Authorized Danfoss Distributor
Danfoss 132H2252 - VLT® Soft Starter (MCD series), 150 HP, frame SE

Danfoss 132H2252 VLT® Soft Starter (MCD series), 150 HP, frame SE

Alternate Item Number: MCD60180BTXSES12CVE


Documents & Media
Installation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

Danfoss VLT® MCD series soft starter (SKU 132H2252) is a 150 HP, frame SE motor control device designed to reduce inrush current and mechanical stress during motor startup. Unlike variable frequency drives, it provides cost-effective, across-the-line operation after ramp-up, ideal for applications where starting current or water hammer is a concern. This unit is configured to order with the type code MCD60180BTXSES12CVE, matching Danfoss' modular build system. It is rated for 50% overload at 150 HP (110 kW) per NEC/NEMA standards, housed in an FR9 enclosure. The soft starter eliminates the need for complex programming while delivering reliable motor protection and energy efficiency in industrial automation systems.
  • 150 HP (110 kW) rated soft starter for industrial motors
  • Reduces inrush current and mechanical stress during startup
  • 50% overload capacity per NEC/NEMA standards
  • Frame SE, FR9 enclosure size
  • Configured-to-order via Danfoss type code MCD60180BTXSES12CVE

Specifications

Frame Size
SE
Horsepower
150 HP
Product Line
Enclosed 480 Volt Built in Bypass
Product Line
VLT® Soft Starter (MCD series)
Series
SOFT STARTERS
Series
MCD
Size
SE
Type Code
MCD60180BTXSES12CVE
Voltage
480 Volt Built in Bypass
VLT® Soft Starter (MCD series), 150 HP, frame SE

132H2257

VLT® Soft Starter (MCD series), 150 HP, frame SE
STANDARD PANEL GPH2150QC4000 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 150 HP; Main voltage 460 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light and Fault Light; Enclosure rating Type 4

GPH2150QC4000

STANDARD PANEL GPH2150QC4000 WEG specifications: Panel type SOFT-STARTER; Horsepower (HP) 150 HP; Main voltage 460 V; Bypass type None; Control options Start Pushbutton, Stop Pushbutton, Run Light and Fault Light; Enclosure rating Type 4
PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.

X125-B4-48-ND

PSTX normal duty enclosed softstarters are the ultimate softstarting solution. Includes all features of the PSTX normal duty, sized for normal duty applications. Both the PSTX softstarter and TMAX XT breakers are utilized. Door mounted pilot devices include PSTX keypad, hand-off-auto selector switch, start and stop pushbuttons, power on pilot light, run pilot light and fault pilot light. Good for Normal Duty class 10 starts for 150HP/192A, heavy duty class 30 starts for 125HP/169A, SSCR rating of 65kA, 480V and type 4 enclosure.
MTR DIN MT SOFT START 480V 12A

RSE4812-B

MTR DIN MT SOFT START 480V 12A
VLT® Soft Starter (MCD series), 100 HP, frame SE

132H8440

VLT® Soft Starter (MCD series), 100 HP, frame SE
VLT® Soft Starter (MCD series), 200 HP, frame SE

132H2253

VLT® Soft Starter (MCD series), 200 HP, frame SE
VLT® Soft Starter (MCD series), 50 HP, frame SE

132H2255

VLT® Soft Starter (MCD series), 50 HP, frame SE
VLT® Soft Starter (MCD series), 200 HP, frame SE

132H2258

VLT® Soft Starter (MCD series), 200 HP, frame SE

Frequently Asked Questions

Do Danfoss soft starters generate harmonics?

No, Danfoss soft starters generate zero harmonics, eliminating the need for filters and screened cables.

Can a soft starter be bypassed after startup?

Yes, after start-up, the soft starter can be bypassed, switching over to run direct-on-line.

What is the voltage range for VLT® Soft Starter MCD 600?

The VLT® Soft Starter MCD 600 has a mains voltage range of 3 x 200-525 VAC (T5) and 3 x 380-690 VAC (T7).

What is the purpose of the Pump Clean function?

The Pump Clean function helps to clear blocked pumps by automatically running the motor alternately in reverse and forward.

Can I program the soft starter via PC?

Yes, you can program the soft starter via your PC using the VLT® Motion Control Tool MCT 10 set-up software.

What is the voltage range for VLT® Compact Starter MCD 201/202?

The VLT® Compact Starter MCD 201 and 202 operate with a mains voltage range of 3 x 200 - 575 VAC.

How does the Power Through function work?

The Power Through function bypasses damaged SCRs to keep the motor running when immediate repair is not possible.

What is the current rating for VLT® Soft Starter MCD 600 IP20 enclosure?

For the IP20 enclosure, the VLT® Soft Starter MCD 600 has a nominal current range of 20-129 A.

What is the maximum current rating for Danfoss soft starters?

The Danfoss portfolio of soft starters offers ratings up to 1250 A.

What are the benefits of using a soft starter?

Soft starters reduce mechanical stress, extend system lifetime, minimize penalty from utilities, and reduce water hammer in pump applications.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.