Authorized Danfoss Distributor
Danfoss 134X0718 - VLT® Midi Drive FC 280, 7.5 kW / 10 HP, 3 x 380/480V AC, IP20 Chassis/Open, RFI-Filter, Class A2 (C3), Brake IGBT, No LCP installed, Standard cable entries, EtherNet/IP™, 14 A continuous, frame K3

Danfoss 134X0718 VLT® Midi Drive FC 280, 7.5 kW / 10 HP, 3 x 380/480V AC, IP20 Chassis/Open, RFI-Filter…

Alternate Item Number: FC-280P7K5T4E20H2BXCXXXSXXXXAN


Documents & Media
Technical BulletinInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® Midi Drive FC 280 (SKU: 134X0718) is a compact, high-performance AC drive designed for machine builders requiring a small cabinet footprint with built-in fieldbus connectivity. Rated at 7.5 kW (10 HP) with a continuous output current of 14 A, this drive operates on a 3-phase 380/480V AC supply and is supplied as a protected chassis (IP20/Open) for mounting inside control panels or switchgear enclosures. The FC 280 features an integrated EtherNet/IP interface, eliminating the need for additional fieldbus cards and simplifying integration with Allen-Bradley/Rockwell automation systems. Key features include a built-in RFI filter rated for Class A2 (C3), suitable for industrial environments with dedicated transformers. For applications sharing power networks with residential or light-commercial loads, additional filtering may be required. The drive is equipped with a brake IGBT, enabling fast stops on high-inertia or overhauling loads such as centrifuges, hoists, unwinders, and fast-cycling conveyors without tripping on DC-link overvoltage. The unit is supplied without a local control panel (LCP), allowing operation via PLC or door-mounted HMI, with the option to add an LCP later for commissioning or maintenance. The FC 280 is configured to order, with the type code FC-280P7K5T4E20H2BXCXXXSXXXXAN specifying this exact build. Danfoss drives are not stocked as fixed catalogue items; instead, configurations are built to order based on application requirements. Typical applications include material handling, packaging, and industrial machinery where space efficiency, communication flexibility, and reliable braking performance are critical. For configuration assistance, Danfoss provides an online configurator at www.danfossdrives.com, ensuring compatibility with specific system requirements.
  • 7.5 kW (10 HP) output, 14 A continuous current, 3x380-480V AC input
  • Integrated EtherNet/IP interface for direct Allen-Bradley/Rockwell integration
  • IP20/Open chassis design for panel or switchgear mounting
  • Built-in RFI filter (Class A2/C3) for industrial environments
  • Brake IGBT for fast stops on high-inertia loads (centrifuges, hoists, conveyors)

Specifications

AC Line Voltage
3 x 380/480V AC
Braking
Brake IGBT
Connection Type
Standard cable entries
Continuous Amps
14
Current Rating
14 A
Enclosure
IP20 Chassis/Open
Enclosure Code
E20H2BX
Frame Size
K3
Hardware option A
Standard cable entries
Horsepower
10 HP
Integrated fieldbus
EtherNet/IP™
IP Rating
IP20
LCP Display
No LCP installed
Mounting Type
Chassis/Open (for panel mounting)
Power Code
P7K5
Power size
7.5 kW / 10 HP
Product Line
VLT® Midi Drive FC 280
Product Line
Compact Drive 460V 3 Phase w/ Ethernet IP
RFI filter
RFI-Filter, Class A2 (C3)
Series
FC-280P7K5T4E20H2BXCXXXSXXXXAN
Series
FC280
Series
VLT® Midi Drive FC 280
Type Code
FC-280P7K5T4E20H2BXCXXXSXXXXAN
Voltage
460V 3 Phase w/ Ethernet IP
Voltage Rating
380-480 VAC
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating temperature range for the VLT® Midi Drive FC 280?

The drive operates at 45 °C ambient temperature at full load and 55 °C with derating. This means no extra cooling equipment or oversizing is needed.

How does the VLT® Midi Drive FC 280 handle harmonic mitigation?

It includes integrated DC chokes for 3-phase units and active power factor correction (PFC) for single-phase units, eliminating the need for additional components.

Is the VLT® Midi Drive FC 280 compatible with older VLT® 2800 drives?

Yes, the VLT® Midi Drive is designed for compatibility with the VLT® 2800 for a fast and streamlined retrofit, including exterior dimensions and software tools.

What are the supply voltage options for the VLT® Midi Drive FC 280?

The drive supports 200-240 V AC (single-phase or three-phase) and 380-480 V AC (three-phase) supply voltages.

Can the VLT® Midi Drive FC 280 be mounted side-by-side without derating?

Yes, the compact design allows for side-by-side or horizontal mounting with zero clearance between drives, without requiring derating.

What communication protocols are integrated as standard in the VLT® Midi Drive FC 280?

Modbus RTU and FC Protocol are integrated as standard. Other fieldbus options like PROFINET, POWERLINK, EtherNet/IP™, EtherCAT, and PROFIBUS are also available.

Does the VLT® Midi Drive FC 280 support functional safety features?

Yes, it features dual-channel Safe Torque Off (STO) functional safety, designed to meet SIL 2 and Category 3 PL d requirements.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.