Danfoss 136H9377 - VLT® AQUA Drive FC 202, 45 kW / 60 HP, Three phase 525-600V, IP 55/NEMA Type 12, No brake chopper included, Graphical local control panel, No coated PCB, Mains disconnect and fuse, standard controller, Standard cable entries, 62 A continuous, frame C1

Danfoss 136H9377 VLT® AQUA Drive FC 202, 45 kW / 60 HP, Three phase 525-600V, IP 55/NEMA Type 12, No…

Alternate Item Number: FC-202P45KT6E55HXXGX3XXSXXXXAXBXCXXXXDX


Documents & Media
Technical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® AQUA Drive FC 202 (SKU: 136H9377) is a dedicated variable frequency drive (VFD) engineered for water and wastewater applications, delivering precise motor control for pumps, fans, and compressors. This 45 kW (60 HP) three-phase drive operates on 525–600V mains, with a continuous current rating of 62 A and frame size C1. The IP55/NEMA Type 12 enclosure resists dust and water jets, enabling wall mounting in plant environments without requiring a control room panel. Key features include a graphical local control panel (LCP-102) for plain-language readouts and parameter cloning, simplifying commissioning and reducing downtime during replacements or system expansions. The integrated mains disconnect and fuses eliminate external components, saving panel space and wiring complexity. The drive supports cascade control for multi-pump sets, pipe-fill mode to prevent water hammer, dry-run and end-of-curve detection, and deragging to clear impeller blockages—critical functions for water infrastructure reliability. The FC 202 is configured to order, with the type code FC-202P45KT6E55HXXGX3XXSXXXXAXBXCXXXXDX defining this exact build. Other configurations (e.g., with brake chopper, Safe Torque Off, or different enclosures) are available. For high-power applications up to 800 kW, the FC 202 scales to meet larger system demands. Ideal for municipal water treatment, irrigation systems, and industrial pumping stations, the FC 202 ensures energy efficiency, operational flexibility, and long-term reliability in harsh environments.
  • 45 kW (60 HP) three-phase drive for 525–600V mains, 62 A continuous current
  • IP55/NEMA Type 12 enclosure for wall mounting in plant environments
  • Graphical LCP-102 with parameter cloning for fast commissioning
  • Integrated mains disconnect and fuses reduce panel space and wiring
  • Pumping-specific functions: cascade control, pipe-fill mode, dry-run detection, deragging

Specifications

Braking
No brake chopper included
C option software
standard controller
Color
Blue
Connection Type
Standard cable entries
Connection Type
Screw Terminal
Continuous Amps
62
Current Rating
62 A
Current Rating
45 A
Enclosure
IP 55/NEMA Type 12
Enclosure
IP-55 NEMA 12
Enclosure Code
E55
Frame Size
C1
Hardware option A
Standard cable entries
Horsepower
60 HP
IP Rating
IP55
IP Rating
IP66
LCP Display
Graphical local control panel
Mains input
Mains disconnect and fuse
Material
Poly
Mounting Type
Wall Mounting
Mounting Type
Surface Mount
Nema Rating
Type 4X
Nema Rating
Type 12
PCB Coating
No coated PCB
Phases and main voltage
Three phase 525-600V
Power Code
P45K
Power size
45 kW / 60 HP
Product Line
VLT® AQUA Drive FC 202
Product Line
Pump Drive 600V 3 Phase w/ Fused Disconnect
Series
VLT AQUA Drive FC 202
Series
FC-202
Series
FC202
Type Code
FC-202P45KT6E55HXXGX3XXSXXXXAXBXCXXXXDX
Voltage
600V 3 Phase w/ Fused Disconnect
Voltage Rating
525-600 VAC
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating temperature range without derating?

VLT® AQUA Drives up to 315 kW can operate in ambient temperatures from -25 to 50 °C without derating.

What is the benefit of the back-channel cooling system?

The back-channel cooling system exhausts 90% of system heat outside, reducing the need for air conditioning and lowering installation costs.

What is the purpose of the deragging function?

The deragging function performs impeller washing cycles to maintain pump efficiency, extend maintenance intervals, and increase pump lifetime.

Can the drive be installed outdoors?

Yes, VLT® AQUA Drives are available in protection ratings up to IP66/NEMA 4X for direct outdoor installation.

What is the maximum cable length for installation?

The drive supports cable lengths up to 150 m screened and 300 m unscreened without additional components.

How much energy can be saved annually with this drive?

The VLT® AQUA Drive can deliver energy savings of up to 15% of the drive setup investment annually.

How does the Advanced Active Filter (AAF) work?

AAF monitors supply current, identifies distortion, and injects counter-phase currents to cancel harmonics, restoring the AC power waveform.

What is the THDi for VLT® low harmonic drives?

VLT® low harmonic drives provide a total harmonic current distortion (THDi) of a maximum of 5%.

What is the benefit of SmartStart function?

The SmartStart function saves installation time and hassle with user-friendly commissioning, accessible wirelessly from a mobile device.

What are the energy savings for water supply pumps?

Regulating pump speed with VLT® AQUA Drive can achieve major energy savings of around 40% by regulating pressure.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.