Contact for Pricing
Overview
- ATEX-certified for hazardous areas (Zones 1, 2, 21, 22)
- Precise temperature control for industrial applications
- Robust construction for durability in harsh environments
- DIN rail mounting for easy installation
- Manufactured in Denmark (DK) by Danfoss
Specifications
Ip Rating | ATEX |
Series | OPT-AF-V:STO |

39524
6-32 Square Drive Round Head Machine Screw Kit, 1/2" (100), 3/4" (90), 1" (65), 1-1/4" (50), 1-1/2" (40) and 2" (35), Zinc PlateFrequently Asked Questions
What safety functions does the OPTAF option board provide?
The OPTAF option board provides Safe Torque Off (STO) and Safe Stop 1 (SS1) safety functions, along with motor thermistor overtemperature protection for ATEX certified motors.
What standards does the STO safety function comply with?
The STO safety function is designed for use in accordance with EN 61800-5-2 (SIL3), EN ISO 13849-1 (PL 'e' Category 3), EN 62061 (SILCL3), and IEC 61508 (SIL3).
What standards does the SS1 safety function comply with?
The SS1 safety function is designed for use in accordance with EN 61800-5-2 (SIL3), EN ISO 13849-1 (PL 'e' Category 3), EN 62061 (SILCL3), and IEC 61508 (SIL3).
How is the STO safety function achieved?
The STO safety function is achieved by disabling the drive modulation through two independent paths controlled by SD1 and SD2 inputs, preventing the drive from generating torque.
What is the principle of the Safe Stop 1 (SS1) function?
SS1 initiates motor deceleration and then activates the STO function after a user-set time delay, corresponding to a controlled stop (stop category 1).
What is the purpose of the thermistor input on the OPTAF board?
The thermistor input is for overtemperature detection of ATEX certified motors, acting as a tripping device.
What are the input voltage levels for the STO function?
The input voltage for logic 1 is typically 24 V (11-30 V), and for logic 0 it is typically 0 V (-3-3 V).
What is the response time for the STO safety function?
The activation time for the STO safety function is less than 20 ms, and the de-activation time is 1000 ms.
How is the thermistor input disabled if not used?
If the thermistor input is not used, it must be disabled by making a short circuit to the terminals and setting jumper X10 to the 'OFF' state.
What is the maximum voltage and current for the thermistor input?
The maximum voltage for the thermistor input is 10 V, and the maximum current is 6.7 mA.
Frequently Asked Questions about Danfoss
What certifications and standards do Danfoss products comply with?
Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).
What certifications and standards do Danfoss products comply with?
Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).
What communication protocols do Danfoss products support?
Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.
What certifications and standards do Danfoss products comply with?
Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.
What industries and applications are Danfoss products used for?
Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.
What are the key features of Danfoss products?
Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.
What environmental ratings do Danfoss products have?
Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.
What accessories are available for Danfoss products?
Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.
What are the main product lines offered by Danfoss?
Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.
What is Danfoss's warranty policy?
Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.