Authorized Danfoss Distributor
Danfoss 136Z4317 - VLT® Soft Starter MCD 500/600, 700 HP, 1154 A, 200-525 V, 24 V control, bypassed, IP00, frame S3

Danfoss 136Z4317 VLT® Soft Starter MCD 500/600, 700 HP, 1154 A, 200-525 V, 24 V control, bypassed, IP00…

Alternate Item Number: MCD61154BT5S3X00CV1


Documents & Media
Installation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Danfoss VLT® Soft Starter MCD 600 (SKU: 136Z4317) is an internally bypassed soft starter for motors up to 700 HP and 1154 A continuous current. Operates on 200-525 VAC mains with 24 V DC control supply, separate from motor circuit. Applications: pumps, fans, compressors, conveyors. Internal bypass contactor carries motor current post-ramp, reducing SCR heat and eliminating external bypass contactor. Minimizes steady-state heat and installation costs. Features Adaptive Acceleration Control (AAC) with early, constant, and late acceleration profiles. Built-in motor and starter protections. Fieldbus options: Modbus, PROFIBUS, EtherNet/IP, DeviceNet. Supplied as open chassis (IP00) for customer-provided enclosure. Frame S3 optimized for high-current applications. Type code MCD61154BT5S3X00CV1. Compatible with VLT® Local Control Panel LCP 601 for local programming/monitoring via 3 m cable.
  • Internally bypassed soft starter for 700 HP, 1154 A motors
  • Operates on 200-525 VAC mains with 24 V DC control supply
  • Reduces starting current and water hammer in pumps, fans, compressors
  • Built-in bypass contactor minimizes heat and installation costs
  • Supports Modbus, PROFIBUS, EtherNet/IP, DeviceNet communication

Specifications

Bypass
Internally bypassed
Continuous Amps
1154
Control Voltage
24 V
Current Rating
1154 A
Enclosure
0
Frame Size
S3
Horsepower
700 HP
IP Rating
IP00
Mounting Type
Open chassis (internal mounting)
Phase
3
Phases and main voltage
200-525 V
Product Line
VLT® Soft Starter (MCD series)
Product Line
500 Volt Built in Bypass
Series
VLT® Soft Starter MCD 500/600
Series
SOFT STARTERS
Size
S3
Type Code
MCD61154BT5S3X00CV1
Voltage
500 Volt Built in Bypass
Voltage Rating
200-525 V
VLT® Soft Starter MCD 500/600, 700 HP, 1134 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S3

136Z4313

VLT® Soft Starter MCD 500/600, 700 HP, 1134 A, 200-525 V, 110-240 V control, non-bypassed, IP00, frame S3
STANDARD PANEL GPH2350PC4000 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 350 HP; Main voltage 460 V; Bypass type AC3; Control options Start Pushbutton, Stop Pushbutton, Run Light and Fault Light; Enclosure rating Type 4

GPH2350PC4000

STANDARD PANEL GPH2350PC4000 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 350 HP; Main voltage 460 V; Bypass type AC3; Control options Start Pushbutton, Stop Pushbutton, Run Light and Fault Light; Enclosure rating Type 4
PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.

X125-B4-48-ND

PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.
MTR DIN MT SOFT START 480V 12A

RSE4812-B

MTR DIN MT SOFT START 480V 12A
VLT® Soft Starter MCD 500/600, 500 HP, 839 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S3

136Z4327

VLT® Soft Starter MCD 500/600, 500 HP, 839 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S3
VLT® Soft Starter MCD 500/600, 600 HP, 950 A, 380-690 V, 110-240 V control, bypassed, IP00, frame S3

136Z4332

VLT® Soft Starter MCD 500/600, 600 HP, 950 A, 380-690 V, 110-240 V control, bypassed, IP00, frame S3
VLT® Soft Starter MCD 500/600, 700 HP, 1134 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S3

136Z4329

VLT® Soft Starter MCD 500/600, 700 HP, 1134 A, 200-525 V, 24 V control, non-bypassed, IP00, frame S3
VLT® Soft Starter MCD 500/600, 450 HP, 654 A, 380-690 V, 110-240 V control, bypassed, IP00, frame S3

136Z4330

VLT® Soft Starter MCD 500/600, 450 HP, 654 A, 380-690 V, 110-240 V control, bypassed, IP00, frame S3

Frequently Asked Questions

Do Danfoss soft starters generate harmonics?

No, Danfoss soft starters generate zero harmonics, eliminating the need for filters and screened cables.

Can I program the soft starter via PC?

Yes, you can program the soft starter via your PC using the VLT® Motion Control Tool MCT 10 set-up software.

Does the soft starter offer integrated bypass functionality?

Yes, many Danfoss soft starters provide an integrated bypass for direct-on-line operation after start-up.

What is the purpose of the Pump Clean function on MCD 600?

The Pump Clean function automatically runs the motor in reverse/forward to clear a blocked pump.

What is the maximum current rating for Danfoss soft starters?

Danfoss soft starters are available with ratings up to 1250 A.

What is the voltage range for VLT® Soft Starter MCD 600?

The MCD 600 has a mains voltage range of 3 x 200-525 VAC (T5) and 3 x 380-690 VAC (T7).

What is the current range for VLT® Soft Starter MCD 600?

The MCD 600 has a current range of 20-129 A (nominal) for IP20 enclosures and 144-1250 A (nominal) for IP00 enclosures.

What is the power range for Eltwin SMC Soft Starter?

The Eltwin SMC Soft Starter is for AC motors up to 11 kW, with a power range of 0.1-11 kW @ 400 V.

How does integrated bypass save energy?

Integrated bypass allows switching to direct-on-line operation after start-up, reducing losses and heat dissipation.

Can the MCD 600 run motors in reverse?

Yes, the MCD 600 can run motors in both forward and reverse directions with full control over starting current and protection.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.