ABB - Low Voltage Drives RCRO-01 - The second relay output module can be used in applications where the analog output from the drive is converted to a relay output. Max relay switching voltage: 250 VAC/220 VDC. Max relay switching current: 1A. Max input voltage: +/- 50 VDC. Environmental: -10 degC to +50degC. Conformity: IP00, UL94V-0.
ABB - Low Voltage Drives

RCRO-01

Alternate Item Number: 3AUA0000135609

UPC: 662348077061

Contact for Pricing

Overview

The ABB RCRO-01 Relay Output Module (SKU: RCRO-01) is engineered to bridge the gap between analog drive outputs and essential relay control signals in industrial automation. This module efficiently converts analog signals from ABB low-voltage drives into reliable relay outputs, facilitating precise control and monitoring in diverse applications. Key specifications include a maximum relay switching voltage of 250 VAC or 220 VDC, with a maximum switching current of 1A. The input voltage tolerance is +/- 50 VDC, and the module operates reliably within an ambient temperature range of -10°C to +50°C. Environmental compliance is met with IP00 protection and UL94V-0 flammability rating, ensuring safety and suitability for various industrial settings. This module is ideal for applications requiring the conversion of drive status, such as frequency, output current, output voltage, or DC terminal voltage, into discrete relay signals. It supports the functionality of multifunctional relay terminals, offering both Normally Open (N.O.) and Normally Closed (N.C.) contacts. The module's design aligns with ABB's commitment to robust and dependable drive accessories, ensuring consistent performance in demanding industrial environments. For integration with ABB's MR Series I/O modules, the RCRO-01 is a valuable addition. While the RCRO-01 itself is an output module, it complements systems that may utilize modules like the CBO 10-P for expanded binary output capabilities or interface relays like the RA4 for specific control voltage requirements. The RCRO-01's ability to translate analog drive feedback into actionable relay outputs makes it a critical component for advanced process control, machinery automation, and system monitoring where direct analog-to-digital relay conversion is necessary. Trust ABB's expertise in low-voltage drive technology for reliable and efficient industrial control solutions.
  • Converts analog drive outputs to relay signals
  • Max. relay switching voltage: 250 VAC / 220 VDC
  • Max. relay switching current: 1A
  • Operating temperature: -10°C to +50°C
  • IP00 protection and UL94V-0 conformity
R1 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00. R1 through R4 flange kits can be used with 3rd party UL Type 1 & 12 (NEMA 1 & 12) enclosures.

FMK-A-R1

R1 Flange Mounting Kit for the ACS550 drives allows mounting the drive with the heatsink external to a 3rd party enclosure. Use of the flange kit requires removal of the drive cover, reducing protection to IP00. R1 through R4 flange kits can be used with 3rd party UL Type 1 & 12 (NEMA 1 & 12) enclosures.
MIDGET FUSE DELAY 1A TRM1

WTRM 1

MIDGET FUSE DELAY 1A TRM1
OPT-B9-V:1RO(NO),5pcs of 41-240VAC

181B0307

OPT-B9-V:1RO(NO),5pcs of 41-240VAC
DISCONNECT MODULE for 230V, 2hp

64160029

DISCONNECT MODULE for 230V, 2hp
The FSCA 01 RS-485 Adapter Module supports the Modbus/RTU network protocol. Modbus/RTU is a variant of the Modbus family of simple, vendor neutral communication protocols intended for supervision and control of automation equipment. The Modbus/RTU implementation in the FSCA 01 RS-485 Adapter Module is done according to Modbus Application Protocol Specification v1.1b

FSCA-01

The FSCA 01 RS-485 Adapter Module supports the Modbus/RTU network protocol. Modbus/RTU is a variant of the Modbus family of simple, vendor neutral communication protocols intended for supervision and control of automation equipment. The Modbus/RTU implementation in the FSCA 01 RS-485 Adapter Module is done according to Modbus Application Protocol Specification v1.1b
Analog I/O extension module FIO-11 has three bi-polar current (-20 to +20 mA) or bi-polar voltage (-10 to +10 V) inputs and one uni-polar current (0(4) to 20 mA) output. It also has two 24 VDC digital input/outputs (configurable either as a 50 mA source or 50 mA sink). Analog inputs are 16 bit resolution, outputs are 12 bit. Analog and digital I/O are galvanically isolated as a group, from each other and from the power supply.

FIO-11-KIT

Analog I/O extension module FIO-11 has three bi-polar current (-20 to +20 mA) or bi-polar voltage (-10 to +10 V) inputs and one uni-polar current (0(4) to 20 mA) output. It also has two 24 VDC digital input/outputs (configurable either as a 50 mA source or 50 mA sink). Analog inputs are 16 bit resolution, outputs are 12 bit. Analog and digital I/O are galvanically isolated as a group, from each other and from the power supply.
DriveSPC software 1.x (Win2000/XP/Vista), add-on for DriveStudio, software only.

DRIVESPC-1.5

DriveSPC software 1.x (Win2000/XP/Vista), add-on for DriveStudio, software only.
Digital I/O extension module FIO-01 has four 24 VDC digital input/outputs (configurable either as 50 mA source or 500 mA sink) and two form C (NO/NC) relay outputs (2 Amps at 240 VAC). The I/O is galvanically isolated as a group. Relay outputs have reinforced isolation.

FIO-01-KIT