Authorized Danfoss Distributor
Danfoss 136G7348 - VLT® Soft Starter MCD 500/600, 30 HP, 69 A, 200-525 V, 110-240 V control, bypassed, IP20, frame S1

Danfoss 136G7348 VLT® Soft Starter MCD 500/600, 30 HP, 69 A, 200-525 V, 110-240 V control, bypassed…

Alternate Item Number: MCD60069BT5S1X20CV2


Documents & Media
Installation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® Soft Starter MCD 500/600 (SKU 136G7348) is a bypassed soft starter designed for fixed-speed motor applications up to 30 HP (69 A continuous). It supports mains voltages from 200-525 V, making it suitable for a wide range of industrial systems without requiring voltage-specific variants. Key features include an internal bypass contactor that reduces heat generation by carrying motor current only during startup, ensuring cooler operation and extended component life. The control supply operates independently on 110-240 V AC, allowing compatibility with common panel control voltages. This unit is ideal for applications where starting current or water hammer is a concern, such as pumps, fans, compressors, and conveyors. The MCD 500/600 supports up to 480 starts per hour for motors rated ≤25 A, with no derating required. It includes built-in protections for motor and starter reliability, ensuring consistent performance in demanding environments. Configuration is flexible, with options for communication cards and smart application cards to enhance functionality.
  • 30 HP (69 A continuous) motor rating with 200-525 V mains compatibility
  • Internal bypass contactor reduces heat and power loss during operation
  • Control supply: 110-240 V AC (separate from motor circuit)
  • Supports up to 480 starts/hour for ≤25 A motors without derating
  • UNSPSC code: 39121521

Specifications

Bypass
Internally bypassed
Connection Type
Internal bypassed
Continuous Amps
69
Control Voltage
110-240 V
Current Rating
69 A
Enclosure
20
Frame Size
S1
Horsepower
30 HP
IP Rating
IP20
Mounting Type
Frame S1
Phase
3
Phases and main voltage
200-525 V
Product Line
VLT® Soft Starter (MCD series)
Product Line
500 Volt Built in Bypass
Series
MCD60069BT5S1X20CV2
Series
VLT® Soft Starter MCD 500/600
Series
SOFT STARTERS
Type Code
MCD60069BT5S1X20CV2
Voltage
500 Volt Built in Bypass
Voltage Rating
200-525 V
VLT® Soft Starter MCD 500/600, 30 HP, 69 A, 200-525 V, 24 V control, bypassed, IP20, frame S1

136G7338

VLT® Soft Starter MCD 500/600, 30 HP, 69 A, 200-525 V, 24 V control, bypassed, IP20, frame S1
STANDARD PANEL GPH2030QC4001 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 30 HP; Main voltage 460 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light, Fault Light and Keypad; Enclosure rating Type 4

GPH2030QC4001

STANDARD PANEL GPH2030QC4001 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 30 HP; Main voltage 460 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light, Fault Light and Keypad; Enclosure rating Type 4
PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.

X125-B4-48-ND

PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.
MTR DIN MT SOFT START 480V 3A

RSE4803-B

MTR DIN MT SOFT START 480V 3A
VLT® Soft Starter MCD 500/600, 40 HP, 86 A, 200-525 V, 110-240 V control, bypassed, IP20, frame S1

136G7349

VLT® Soft Starter MCD 500/600, 40 HP, 86 A, 200-525 V, 110-240 V control, bypassed, IP20, frame S1
VLT® Soft Starter MCD 500/600, 60 HP, 129 A, 200-525 V, 110-240 V control, bypassed, IP20, frame S1

136G7350

VLT® Soft Starter MCD 500/600, 60 HP, 129 A, 200-525 V, 110-240 V control, bypassed, IP20, frame S1
VLT® Soft Starter MCD 500/600, 75 HP, 171 A, 200-525 V, 110-240 V control, bypassed, IP00, frame S2

136G7351

VLT® Soft Starter MCD 500/600, 75 HP, 171 A, 200-525 V, 110-240 V control, bypassed, IP00, frame S2
VLT® Soft Starter MCD 500/600, 150 HP, 323 A, 200-525 V, 110-240 V control, bypassed, IP00, frame S2

136G7353

VLT® Soft Starter MCD 500/600, 150 HP, 323 A, 200-525 V, 110-240 V control, bypassed, IP00, frame S2

Frequently Asked Questions

What are the benefits of using a soft starter?

Soft starters reduce mechanical stress, extend system lifetime, minimize penalty from utilities, and reduce water hammer in pump applications.

Do soft starters generate harmonics?

No, soft starters generate zero harmonics, eliminating the need for filters and screened cables.

What is the maximum current rating for Danfoss soft starters?

Danfoss soft starters are available with ratings up to 1250 A.

How does an integrated bypass save energy?

The integrated bypass allows switching to direct-on-line operation after start-up, reducing energy losses and cooling requirements.

Can soft starters be programmed via PC?

Yes, soft starters can be programmed using the VLT® Motion Control Tool MCT 10 set-up software.

What is the voltage range for the VLT® Soft Starter MCD 600?

The MCD 600 has a mains voltage range of 3 x 200-525 VAC or 3 x 380-690 VAC.

What is the power range for the Eltwin SMC Soft Starter?

The Eltwin SMC Soft Starter is designed for AC motors up to 11 kW.

What communication options are available for MCD 600?

MCD 600 supports various Ethernet and serial communication options including PROFIBUS, PROFINET, and EtherNet/IP.

How is the soft starter selected based on motor current?

Select a soft starter with a current rating at least equal to the motor’s full load current rating at the application's start duty.

What is the payback period for a soft starter with integrated bypass?

The payback period for a soft starter with integrated bypass is typically only a few months.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.