water/dust ingress, increasing productivity and decreasing production downtime.

What other certifications do Federal Signal products have?

In addition to IP69K, Federal Signal products are designed to meet or exceed UL, CSA, CSFM, IECEx, and other global certifications, and are ISO 9001 Certified.

Is the 191XL suitable for hazardous locations?

Yes, the 191XL is listed as a Hazardous Location LED Light.

What is the IP rating of the 191XL?

Federal Signal products, including the 191XL, are designed to meet the IP69K rating, which is the highest standard for ingress protection.

How to Install the 191XL Series LED Beacon

This guide provides step-by-step instructions for installing and wiring the 191XL Series LED Beacon in hazardous locations.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Conductive sealant

  1. Unpack and Inspect the Beacon

    Carefully unpack the beacon and inspect it for any damage that may have occurred during transit. Do not proceed with installation if the beacon is damaged.

  2. Mount the Beacon

    Choose a suitable location for the beacon. For pipe mounting, ensure the mating threads are clean, apply conductive sealant to the conduit threads, and secure the beacon to a 3/4" pipe using the set screw. For surface mounting, use the mounting base as a template to mark and drill two 9/32 inch holes, then secure the beacon with the supplied hardware.

  3. Wiring the Beacon

    Ensure power is off before connecting wires. For 120-240 Vac models, connect the black lead to the hot side and the white lead to the neutral side of the power source. For 24 Vac/dc models, connect the red lead to the positive side and the black lead to the negative side. If applicable, connect the green/yellow lead to earth ground.

  4. Reconnect Power and Test

    After completing the wiring, ensure all connections are secure and the beacon is properly closed. Reconnect power to the beacon and test its operation to ensure it is functioning correctly.

  5. Calibrate the Beacon

    If necessary, change the beacon from Flash Mode to Steady Mode by disconnecting power, removing the dome assembly, and adjusting the jumper on the printed circuit board as per the instructions. Reassemble and test the beacon again.

Frequently Asked Questions about Federal Signal

What certifications and standards do Federal Signal products comply with?

Federal Signal products are certified across multiple international standards, including UL (Underwriters Laboratories) in the USA, CSA (Canadian Standards Association), CE (European Community), UKCA (United Kingdom), EAC (Russia), and C-Tick (Australia and New Zealand). Their products meet rigorous safety and performance standards for industrial environments, with specific compliance in electrical equipment enclosures, functional safety, and environmental protection ratings.

What is Federal Signal's warranty policy?

Federal Signal offers a comprehensive limited warranty covering most products for 1-5 years from the date of delivery, with specific terms varying by product category. Mechanical sirens, beacons, speakers, and sounders typically receive 5-year parts and labor coverage, while electronic sirens and controllers generally have 2-year warranties. All warranties require return to the factory for service, and on-site services are not included. Certain components like domes, lenses, lamps, and batteries are specifically excluded from warranty coverage.

What industries and applications are Federal Signal products used for?

Federal Signal products are used across multiple critical industrial and municipal sectors for notification, communication, and safety systems. Their product lines cover essential applications including fire alarm systems, public address and telephony, outdoor warning systems, visual and audible signals, and emergency communication networks. Key industries served include manufacturing, municipal emergency services, industrial facilities, and infrastructure environments where clear, reliable communication and safety signaling are paramount.

What technical support does Federal Signal offer?

Federal Signal offers comprehensive technical support through their dedicated [email protected] email and direct phone line at +1 708.534.4756. Their support covers a wide range of notification and communication solutions, including technical assistance for products in public address, telephony, fire alarm, visual and audible signals, outdoor warning systems, and intercoms.

What are the main product lines offered by Federal Signal?

Federal Signal offers comprehensive notification and communication solutions across multiple product lines, including Visual Signals, Audible Signals, Telephony, Intercoms, Fire Alarm, Outdoor Warning Systems, Public Address, and Initiating Systems. Their product range is designed to provide clear communications and critical process notifications that enhance safety and compliance in industrial and public environments.

What are the key features of Federal Signal products?

Federal Signal products are comprehensive notification solutions designed to enhance safety and communication across industrial environments. Their key features include visual and audible signals, fire alarm systems, outdoor warning systems, public address capabilities, telephony, and intercoms. These products provide critical process notifications, ensure safety compliance, and offer advanced technologies like secure encrypted communication, cloud-based control systems, and customizable emergency response interfaces.

What environmental ratings do Federal Signal products have?

Federal Signal products offer robust environmental ratings across multiple standards, including UL 508A, CSA, NEMA, and IEC 60529. Their enclosures are rated for Type 1, 2, 3, 4, 4X, 12, and 13 environments, with IP66 protection, and can operate in temperatures ranging from -40°F to 266°F. These ratings ensure superior protection against dust, water, corrosion, and extreme conditions for indoor and outdoor industrial applications.

What accessories are available for Federal Signal products?

Federal Signal offers multiple accessories for their signaling products, including coupling kits, cable entry adapters, indicator rings, legend plates, and mounting brackets. Key accessories include E-Box endcap kits with M20 and M25 openings, U-Brackets for dual configurations, and color-coded indicator rings in black, blue, green, magenta, red, and yellow. Additional options like adapters for NPT connections and specialized mounting hardware are also available for their Global Series signaling platforms.

What communication protocols do Federal Signal products support?

Federal Signal supports multiple industrial communication protocols including PROFIBUS DP, PROFINET, EtherNet/IP, CANopen, and Modbus RTU. These protocols enable flexible network integration across various industrial automation environments, supporting both traditional fieldbuses and modern Ethernet-based communication standards.

How are Federal Signal products typically installed?

Federal Signal products are typically installed using professional mounting configurations that include wall brackets, base stations, and specialized mounting hardware. Depending on the specific product line—such as outdoor warning systems, visual signals, or audible signals—installation involves precise mounting options like wall-mount antenna brackets, base station radio packages, and modular component assemblies. Each product configuration includes specific mounting accessories like endcaps, adapters, and terminal blocks to ensure secure and compliant installation in industrial and safety-critical environments.