Danfoss 134F6395 - VLT® AQUA Drive FC 202, 0.75 kW / 1.0 HP, Three phase 200-240V, IP 66, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Imperial cable entries, 4.6 A continuous, frame A5

Danfoss 134F6395 VLT® AQUA Drive FC 202, 0.75 kW / 1.0 HP, Three phase 200-240V, IP 66, No additional EMC…

Alternate Item Number: FC-202PK75T2E66H2XGXXSXSXXXXAXBXCXXXXDX


Documents & Media
Technical BulletinSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Danfoss VLT® AQUA Drive FC 202 (SKU 134F6395) is a dedicated variable frequency drive (VFD) for water and wastewater applications, engineered to optimize pump system performance with precision control and robust durability. This 0.75 kW (1.0 HP) drive operates on three-phase 200-240V power, delivering 4.6 A continuous output with a frame size A5. Key features include cascade control for multi-pump setups, pipe-fill mode to prevent water hammer, dry-run and end-of-curve detection, and deragging functionality to clear impeller blockages. The graphical local control panel (LCP-102) provides plain-language readouts and enables parameter cloning for rapid commissioning or unit replacement. The drive meets EN 55011 Class A2 and EN/IEC 61800-3 Category 3 emissions standards without an integrated EMC filter, making it suitable for second-environment industrial supplies with dedicated transformers. For shared networks with residential or light-commercial loads, additional filtering is required. The FC 202 is configured to order with a type code (e.g., FC-202PK75T2E66H2XGXXSXSXXXXAXBXCXXXXDX) and assigned a quick order number (134F6395) for streamlined procurement. It excludes a brake chopper and features imperial cable entries, standard controller, and a non-coated PCB. This drive is ideal for municipal water treatment, irrigation systems, and industrial pumping applications where reliability, efficiency, and ease of maintenance are critical.
  • 0.75 kW (1.0 HP) output, 4.6 A continuous, frame A5
  • Cascade control for multi-pump systems, pipe-fill mode, dry-run detection
  • Graphical LCP-102 with parameter cloning for rapid commissioning
  • Meets EN 55011 Class A2 and EN/IEC 61800-3 Category 3 emissions
  • Durable poly material construction with screw terminal connections

Specifications

Braking
No brake chopper included
C option software
standard controller
Color
Blue
Connection Type
Screw Terminal
Continuous Amps
4.6
Current Rating
75 A
Enclosure
IP 66
Enclosure
IP-66 NEMA 4X
Enclosure Code
E66
Frame Size
A5
Hardware option A
Imperial cable entries
Horsepower
1 HP
LCP Display
Graphical local control panel
Material
Poly
Nema Rating
Type 4X
PCB Coating
No coated PCB
Phases and main voltage
Three phase 200-240V
Poles
2P+G
Power Code
PK75
Power size
0.75 kW / 1.0 HP
Product Line
Pump Drive 230V 3 Phase
Product Line
VLT® AQUA Drive FC 202
RFI filter
No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3
Series
FC202
Series
FC-202
Type Code
FC-202PK75T2E66H2XGXXSXSXXXXAXBXCXXXXDX
Voltage
230V 3 Phase
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating temperature range for VLT® AQUA Drives up to 315 kW?

VLT® AQUA Drives up to 315 kW can operate in ambient temperatures from -25 to 50 °C without derating.

How does the back-channel cooling system reduce energy consumption?

The back-channel cooling system exhausts up to 90% of heat outside, significantly reducing the need for air conditioning.

What is the purpose of the deragging function in VLT® AQUA Drive?

The deragging function performs impeller washing cycles to maintain pump efficiency, extend lifetime, and reduce manual maintenance.

What is the maximum cable length supported by VLT® AQUA Drive?

The VLT® AQUA Drive supports cable lengths up to 150 m screened and 300 m unscreened.

What level of PCB protection is standard on VLT® AQUA Drives 90 kW and larger?

VLT® AQUA Drives 90 kW and larger come with 3C3 PCB coating as standard for long lifetime in harsh environments.

What is the THDi for VLT® low harmonic drives?

VLT® low harmonic drives provide a total harmonic current distortion (THDi) of a maximum of 5%.

Can VLT® AQUA Drives be installed outdoors?

Yes, VLT® AQUA Drives are available in protection ratings up to IP66/NEMA 4X, allowing for direct outdoor installation.

How does the Advanced Automatic Motor Adaption work?

The drive automatically adapts to the motor using VVC+ control and advanced motor data analysis for optimal and efficient performance.

What is the typical energy saving from VLT® AQUA Drive compared to traditional AC drives?

The VLT® AQUA Drive offers cost savings of up to 15% compared to traditional AC drives due to its design and features.

What is the benefit of the Smart Logic Controller feature?

The integrated Smart Logic Controller (micro PLC) functionality eliminates the need for an external PLC and IO module, saving costs.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.