Danfoss 131F7536 - VLT® AQUA Drive FC 202, 7.5 kW / 10 HP, Three phase 200-240V, IP20, No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3, No brake chopper included, Graphical local control panel, No coated PCB, standard controller, Standard cable entries, 30.8 A continuous, frame B3

Danfoss 131F7536 VLT® AQUA Drive FC 202, 7.5 kW / 10 HP, Three phase 200-240V, IP20, No additional EMC…

Alternate Item Number: FC-202P7K5T2E20H2XGXXXXSXXXXAXBXCXXXXDX


Documents & Media
BrochureTechnical BulletinSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

VLT® AQUA Drive FC 202 — Dedicated to water and wastewater applications. Carries pumping-specific functions other drives do not: cascade control for multi-pump sets, pipe-fill mode to avoid water hammer, dry-run and end-of-curve detection, and deragging to clear impeller blockages. This unit is rated 30.8 A continuous, frame B3 on a Three phase 200-240V supply. Supplied as a protected chassis for mounting inside a control panel or switchgear lineup, which is the usual arrangement where several drives share one enclosure and its cooling. Filtering is rated for the second environment (industrial supplies with their own transformer). On a network shared with residential or light-commercial loads, additional filtering is required. The graphical local control panel gives plain-language readout, and copies a commissioned parameter set from one drive to the next — the fastest way to roll out a repeated machine build or replace a failed unit. Danfoss drives are configured rather than stocked as fixed catalogue items: the type code FC-202P7K5T2E20H2XGXXXXSXXXXAXBXCXXXXDX describes this exact build, and 131F7536 is the quick order number Danfoss issues for it. Other valid configurations can be built to order.
  • Designed for water and wastewater applications with dedicated pump control functions.
  • Controls centrifugal, displacement, and eccentric screw pumps with quadratic or constant load torque.
  • Integrated cascade controller for automatic pump management and master/follower operation.
  • IP20 chassis enclosure with RFI filter for reliable operation in control cabinets.
  • Features burst pipe monitoring, dry-running protection, and flow compensation.

Specifications

Braking
No brake chopper included
C option software
standard controller
Continuous Amps
30.8
Enclosure
IP20
Enclosure
IP-20 PROTECTED CHASSIS
Enclosure Code
E20
Frame Size
B3
Hardware option A
Standard cable entries
Horsepower
10 HP
LCP Display
Graphical local control panel
PCB Coating
No coated PCB
Phases and main voltage
Three phase 200-240V
Power Code
P7K5
Power size
7.5 kW / 10 HP
Product Line
Pump Drive 230V 3 Phase
Product Line
VLT® AQUA Drive FC 202
RFI filter
No additional EMC filter. Fulfill EN 55011 Class A2 and EN/IEC 61800-3 Category 3
Series
FC202
Type Code
FC-202P7K5T2E20H2XGXXXXSXXXXAXBXCXXXXDX
Voltage
230V 3 Phase
Package Dimensions (L x W x H)
262 mm x 225 mm x 399 mm
Package Weight (Imperial)
11.01 kgs
600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz

CRX0011AC

600V Class Iron Core Reactor, Core and Coil, 11 Amps, 2.57 Inductance, 60 Hz
Double plastic fiber optic, Qty 1, 5 meters long

61059113

Double plastic fiber optic, Qty 1, 5 meters long
The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.

FENA-21

The FENA 21 DualPort module supports Three protocols Modbus-TCP, EtherNet/IP, and the PROFInet IO RT network. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. PROFInet IO RT is an open network based on the PI Organization standard.
KDR, 208V, 19A, 5HP

KDRB22L

KDR, 208V, 19A, 5HP

Frequently Asked Questions

What is the operating voltage range?

The VLT® AQUA Drive operates on 24V DC with a range of 20-28V DC.

What is the temperature range for operation?

The VLT® AQUA Drive can operate in ambient temperatures from -13 to 122°F without derating.

What safety features are included?

The VLT® AQUA Drive includes application and pump protection features such as water hammer reduction, no flow and dry-run protection, and advanced minimum speed monitoring.

How does the back-channel cooling system work?

The back-channel cooling system efficiently removes up to 90% of heat from the drive, reducing the need for air conditioning and lowering installation costs.

What are the installation requirements?

The VLT® AQUA Drive supports direct outdoor installation with an IP66/NEMA 4X protection rating and can accommodate long cable lengths up to 150 m screened and 300 m unscreened.

What maintenance is required for the VLT® AQUA Drive?

The VLT® AQUA Drive is designed for a minimum of 10 years' lifetime with reduced need for routine scheduled replacements due to its high-quality components and intelligent heat management.

What is the energy saving potential?

The VLT® AQUA Drive can deliver energy savings of up to 15% of your investment annually, in addition to savings from adjusting pump speeds to varying loads.

What are the enclosure options available?

The VLT® AQUA Drive is available in various enclosure sizes and protection ratings from IP00 to IP66, suitable for different installation environments.

How does the deragging function work?

The deragging function performs regular or load-triggered wash cycles to keep impellers clean, ensuring consistently high pump efficiency.

Is the VLT® AQUA Drive compatible with various motor technologies?

Yes, the VLT® AQUA Drive automatically adapts to different motor technologies to ensure efficient performance.

Frequently Asked Questions about Danfoss

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What certifications and standards do Danfoss products comply with?

Danfoss products meet an extensive range of international certifications and standards, including EU directives (CE mark), mechanical standards, functional safety standards, and regional certifications. Key certifications include CE marking covering Low Voltage, EMC, Machinery, ErP, ATEX, and RoHS directives; mechanical standards like EN 60529 and UL 50; functional safety standards such as EN 61800-5-2 and IEC 61508; and regional certifications including cULus (North America), UKCA (UK), EAC (Russia), and C-Tick (Australia & New Zealand).

What communication protocols do Danfoss products support?

Danfoss products support a comprehensive range of communication protocols including PROFIBUS DP V1, PROFINET with dual port, EtherNet/IP with dual port, CANopen, DeviceNet, and Modbus RTU (integrated as standard). Additional protocols supported include Modbus TCP, BACnet (MS/TP and IP), EtherCAT, PowerLink, LonWorks, AS interface, and Siemens FLN P1. The specific protocols available vary by product line, with VLT®, VACON®, iC7, and iC2 drives offering extensive fieldbus independence to integrate seamlessly into various automation systems.

What certifications and standards do Danfoss products comply with?

Danfoss products comply with a comprehensive range of certifications and standards including EU directives (CE mark covering Low Voltage, EMC, Machinery, ErP, ATEX, RoHS, and Radio Equipment directives), mechanical standards (EN 60529 IP code, UL 50), functional safety standards (EN 61800-5-2, EN ISO 13849-1, EN 62061, IEC 61508), and ecodesign standards (IEC 61800-9-2). Regional certifications include cULus (North America), UKCA (United Kingdom), EAC (Russia), C-Tick (Australia & New Zealand), TÜV (European safety), and compliance with REACH directive for chemical restrictions.

What industries and applications are Danfoss products used for?

Danfoss products are used across several key industries including HVAC, Food and Beverage, Packaging, Water and Wastewater, Refrigeration, and Marine applications. Their drives and automation solutions serve a wide range of applications such as pumps, fans, compressors, conveyors, process and material treatment equipment, mills, drums, kilns, winding/unwinding systems, drilling equipment, propulsion systems, winches, and power conversion for generation and smart grids. Danfoss has particular expertise in marine applications with over 40 years of experience, providing solutions for ship owner-operators, shipyards, system integrators, and OEMs.

What are the key features of Danfoss products?

Key features of Danfoss products include integrated design elements (harmonics, EMC design, DC choke, and EMC filter) that save installation time and panel space while improving reliability. Installation and setup features include removable terminals, USB ports for easy PC connection, application setup wizards, and optional memory modules for convenient parameter transfer. Safety and control features encompass integrated Safe Torque Off (STO) dual channel functionality, control algorithms that run both induction and PM motors, and integrated brake choppers for drives up to 22 kW. Additional operational benefits include side-by-side mounting without derating, operation up to 45°C without derating, and robust construction designed for maximum uptime and efficiency across various industrial applications.

What environmental ratings do Danfoss products have?

Danfoss products offer various environmental protection ratings to meet different application requirements. Their VLT drive series are available in IP00 (Chassis), IP20 (Protected chassis), IP21 (NEMA Type 1), IP54 (NEMA Type 12), IP55, and IP66 (NEMA 4X) ratings. These ratings provide protection ranging from basic chassis protection to dust-tight and water-resistant enclosures suitable for both indoor and outdoor applications, with NEMA 4X/IP66 offering the highest level of protection against windblown dust, rain, splashing water, and external ice formation.

What accessories are available for Danfoss products?

Danfoss offers an extensive range of accessories for their VLT® drive products, organized into several categories: Fieldbus options (including PROFIBUS, DeviceNet, CANopen, PROFINET, Ethernet/IP, and Modbus TCP communication cards), I/O and feedback options (such as general purpose I/O, encoder input, relay cards, and sensor input modules), safety options (including Safe PLC I/O and PTC thermistor cards), motion control options (position controllers and synchronizing controllers), power options (brake resistors and various filters), and other accessories like mounting kits, USB cables, and IP rating conversion kits. These accessories are designed to be installed in specific option slots (A, B, C, and D) on the drives to add extra features and tailor the drive to specific application needs.

What are the main product lines offered by Danfoss?

Danfoss offers several main product lines including: Danfoss Drives (featuring VLT® and VACON® variable frequency drives, plus iC7 and iC2-Micro series), Industrial Automation solutions (sensors, switches, and fluid controls), Danfoss Semco firefighting systems, Sondex® Heat Exchangers, Hydronic Balancing and Control valves, Power Solutions (hydraulic components and PLUS+1® controllers), High Pressure Pumps for seawater applications, Industrial Refrigeration components, and Danfoss IXA emission gas measurement sensors. These product lines serve diverse industries including marine, HVAC, food and beverage, water treatment, and heavy industrial applications.

What is Danfoss's warranty policy?

Danfoss offers standard factory warranty coverage for drives that covers product failures due to defects in materials or workmanship. For new drives, they provide 2-6 year DrivePro Extended Warranty options with factory repair (including parts, labor, and return shipping) and onsite service (covering parts, labor, and travel costs up to $1,000 per incident). They also offer DrivePro-tection warranty that extends coverage to line and load anomalies, accidental moisture exposure, physical damage, and normal wear, though it excludes vandalism, misapplication, and natural disasters. However, the complete warranty terms and conditions are available on their website at www.danfossdrives.com.